Sanyo PLC-HF10000L RS232 Expand - Page 85
CR_LAMPH Command, 9.11 CR_LAMPCORRESPH Command, 9.12 CR_LAMPINTERVAL Command, 9.13
View all Sanyo PLC-HF10000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
PLC-HF10000L Expand Serial Command Functional Specifications 9.9.10 CR_LAMPH Command Command "CR_LAMPH" [CR] Details Get Lamp running time (in hours) * return actual lamp running time Acceptable "000_%1_%2_%3_%4" [CR] Lamp 1 data comes first, and then one space, after that lamp 2 data is followed. %1 = lamp No.1 %2 = lamp No.2 %3 = lamp No.3 %4 = lamp No.4 Response %1_%2 %3_%4 In the case of 2-lamps model, % 1 and % 2 are only used There are no % 3 and % 4 e.g.; "00410_00410_00410_00410" [CR Lamp No.1 = 410 Hours Lamp No.2 = 410 Hours Lamp No.3 = 410 Hours Lamp No.4 = 410 Hours Unacceptable "Error Code" [CR] 9.9.11 CR_LAMPCORRESPH Command Command "CR_LAMPCORRESPH" [CR] Details Get Lamp running time (in hours) *return lamp running time multiplied by a coefficient (not actual running time) Acceptable "000_%1" [CR] Response %1 "00000"-"99999" Unacceptable "Error Code" [CR] 9.9.12 CR_LAMPINTERVAL Command Command "CR_LAMPINTERVAL" [CR] Details Get setting status of Lamp interval Acceptable "000_%1" [CR] "0024 24 Hours is selected "0200 200 Hours is selected Response %1 "0500 500 Hours is selected "1000 1000 Hours is selected "2000 2000 Hours is selected "OFF Off is selected Unacceptable "?" [CR] 9.9.13 CR_LAMPLIFECONTRL Command Command "CR_LAMPLIFECONTRL" [CR] Details Get setting status of Lamp life control. (Available only in the normal Power ON status) Acceptable "000_%1" [CR] Response %1 "MODE1 Mode1 is selected "MODE2 Mode2 is selected Unacceptable "Error Code" [CR] 85/105