Sanyo PLC-HF10000L RS232 Expand - Page 39
CF_VPOS Command, 7.14 CF_HSCALE Command
View all Sanyo PLC-HF10000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
PLC-HF10000L Expand Serial Command Functional Specifications 8.7.13 CF_VPOS Command Command "CF_VPOS_%1" [CR] "015 15 "014 14 "001 1 "000 0 %1 " 01 1 Details Response " 14 14 " 15 15 "UP Increment setting value of Vposition by 1 "DN Decrement setting value of Vposition by 1 Set V Position (Available only in the normal Power ON status) *When selected screen mode is a setting except Custom, return "101" [CR] and the command is not executed. * When input is no signal, return "101" [CR] and the command is not executed. Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.7.14 CF_HSCALE Command Command "CF_HSCALE_%1" [CR] "035 35 "031 31 "002 2 "001 1 "000 0 %1 " 01 1 " 02 2 Details Response " 31 31 " 32 32 "UP Increment setting value of Hscale by 1 "DN Decrement setting value of Hscale by 1 Set Hscale (Available only in the normal Power ON status) *When selected screen mode is a setting except Custom, return "101" [CR] and the command is not executed. * When input is no signal, return "101" [CR] and the command is not executed. Acceptable "000" [CR] Unacceptable "Error Code" [CR] 39/105