PLC-HF10000L Expand Serial Command Functional Specifications 9.7.5 CR_MODELIST Command Command "CR_MODELIST" [CR] Details Get possible modes for Mode list Acceptable "000_%1_%2_---_%x" [CR] Error Code "101" is returned except for PC-Analog and for no signal with PC-Analog Possible modes in Mode1-10 are returned when PC-Analog signal is coming. Response %1 Unacceptable "MODE1" "MODE2" "MODE3" : : "MODE8" "MODE9" "MODE10" "Error Code" [CR] 9.7.6 CR_SRCINP1 Command Command "CR_SRCINP1" [CR] Details Get Source of Input1 Acceptable "000_%1" [CR] "DIGITAL in Computer mode "ANALOG in Computer mode "VIDEO in Video mode "S-VIDEO in Video mode "YPBPR in Component mode "SDI1 in DF-SDI1 mode "SDI2 in DF-SDI2 mode "HDCP in HDCP mode "SCART in SCART mode Response %1 "HDMI in HDMI mode "LINKA-YCBCR" -------- in LINK-A(YCBCR1) mode "LINKB-YCBCR" -------- in LINK-B(YCBCR1) mode "DUAL-YCBCR1" --------- in DUAL(YCBCR1) mode "DUAL-YCBCR2" -------- in DUAL(YCBCR2) mode "DUAL-YCBCR3" -------- in DUAL(YCBCR3) mode "DUAL-YCBCR4" -------- in DUAL(YCBCR4) mode "DUAL-RGB1" -------- in DUAL(RGB1) mode "DUAL-RGB2" -------- in DUAL(RGB2) mode "BLANK There is no input source "NOCARD There is no board inserted Unacceptable "?" [CR] 9.7.7 CR_SRCINP2 Command Command "CR_SRCINP2" [CR] Details Get Source of Input 2 Acceptable "000_%1" [CR] Response %1 The same data as CF_SRCINP1 Unacceptable "?" [CR] 76/105