Sanyo PLC-HF10000L RS232 Expand - Page 97

CR_BLENDTESTPAT Command, 10.44 CR_COLORMATCHING Command, 10.45 CR_CMMSXY_%1 Command, 10.46

Page 97 highlights

PLC-HF10000L Expand Serial Command Functional Specifications 9.10.43 CR_BLENDTESTPAT Command Command "CR_BLENDTESTPAT" [CR] Details Get setting status of Test pattern of Edge blending Acceptable "000_%1" [CR] Response %1 "ON On is selected "OFF Off is selected Unacceptable "Error Code" [CR] 9.10.44 CR_COLORMATCHING Command Command "CR_COLORMATCHING" [CR] Details Get setting status of Color matching Acceptable "000_%1" [CR] Response %1 "ON On is selected "OFF Off is selected Unacceptable "Error Code" [CR] 9.10.45 CR_CMMSXY_%1 Command Command "CR_CMMSXY_%1" [CR] Details Get "x","y" value of Measured of Color matching Acceptable "000_%2_%3" [CR] "RED value of Red is selected %1 "GREEN value of Green is selected Response "BLUE value of Blue is selected %2 "0000"-"1000 x" value of color of %1 %3 "0000"-"1000 y" value of color of %1 Unacceptable "Error Code" [CR] 9.10.46 CR_CMMSL_%1 Command Command "CR_CMMSL_%1" [CR] Details Get "L" value of Measured of Color matching Acceptable "000_%2" [CR] "RED value of Red is selected %1 "GREEN value of Green is selected Response "BLUE value of Blue is selected %2 "0000"-"1000 L" value of color of %1 Unacceptable "Error Code" [CR] 97/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF10000L
Expand Serial Command Functional Specifications
97/105
9.10.43 CR_BLENDTESTPAT Command
Command
“CR_BLENDTESTPAT” [CR]
Details
Get setting status of Test pattern of Edge blending
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------- On is selected
“OFF” --------------------- Off is selected
Response
Unacceptable
“Error Code” [CR]
9.10.44 CR_COLORMATCHING Command
Command
“CR_COLORMATCHING” [CR]
Details
Get setting status of Color matching
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------- On is selected
“OFF” --------------------- Off is selected
Response
Unacceptable
“Error Code” [CR]
9.10.45 CR_CMMSXY_%1 Command
Command
“CR_CMMSXY_%1” [CR]
Details
Get “x”,”y” value of Measured of Color matching
Acceptable
“000_%2_%3” [CR]
%1
“RED” ---------------------- value of Red is selected
“GREEN” ----------------- value of Green is selected
“BLUE” -------------------- value of Blue is selected
%2
“0000”-”1000”------------ “x” value of color of %1
%3
“0000”-”1000”------------ “y” value of color of %1
Response
Unacceptable
“Error Code” [CR]
9.10.46 CR_CMMSL_%1 Command
Command
“CR_CMMSL_%1” [CR]
Details
Get “L” value of Measured of Color matching
Acceptable
“000_%2” [CR]
%1
“RED” ---------------------- value of Red is selected
“GREEN” ----------------- value of Green is selected
“BLUE” -------------------- value of Blue is selected
%2
“0000”-”1000”------------ “L” value of color of %1
Response
Unacceptable
“Error Code” [CR]