Sanyo PLC-HF10000L RS232 Expand - Page 37

CF_CORNER-DL Command, 7.7 CF_CORNER-DR Command, 7.8 CF_CORNERTESTPAT Command, 7.9

Page 37 highlights

PLC-HF10000L Expand Serial Command Functional Specifications 8.7.6 CF_CORNER-DL Command Command "CF_CORNER-DL%1"[CR] "UP Correct the horizontal line of image upwards %1 "DN Correct the horizontal line of image downwards "LEFT" --------- Correct the vertical line of image to the left "RIGHT" ------- Correct the vertical line of image to the right Details Correct the bottom-left corner of the image. (Available in normal Power ON status only) The correction starts with the first command received Projector returns error code ""101 and no operation is made when exceeding the correction limit. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.7.7 CF_CORNER-DR Command Command "CF_CORNER-DR_%1"[CR] "UP Correct the horizontal line of image upwards %1 "DN Correct the horizontal line of image downwards "LEFT" --------- Correct the vertical line of image to the left "RIGHT" ------- Correct the vertical line of image to the right Details Correct the bottom-right corner of the image. (Available in normal Power ON status only) The correction starts with the first command received Projector returns error code ""101 and no operation is made when exceeding the correction limit. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.7.8 CF_CORNERTESTPAT Command Command "CF_CORNERTESTPAT_%1"[CR] "RED Select Red %1 "WHITE" -------- Select White "BLUE Select Blue "OFF Select Off Details Display test patterns for Corner correction. (Available in normal Power ON status only) The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.7.9 CF_KEYSTONEMODE Command Command "CF_KYSTNMODE _%1" [CR] %1 "STR" --------- Set Keystone store mode to Store "RST" --------- Set Keystone store mode to Reset Details Set Keystone store mode (Available only in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 37/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF10000L
Expand Serial Command Functional Specifications
37/105
8.7.6 CF_CORNER-DL Command
Command
“CF_CORNER-DL%1”[CR]
%1
“UP” ------------ Correct the horizontal line of image upwards
“DN” ------------ Correct the horizontal line of image downwards
“LEFT” --------- Correct the vertical line of image to the left
“RIGHT” ------- Correct the vertical line of image to the right
Details
Correct the bottom-left corner of the image.
(Available in normal Power ON status only)
The correction starts with the first command received
Projector returns error code “”101 and no operation is made when exceeding the
correction limit.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.7 CF_CORNER-DR Command
Command
“CF_CORNER-DR_%1”[CR]
%1
“UP” ------------ Correct the horizontal line of image upwards
“DN” ------------ Correct the horizontal line of image downwards
“LEFT” --------- Correct the vertical line of image to the left
“RIGHT” ------- Correct the vertical line of image to the right
Details
Correct the bottom-right corner of the image.
(Available in normal Power ON status only)
The correction starts with the first command received
Projector returns error code “”101 and no operation is made when exceeding the
correction limit.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.8 CF_CORNERTESTPAT Command
Command
“CF_CORNERTESTPAT_%1”[CR]
%1
“RED” ------------Select Red
“WHITE” -------- Select White
“BLUE” ---------- Select Blue
“OFF” ------------ Select Off
Details
Display test patterns for Corner correction.
(Available in normal Power ON status only)
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.7.9 CF_KEYSTONEMODE Command
Command
“CF_KYSTNMODE _%1” [CR]
%1
“STR” --------- Set Keystone store mode to Store
“RST” --------- Set Keystone store mode to Reset
Details
Set Keystone store mode (Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]