Sanyo PLC-HF10000L RS232 Expand - Page 59

CF_KEYDIS Command, 9.58 CF_SHUTRCPROT Command, 9.59 CF_SHUTKEYPROT Command, 9.60 CF_SHUTH

Page 59 highlights

PLC-HF10000L Expand Serial Command Functional Specifications 8.9.57 CF_KEYDIS Command Command "CF_KEYDIS_%1" [CR] "NONE RC & KEY are valid %1 "RC RC is invalid "KEY KEY is invalid Details Set the limitation of RC/KEY use (Valid only when in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.58 CF_SHUTRCPROT Command Command "CF_SHUTRCPROT_%1" [CR] %1 "ON Disable RC key from controlling Shutter (Protection On) "OFF Enable RC key to control Shutter (Protection Off) Details Set valid / invalid of RC use on Shutter control function (Valid only when in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.59 CF_SHUTKEYPROT Command Command "CF_SHUTKEYPROT_%1" [CR] %1 "ON" --------- Disable key on the side panel from controlling Shutter (Protection On) "OFF" -------- Enable key on the side panel to control Shutter (Protection Off) Details Set valid / invalid use of key on the top panel on Shutter control function. (Valid only when in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.60 CF_SHUTH Command Command "CF_SHUTH_%1" [CR] "005"-"480"----------Specify setting time directly %1 "UP Add 1 minute "DN Decrease 1 minute Details Set time of operating shutter management function. (Valid only when in the normal Power ON status) The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 59/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF10000L
Expand Serial Command Functional Specifications
59/105
8.9.57 CF_KEYDIS Command
Command
“CF_KEYDIS_%1” [CR]
%1
“NONE” ------------------------- RC & KEY are valid
“RC” ----------------------------- RC is invalid
“KEY” --------------------------- KEY is invalid
Details
Set the limitation of RC/KEY use (Valid only when in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.58 CF_SHUTRCPROT Command
Command
“CF_SHUTRCPROT_%1” [CR]
%1
“ON” ------------------ Disable RC key from controlling Shutter (Protection On)
“OFF” ----------------- Enable RC key to control Shutter (Protection Off)
Details
Set valid / invalid of RC use on Shutter control function
(Valid only when in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.59 CF_SHUTKEYPROT Command
Command
“CF_SHUTKEYPROT_%1” [CR]
%1
“ON” --------- Disable key on the side panel from controlling Shutter (Protection On)
“OFF” -------- Enable key on the side panel to control Shutter (Protection Off)
Details
Set valid / invalid use of key on the top panel on Shutter control function.
(Valid only when in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.60 CF_SHUTH Command
Command
“CF_SHUTH_%1” [CR]
%1
“005”-“480”----------Specify setting time directly
“UP” ------------------ Add 1 minute
“DN” ------------------Decrease 1 minute
Details
Set time of operating shutter management function.
(Valid only when in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]