PLC-HF10000L Expand Serial Command Functional Specifications 9.10.10 CR_P-MANE Command Command "CR_P-MANE" [CR] Details Get setting status of Power management Acceptable "000_%1" [CR] "OFF Power Management is disabled Response %1 "READY Power Management is set to Ready "SHUTDOWN" -----Power Management is set to Shut Down mode Unacceptable "?" [CR] 9.10.11 CR_P-MANETIME Command Command "CR_P-MAETIME" [CR] Details Get setting time for starting Power Management function Acceptable "000_%1" [CR] Response %1 "001 - 030 1 to 30 minutes Unacceptable "?" [CR] 9.10.12 CR_ON-STA Command Command "CR_ON-STA" [CR] Details Get Direct on setting status Acceptable "000_%1" [CR] Response %1 "ON Direct on is set to ON. "OFF Direct on is set to OFF. Unacceptable "?" [CR] 9.10.13 CR_SECURITY Command Command "CR_ SECURITY" [CR] Details Get ON/OFF setting status of Security on menu. Acceptable "000_%1" [CR] Response %1 "ON PJ is locked "OFF PJ is not locked. Unacceptable "Error Code" [CR] 9.10.14 CR_PJLOCKNOW Command Command "CR_PJLOCKNOW" [CR] Details Get actual setting status of PIN code lock Acceptable "000_%1" [CR] "LOCK" ------ PJ is locked PIN code lock is set to ON1/ON2 on the menu and PJ PIN code is not entered, therefore PJ is actually locked. Response %1 "FREE" ------- PJ is unlocked (either A or B) A) PJ lock is set to OFF on the menu B) PJ lock is set to ON1/ON2 on the menu, but PIN code Lock mode is canceled because PJ PIN code is entered. Unacceptable "Error Code" [CR] 88/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF10000L
Expand Serial Command Functional Specifications
88/105
9.10.10 CR_P-MANE Command
Command
“CR_P-MANE” [CR]
Details
Get setting status of Power management
Acceptable
“000_%1” [CR]
%1
“OFF” ------------------------ Power Management is disabled
“READY” -------------------- Power Management is set to Ready
“SHUTDOWN” -----Power Management is set to Shut Down mode
Response
Unacceptable
“?” [CR]
9.10.11 CR_P-MANETIME Command
Command
“CR_P-MAETIME” [CR]
Details
Get setting time for starting Power Management function
Acceptable
“000_%1” [CR]
%1
“001 – 030” ----------------------- 1 to 30 minutes
Response
Unacceptable
“?” [CR]
9.10.12 CR_ON-STA Command
Command
“CR_ON-STA” [CR]
Details
Get Direct on setting status
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- Direct on is set to ON.
“OFF” ------------------------ Direct on is set to OFF.
Response
Unacceptable
“?” [CR]
9.10.13 CR_SECURITY Command
Command
“CR_ SECURITY” [CR]
Details
Get ON/OFF setting status of Security on menu.
Acceptable
“000_%1” [CR]
%1
“ON” ------------ PJ is locked
“OFF” ----------- PJ is not locked.
Response
Unacceptable
“Error Code” [CR]
9.10.14 CR_PJLOCKNOW Command
Command
“CR_PJLOCKNOW” [CR]
Details
Get actual setting status of PIN code lock
Acceptable
“000_%1” [CR]
%1
“LOCK” ------ PJ is locked
PIN code lock is set to ON1/ON2 on the menu and PJ PIN
code is not entered, therefore PJ is actually locked.
“FREE” ------- PJ is unlocked (either A or B)
A) PJ lock is set to OFF on the menu
B) PJ lock is set to ON1/ON2 on the menu, but PIN code Lock
mode is canceled because PJ PIN code is entered.
Response
Unacceptable
“Error Code” [CR]