Sanyo PLC-HF10000L RS232 Expand - Page 87
CR_LOGO Command, 10.6 CR_LOGOLOCK Command, 10.7 CR_FANSPEED Command, 10.8 CR_RCODE Command, 10.
View all Sanyo PLC-HF10000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
PLC-HF10000L Expand Serial Command Functional Specifications 9.10.5 CR_LOGO Command Command "CR_LOGO" [CR] Details Get Logo setting status Acceptable "000_%1" [CR] "DFLT Default Logo is enabled Response %1 "USER User is enabled "OFF Off is enabled Unacceptable "?" [CR] 9.10.6 CR_LOGOLOCK Command Command "CR_LOGOLOCK" [CR] Details Get setting status of Logo Lock function Acceptable "000_%1" [CR] Response %1 "ON Logo Lock is ON "OFF Logo Lock is OFF Unacceptable "Error Code" [CR] 9.10.7 CR_FANSPEED Command Command "CR_FANSPEED" [CR] Details Get currently selected Fan Control Speed Acceptable "000_%1" [CR] Response %1 "MAX Max speed of Fan Control is selected "NOR Normal speed of Fan Control is selected Unacceptable "?" [CR] 9.10.8 CR_RCODE Command Command "CR_RCODE" [CR] Details Get currently selected Remote Control code Acceptable "000_%1" [CR] "001 Code1 "002 Code2 Response %1 : "007 Code7 "008 Code8 Unacceptable "?" [CR] 9.10.9 CR_RSENS Command Command "CR_RSENS" [CR] Details Get selected location of infrared remote receiver of remote control Acceptable "000_%1" [CR] "BOTH" --------Select both front and back receiver of projector Response %1 "FRONT" ----- Select only front receiver of projector "BACK" ------- Select only back receiver of projector Unacceptable "?" [CR] 87/105