Sharp PN-Y556 PN-Y326 PN-Y436 PN-Y496 PN-Y556 Operation Manual - Page 37

Controlling the Monitor with a computer RS-232C, Commands for ID control

Page 37 highlights

Controlling the Monitor with a computer (RS-232C) nCommands for ID control The command examples shown on this page assume the following connection and ID SETTING. ID number: 1 ID number: 2 ID number: 3 ID number: 4 IDLK The parameter of this command sets the ID number of the monitor. The monitor is subject to all subsequent commands. Example: IDST A monitor receiving this command sets its own ID number in the parameter field. Example: IDST0001 OK 001 ← The ID number of this monitor is set to 1. TIPS You can automatically assign ID numbers by using the IDST command with the Repeater control (see "Repeater control" on page 38). For example, using the command "IDST001+" automatically sets the ID numbers, as shown below. [Example] ID number: 1 ID number: 2 ID number: 3 ID number: 4 IDST001 + WAIT OK 001 OK 002 OK 003 OK 004 ← ID setting command with repeater control ← "OK" response from ID number: 1 ← "OK" response from ID number: 2 ← "OK" response from ID number: 3 ← "OK" response from ID number: 4 (End) IDLK0002 ← The next command is for the monitor with ID number: 2. WAIT ← Searching for monitor with ID number: 2 OK 002 ← Found monitor with ID number: 2 VOLM0030 ← Sets volume of monitor with ID number: 2 to 30.* WAIT ← Processing OK 002 VOLM0020 ← Sets volume of monitor with ID number: 2 to 20.* WAIT OK 002 IDLK0000 ← Canceling fixed ID number setting WAIT ← Canceling IDLK OK 002 ← Cancelation complete VOLM0010 The volume of the monitor with ID number: OK 001 ← 1 (the one directly connected to the computer) is set to 10. (IDLK is canceled.) * The IDLK command remains effective until it is canceled, or power is shut off. IDSL The parameter of this command sets the ID number of the monitor. The monitor is subject to the next command. Example: IDSL0002 ← The next command is for the monitor with ID number: 2. WAIT ← Searching for monitor with ID number: 2 OK 002 ← Found monitor with ID number: 2 VOLM0030 ← Sets volume of monitor with ID number: 2 to 30. WAIT ← Processing OK 002 ← OK response from monitor with ID number: 2 VOLM0020 ← Sets volume to 20. The volume of the monitor with ID OK 001 ← number: 1 (the one directly connected to the computer) is set to 20.* * The IDSL command is effective only once, for the immediately succeeding command. 37 E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53

37
E
Controlling the Monitor with a computer (RS-232C)
n
Commands for ID control
The command examples shown on this page assume the
following connection and ID SETTING.
ID number: 1
ID number: 2
ID number: 3
ID number: 4
IDST
........
.A monitor receiving this command sets its own ID
number in the parameter field.
Example:
IDST0001
OK
001
The ID number of this monitor is set to 1.
TIPS
You can automatically assign ID numbers by using the IDST
command with the Repeater control (see “Repeater control”
on page 38).
For example, using the command “IDST001+” automatically
sets the ID numbers, as shown below.
[Example]
ID number: 1
ID number: 2
ID number: 3
ID number: 4
IDST001 +
ID setting command with repeater control
WAIT
OK
001
“OK” response from ID number: 1
OK
002
“OK” response from ID number: 2
OK
003
“OK” response from ID number: 3
OK
004
“OK” response from ID number: 4 (End)
IDSL
........
The parameter of this command sets the ID number
of the monitor. The monitor is subject to the next
command.
Example:
IDSL0002
The next command is for the monitor
with ID number: 2.
WAIT
Searching for monitor with ID number:
2
OK
002
Found monitor with ID number: 2
VOLM0030
Sets volume of monitor with ID
number: 2 to 30.
WAIT
Processing
OK
002
OK response from monitor with ID
number: 2
VOLM0020
Sets volume to 20.
OK
001
The volume of the monitor with ID
number: 1 (the one directly connected
to the computer) is set to 20.*
*
The IDSL command is effective only once, for the
immediately succeeding command.
IDLK
........
The parameter of this command sets the ID
number of the monitor. The monitor is subject to all
subsequent commands.
Example:
IDLK0002
The next command is for the monitor
with ID number: 2.
WAIT
Searching for monitor with ID number:
2
OK
002
Found monitor with ID number: 2
VOLM0030
Sets volume of monitor with ID
number: 2 to 30.*
WAIT
Processing
OK
002
VOLM0020
Sets volume of monitor with ID
number: 2 to 20.*
WAIT
OK
002
IDLK0000
Canceling fixed ID number setting
WAIT
Canceling IDLK
OK
002
Cancelation complete
VOLM0010
OK
001
The volume of the monitor with ID number:
1 (the one directly connected to the
computer) is set to 10. (IDLK is canceled.)
*
The IDLK command remains effective until it is
canceled, or power is shut off.