Controlling the Projector Using RS-232C or Telnet Disconnecting All Connections ([D]Disconnect All) It is possible to disconnect all the TCP/IP connections currently recognized by the projector. Even if the COM Redirect port is fixed in the Busy status due to a problem, it is possible to force the Ready status back by carrying out this disconnection. setup>d 1 Disconnect All Connections(y/n)?y 2 Now Disconnecting... 1 Enter "d" and press the "Enter" key. 2 Enter "y" and press the "Enter" key. Note • If Disconnect All is performed, the connection to the projector via network will be forcibly disconnected. Entering ADVANCED SETUP MENU ([A]Advanced Setup) Enters ADVANCED SETUP MENU. setup>a 1 ADVANCED SETUP MENU [1]Auto Logout Time [2]Data Port [5]Network Ping Test [6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3) [9]Accept All IP Addr [0]Search Port [!]Restore Default Setting [Q]Return to Main Menu advanced> 1 Enter "a" and press the "Enter" key. Setting Auto Logout Time (ADVANCED[1]Auto Logout Time) If there is no input after a fixed time, the projector automatically disconnects network connection using the Auto Logout function. It is possible to set the time until the projector is automatically disconnected in units of a minute (from 1 to 65535 minutes). advanced>1 1 Valid range : 0 to 65535 (minute) note: if you enter "0", auto logout function will be disable. Auto Logout Time : 5 Please Enter :15 2 (change) -> 15 * 1 Enter "1" and press the "Enter" key. 2 Enter numerical value and press the"Enter"key. Display set numerical value (*). Note • If the set value is made 0, the Auto Logout function is disabled. • If an invalid number is entered, an error message ("Parameter Error!") will be displayed and returns the ADVANCED SETUP MENU. Data Port Setting (ADVANCED[2]Data Port) Setting of TCP port number can be set in the range of 1025 to 65535. advanced>2 1 Valid range :1025 to 65535 Data Port :10002 Please Enter :10005 2 (change) -> 10005 * 1 Enter "2" and press the "Enter" key. 2 Enter numerical value and press the"Enter"key. Display set numerical value (*). Note • Set according to need. Normally, use with the factory default setting. -24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

-24
Controlling the Projector Using RS-232C or Telnet
Disconnecting All Connec-
tions
([D]Disconnect All)
It is possible to disconnect all the TCP/IP connec-
tions currently recognized by the projector. Even if
the COM Redirect port is fixed in the Busy status
due to a problem, it is possible to force the Ready
status back by carrying out this disconnection.
1
Enter “d” and press the “Enter” key.
2
Enter “y” and press the “Enter” key.
Note
If Disconnect All is performed, the connection to
the projector via network will be forcibly discon-
nected.
Entering ADVANCED
SETUP MENU
([A]Advanced Setup)
Enters ADVANCED SETUP MENU.
1
Enter “a” and press the “Enter” key.
Setting Auto Logout Time
(ADVANCED[1]Auto Logout Time)
If there is no input after a fixed time, the projector
automatically disconnects network connection using
the Auto Logout function. It is possible to set the time
until the projector is automatically disconnected in
units of a minute (from 1 to 65535 minutes).
1
Enter “1” and press the “Enter” key.
2
Enter numerical value and press the “Enter” key.
Display set numerical value (*).
Note
If the set value is made 0, the Auto Logout func-
tion is disabled.
If an invalid number is entered, an error message
(“Parameter Error!”) will be displayed and returns
the ADVANCED SETUP MENU.
Data Port Setting
(ADVANCED[2]Data Port)
Setting of TCP port number can be set in the range
of 1025 to 65535.
1
Enter “2” and press the “Enter” key.
2
Enter numerical value and press the “Enter” key.
Display set numerical value (*).
Note
Set according to need. Normally, use with the fac-
tory default setting.
setup>d
Disconnect All Connections(y/n)?y
Now Disconnecting...
1
2
setup>a
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time
[2]Data Port
[5]Network Ping Test
[6]Accept IP Addr(1)
[7]Accept IP Addr(2)
[8]Accept IP Addr(3)
[9]Accept All IP Addr
[0]Search Port
[!]Restore Default Setting
[Q]Return to Main Menu
advanced>
1
advanced>1
Valid range
: 0 to 65535 (minute)
note: if you enter “0”, auto logout function will be disable.
Auto Logout Time : 5
Please Enter
:15
(change)
—> 15
1
2
*
advanced>2
Valid range
:1025 to 65535
Data Port
:10002
Please Enter
:10005
(change)
—>
10005
1