Stihl MS 150 C-E Instruction Manual - Page 46
MS 150 TC
View all Stihl MS 150 C-E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
English The following maintenance intervals apply for normal operating conditions only. If your daily working time is longer or operating conditions are difficult (very dusty work area, resin-rich wood, tropical wood, etc.), shorten the specified intervals accordingly. If you only use the saw occasionally, extend the intervals accordingly. before starting work after finishing work or daily after each refueling stop weekly monthly every 12 months if problem if damaged if required Cooling inlets Clean X Cylinder fins Clean X X Carburetor Check idle adjustment - chain must not rotate X X Readjust idle Spark plug Readjust electrode gap Replace after 100 hours of operation All accessible screws and nuts (not adjusting screws) 2) Retighten Check1) Spark arresting screen in muffler (not all markets) Clean, replace if necessary1) Check X Chain catcher Replace Safety labels Replace 1) STIHL recommends a STIHL servicing dealer. 2) Firmly tighten down the cylinder base screws of professional saws (3.4 kW or more) after 10 to 20 hours of operation. X X X X X X X 44 MS 150 TC