Thermador HMWB36WS Installation Instructions - Page 16

Electrical Connection

Page 16 highlights

Electrical Connection WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. • Disconnect power. • Remove terminal box cover. • Remove the knockout in the terminal box cover and install a UL listed or CSA approved 1/2" strain relief. B A Juction Box A B Knockout C Juction Box cover • Use UL listed wire connectors and connect white wires (E) together. WARNING Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. Failure to do so can result in death or electrical shock. • Connect green (or bare) ground wire from home power supply to yellow-green ground wire (F) in terminal box using UL listed wire connectors. • Tighten strain relief screw. • Install terminal box cover. • Reconnect power. C • Run home power supply cable through strain relief, into terminal box. E B A C D F A. Home power supply cable B. UL listed or CSA approved strain relief C. Black wires D. UL listed wire connectors E. White wires F. Green (or bare) and yellow-green ground wires • Use UL listed wire connectors and connect black wires (C) together. English | 16 | Installation Instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Installation Instructions
English | 16 |
Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Disconnect power.
Remove terminal box cover.
Remove the knockout in the terminal box cover and
install a UL listed or CSA approved 1/2” strain relief.
C
A
B
A
Juction Box
B
Knockout
C
Juction Box cover
Run home power supply cable through strain relief,
into terminal box.
A
F
C
E
B
D
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green
ground wires
Use UL listed wire connectors and connect black wires
(C) together.
Use UL listed wire connectors and connect white wires
(E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box. Failure to do so can result in death or
electrical shock.
Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
Tighten strain relief screw.
Install terminal box cover.
Reconnect power.