Thermador HMWB36WS Installation Instructions - Page 9

Installation Preparation

Page 9 highlights

Installation Preparation Installation Considerations Clearances and requirements Hood installation height above a cooktop, rangetop or range can vary. To obtain the necessary installation height above a cooktop, rangetop or range, consult the appliance's installation manual. 45/16" (110) 11" (280) 30" (762) min over a gas cooktop 30" (762) min over an electric cooktop Hood Width The hood width should be no less than the width of the cooking surface. For proper performance, the housing must cover the entire cooking surface. Where space is not restricted, a wider hood can be used to increase capture area. For proper performance, the hood must be centered horizontally above the cooking surface. Distance From Cooking Surface For gas cooktop & range installations: Mount the hood so the bottom is at least 30" (76.2 cm) above the cooking surface. For electric/induction cooktop & range installations: Mount the hood so the bottom is at least 30" (76.2 cm) above the cooking surface. NOTICE: The hood could incur some damage from heat if a THERMADOR MASTERPIECE® series cooktop is operated with multiple burners at high settings under a hood that is installed at minimum clearances. Unit Weight This vent hood is heavy. Adequate structure and support must be provided in all types of installations. When calculating the load for the housing support system, be sure to consider the weight of the ventilation unit. Unit 30'' (76 cm) 36'' (91 cm) Single blower 36'' (91 cm) Dual blower 48'' (122 cm) Weight 40.3 lb (18.3 kg) 42.5 lb (19.3 kg) 54.6 lb (24.8 kg) 65.9 lb (29.9 kg) IMPORTANT: The supplied weights address only the ventilation unit and blower. Installer must account for weight of any materials of construction when calculating the total dead weight load of installation, including but not limited to: wall, tile, mortar, plaster, brick, inishes, partitions, and other similarly incorporated architectural and structural items. It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to speciic installations. Wall Framing Due to the weight of the hood, make sure the wood mounting bracket is attached to all available wall studs. Framing must be fastened together and to ceiling joists to provide enough structural strength to support the weight of the hood and internal blower, if applicable. Wall framing should be, at minimum, made of 2"x 4" lumber. Proper structural support is required to accommodate the weight of the hood. Installation Instructions English | 9 |

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Installation Instructions
English | 9 |
Installation Preparation
Installation Considerations
Clearances and requirements
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the applian-
ce’s installation manual.
11
"
(280)
4
5
/
16
"
(110)
30" (762) min over a gas cooktop
30" (762) min over an electric cooktop
Hood Width
The hood width should be no less than the width of the
cooking surface. For proper performance, the housing
must cover the entire cooking surface. Where space is
not restricted, a wider hood can be used to increase
capture area.
For proper performance, the hood must be centered
horizontally above the cooking surface.
Distance From Cooking Surface
For gas cooktop & range installations: Mount the hood
so the bottom is at least 30” (76.2 cm) above the cooking
surface.
For electric/induction cooktop & range installations:
Mount the hood so the bottom is at least 30” (76.2 cm)
above the cooking surface.
NOTICE:
The hood could incur some damage from heat
if a THERMADOR MASTERPIECE
®
series cooktop is opera-
ted with multiple burners at high settings under a hood that
is installed at minimum clearances.
Unit Weight
This vent hood is heavy. Adequate structure and support
must be provided in all types of installations.
When calculating the load for the housing support
system, be sure to consider the weight of the
ventilation unit.
Unit
Weight
30’’ (76 cm)
40.3 lb (18.3 kg)
36’’ (91 cm) Single blower
42.5 lb (19.3 kg)
36’’ (91 cm) Dual blower
54.6 lb (24.8 kg)
48’’ (122 cm)
65.9 lb (29.9 kg)
IMPORTANT:
The supplied weights address only the ventilation unit and
blower. Installer must account for weight of any materials
of construction when calculating the total dead weight
load of installation, including but not limited to: wall, tile,
mortar, plaster, brick, Inishes, partitions, and other similar
-
ly incorporated architectural and structural items. It is the
responsibility of the owner and the installer to determine if
additional requirements and/or standards apply to speciIc
installations.
Wall Framing
Due to the weight of the hood, make sure the wood moun-
ting bracket is attached to all available wall studs.
Framing must be fastened together and to ceiling joists to
provide enough structural strength to support the weight of
the hood and internal blower, if applicable.
Wall framing should be, at minimum, made of 2”x 4” lum-
ber. Proper structural support is required to accommodate
the weight of the hood.