3. Tests and Diagnostics 3.7 Main Battery Change Test 3.6 Main Battery Charge Test NOTE: The AC adaptor (90W, 19V) should be connected to successfully run this test. This test shows and measures the main battery: Battery type (Lion) Manufacturer (Sanyo/Panasonic/Sony) Remain charge capacity (0 ~ 100%) Charge function (PASS/FAIL) - "Battery Is Full" showed when "remain charge capacities" is 100% The screen should display as below, if the charge function is OK, will show:. If the charge function is NG, the screen will display as: 3-12 Satellite A205/A200 /Satellite Pro A200/EQUIUM A200/ SATEGO A200 Series Maintenance Manual
3.
Tests and Diagnostics
3.7 Main Battery Change Test
3.6 Main Battery Charge Test
NOTE
: The AC adaptor (
90W, 19V
) should be connected to successfully run this test.
This test shows and measures the main battery:
Battery type (Lion)
Manufacturer (Sanyo/Panasonic/Sony)
Remain charge capacity (0 ~ 100%)
Charge function (PASS/FAIL)
- “Battery Is Full” showed when “remain charge capacities” is 100%
The screen should display as below, if the charge function is OK, will show:.
If the charge function is NG, the screen will display as: