Zanussi ZCG551GNC Product Manaul - Page 22
Gas burners
![]() |
View all Zanussi ZCG551GNC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Gas burners BURNER Auxiliary burner Semi-rapid burner Rapid burner Grill Top Oven Main Oven NORMAL POWER kW 1,0 2,0 2,9 2,7 1,9 1,9 NATURAL GAS inj. 100/mm Btu/h 70 3412 96 6483 119 10236 120 9212 99 6483 99 6483 Gas Connection Use a flexible pipe in compliance with the regulation in force. Be careful they do not come in touch with mobile parts or they are not squeezed. Warning! Only a qualified and competent person must do the gas installation. Warning! Before gas connection disconnect the mains plug from the mains socket or switch off the fuse in the fuse box. Close the primary valve of the gas supply. Supply piping should not be less than R3/8. Connection is made to the Rc ½ (1/2 " B.S.P.) female threaded. Entry pipe located just below the hob level on the rear left hand side of the appliance. The gas supply ramp is on the rear side of the appliance. Warning! Only liquid sealants to be used when inlet gas pipe is fitted i.e.: do not use P.T.F.E. sealant tape. When installation is complete. Carry out a gas tightness test and make sure that the seal of each pipe fitting is correct. Important! Use flexible tubing, which comply with BS.669 current edition. A B C E D C Warning! The gas bayonet must be in mark area. Dimension mm A 250 B 680 C 50 D 250 E 580 Pressure test The Rapid injector is used as a pressure test point. 1. Connect the pressure gauge to the Rapid injector. 22 www.zanussi.com
![](/manual_guide/products/zanussi-zcg551gnc-product-manaul-679f1a9/22.png)