Brother International IntelliFax-2600 Service Manual - Page 157
Black and blurred, horizontal stripes
View all Brother International IntelliFax-2600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 157 highlights
Trouble (5) Black and blurred vertical stripes (6) Black and blurred horizontal stripes Action to be taken At the scanner Check the following components: - CIS unit At the printer side Clean the paper path which may be contaminated with toner. Slide the wire cleaner tab to clean the corona wire inside the drum unit. Make sure that the wire cleaner tab is returned to its home position. Replace the drum unit. Replace the heat-fixing unit. At the printer side If the horizontal stripes appear at 94-mm or 17-mm intervals, replace the drum unit. If they appear at 54-mm intervals, replace the heat-fixing unit. (7) White vertical streaks (8) Dropout At the scanner Check the following components: - CIS unit At the printer side Replace the drum unit. At the printer side Check the connection of the main-high-voltage flat cable. Replace the drum unit. Replace the high-voltage power supply PCB. VI - 18