Brother International IntelliFax-2600 Service Manual - Page 40
Control Panel ASSY, the front arrow
View all Brother International IntelliFax-2600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
1.4 Control Panel ASSY (1) Slightly open the control panel ASSY. (2) Push the right and left arms of the control panel ASSY outwards (in the direction of arrow ) with your thumbs and open the control panel ASSY further (arrow ) to unhook those arms from bosses "x" provided on the scanner frame ASSY. Then slide the control panel ASSY to the front (arrow ) to release its bosses "y" from the grooves of the scanner frame ASSY. (3) Slightly lift up the control panel ASSY and disconnect the panel-main harness from the control panel PCB. IV - 8
IV
- 8
1.4
Control Panel ASSY
(1)
Slightly open the control panel ASSY.
(2)
Push the right and left arms of the control panel ASSY outwards (in the direction of arrow
±
)
with your thumbs and open the control panel ASSY further (arrow
²
) to unhook those arms
from bosses “x” provided on the scanner frame ASSY.
Then slide the control panel ASSY to
the front (arrow
³
) to release its bosses “y” from the grooves of the scanner frame ASSY.
(3)
Slightly lift up the control panel ASSY and disconnect the panel-main harness from the control
panel PCB.