Dell PowerStore 3200T EMC PowerStore Installation and Service Guide for PowerS - Page 153

Verify the operation of a replacement Clock Distribution Board, Return a faulted part

Page 153 highlights

Figure 180. Closing the system cover 4. Push the expansion enclosure into the rack. Verify the operation of a replacement Clock Distribution Board Steps 1. From PowerStore Manager, select Hardware. 2. Select the appliance where you replaced the Clock Distribution Board. 3. On the Components card, under Rear View, expand ExpansionEnclosure. 4. Select the relevant Clock Distribution Board. The status of the replacement Clock Distribution Board should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore Manager. If the status does not change, ensure that the Clock Distribution Board is correctly seated, or contact your service provider. Return a faulted part About this task For US customers, return defective material within five business days. For International customers, return defective material within 10 business days. The materials required to return your defective part are supplied with the good part shipment. Steps 1. Package the faulted part in the shipping box that contained the replacement part. 2. Ship the failed part to your service provider as described in the instructions that were included with the replacement part. 3. For more information about returning customer-replaceable parts: a. Open PowerStore Manager. b. Click Settings on the upper right of the screen. c. Click General Support. d. Under Drives, Power Supplies, and Other Parts, click Return Part. e. If your screen does not show the Return Part link, contact your service provider for instructions. NVMe expansion enclosure service procedures 153

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

Figure 180. Closing the system cover
4.
Push the expansion enclosure into the rack.
Verify the operation of a replacement Clock Distribution Board
Steps
1.
From PowerStore Manager, select
Hardware
.
2.
Select the appliance where you replaced the Clock Distribution Board.
3.
On the
Components
card, under
Rear View
, expand
ExpansionEnclosure
.
4.
Select the relevant Clock Distribution Board.
The status of the replacement Clock Distribution Board should read
Healthy
. If the status is still
Faulted
, wait a few
minutes and refresh PowerStore Manager. If the status does not change, ensure that the Clock Distribution Board is
correctly seated, or contact your service provider.
Return a faulted part
About this task
For US customers, return defective material within five business days. For International customers, return defective material
within 10 business days. The materials required to return your defective part are supplied with the good part shipment.
Steps
1.
Package the faulted part in the shipping box that contained the replacement part.
2.
Ship the failed part to your service provider as described in the instructions that were included with the replacement part.
3.
For more information about returning customer-replaceable parts:
a.
Open PowerStore Manager.
b.
Click
Settings
on the upper right of the screen.
c.
Click
General Support
.
d.
Under
Drives, Power Supplies, and Other Parts
, click
Return Part
.
e.
If your screen does not show the Return Part link, contact your service provider for instructions.
NVMe expansion enclosure service procedures
153