Epson ColorWorks CW-C6500A Technical Reference Guide - External I/O CW-C6000/C - Page 17
Commands, List of Commands
View all Epson ColorWorks CW-C6500A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Chapter 3 Commands Commands This section describes the commands of the external I/O. You can acquire each signal's mode settings and printer setting values. List of Commands The signal specifications for the external I/O are as follows. No. Command name category Command function Command and parameters 1 External I/O out- End print signal mode setting put signal settings ^S(CNA,B,c c = D/E/N/0 - 4 0/D: End print signal OFF (End print signal not output) 1: Normal: High, When feeding paper: Low 2/E: Normal: Low, When feeding paper: High 3: Normal: High, For 20 msec after printing: Low 4/N: Normal: Low, For 20 msec after printing: 3 High 2 Data ready signal mode setting ^S(CNA,A,c c= D/E/0/1/2 0/D: Off 1: Normal: High, When an event occurs: Low 2/E: Normal: Low, When an event occurs: High 3 Clogged nozzle detected signal ^S(CNA,D,c mode setting c= D/E/0/1/2 0/D: Off 1: Normal: High, When an event occurs: Low 2/E: Normal: Low, When an event occurs: High 4 Head maintenance mode setting ^S(CNA,M,c c= D/E/0/1/2 0/D: Off 1: Normal: High, When an event occurs: Low 2/E: Normal: Low, When an event occurs: High 5 Printer ready signal mode setting ^S(CNA,O,c c= D/E/0/1/2 0/D: Off 1: Normal: High, When an event occurs: Low 2/E: Normal: Low, When an event occurs: High 6 Warning signal mode setting ^S(CNA,W,c c= D/E/0/1/2 0/D: Off 1: Normal: High, When an event occurs: Low 2/E: Normal: Low, When an event occurs: High 17