Epson ColorWorks CW-C6500A Technical Reference Guide - External I/O CW-C6000/C - Page 62

Perform jumper settings. Pull out the connector jumper pin and insert it into

Page 62 highlights

6 Perform jumper settings. Pull out the connector jumper pin and insert it into the number to be set. Press with your fingers on the right side of the interface board to affix it while pulling and inserting the jumper pin. CN100 CN200 c • When shorting pins 1 and 2 on CN100, DO NOT short pins 2 and 3 on CN200. IMPORTANT • When shorting pins 2 and 3 on CN100, DO NOT short pins 1 and 2 on CN200. State Power supply/SG not separated (Initial setting) Power supply/SG separated CN100 JP setting CN200 JP setting 1-2 pin shorted 1-2 pin shorted 2-3 pin shorted 2-3 pin shorted Jumper pin Once jumper settings are performed, install the covers using the following procedure. 7 Install the internal cover and affix it using the screws (x 4). 8 Install the left side cover and affix it using the screws (x 5). 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

62
6
Perform jumper settings. Pull out the connector jumper pin and insert it into the
number to be set.
Press with your fingers on the right side of the interface board to affix it while pulling and inserting
the jumper pin.
Once jumper settings are performed, install the covers using the following procedure.
7
Install the internal cover and affix it using the screws (x 4).
8
Install the left side cover and affix it using the screws (x 5).
c
IMPORTANT
When shorting pins 1 and 2 on CN100, DO NOT short pins 2 and 3 on CN200.
When shorting pins 2 and 3 on CN100, DO NOT short pins 1 and 2 on CN200.
State
CN100 JP setting
CN200 JP setting
Power supply/SG not separated (Initial setting)
1-2 pin shorted
1-2 pin shorted
Power supply/SG separated
2-3 pin shorted
2-3 pin shorted
CN100
CN200
Jumper pin