Mode setting for clogged nozzle check signal (input) [Format] ^S(CNI,D,c [Parameter] c Description c = Mode setting 0/1 Definition range [Function] Configure the mode setting for the clogged nozzle check signal. Value for parameter c Description 0 Ignore the clogged nozzle check signal (pin 14). 1 Set the clogged nozzle check signal (pin 14) to the following mode: Check the nozzles when a Low signal is input for 20 msec or longer. [Initial value] 0 [Examples of command transmissions] Set the clogged nozzle signal to "Check the nozzles when a Low signal is input for 20 msec or longer". The ^JUS command must be used to save the settings to the non-volatile memory in the printer. An example of the command transmission is shown below. It is sent via USB or Ethernet from the computer. ^XA ^S(CNI,D,1 ^JUS ^XZ 34