Acquisition commands for mode setting values for head cleaning signal (input)
View all Epson ColorWorks CW-C6500A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Chapter 3 Commands Acquisition commands for mode setting values for head cleaning signal (input) [Format] ~H(CNI,C [Parameter] None [Function] Acquire the mode setting values for the head cleaning signal. Return value after executing this command Description 0 Head cleaning signal (pin 15) ignored 1 Head cleaning signal (pin 15) set to clean the head when a Low signal is input for 20 msec or longer Acquisition commands for mode setting values for clogged nozzle check signal (input) [Format] ~H(CNI,D [Parameter] None 3 [Function] Acquire the mode setting values for the clogged nozzle check signal. Return value after executing this command Description 0 Clogged nozzle check signal (pin 14) ignored 1 Clogged nozzle check signal (pin 14) set to check the nozzles when a Low signal is input for 20 msec or longer. Acquisition commands for mode setting values for feed signal (input) [Format] ~H(CNI,F [Parameter] None [Function] Acquire the mode setting values for the feed signal. Return value after executing this command Description 0 Feed signal (pin 11) ignored 1 Feed signal (pin 11) set to feed the label when a Low signal is input for 20 msec or longer 43