Epson ColorWorks CW-C6500A Technical Reference Guide - External I/O CW-C6000/C - Page 33

Mode setting for head cleaning signal (input

Page 33 highlights

Chapter 3 Commands Mode setting for head cleaning signal (input) [Format] ^S(CNI,C,c [Parameter] c Description c = Mode setting 0/1 Definition range [Function] Configure the mode settings for the head cleaning signal. Value for parameter c Description 0 Ignore the head cleaning signal (pin 15). 1 Set the head cleaning signal (pin 15) to the following mode: Clean the head when a Low signal is input for 20 msec or longer. [Initial value] 0 [Examples of command transmissions] 3 Set the head cleaning signal to "Clean the head when a Low signal is input for 20 msec or longer". The ^JUS command must be used to save the settings to the non-volatile memory in the printer. An example of the command transmission is shown below. It is sent via USB or Ethernet from the computer. ^XA ^S(CNI,C,1 ^JUS ^XZ 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

33
Chapter 3
Commands
3
Mode setting for head cleaning signal (input)
[Format]
^S(CNI,C,c
[Parameter] c
[Function]
Configure the mode settings for the head cleaning signal.
[Initial value]
0
[Examples of command transmissions]
Set the head cleaning signal to "Clean the head when a Low signal is input for 20 msec or longer".
The ^JUS command must be used to save the settings to the non-volatile memory in the printer.
An example of the command transmission is shown below. It is sent via USB or Ethernet from the computer.
^XA
^S(CNI,C,1
^JUS
^XZ
Description
Definition range
c = Mode setting
0/1
Value for parameter c
Description
0
Ignore the head cleaning signal (pin 15).
1
Set the head cleaning signal (pin 15) to the following mode:
Clean the head when a Low signal is input for 20 msec or longer.