Epson ColorWorks CW-C6500A Technical Reference Guide - External I/O CW-C6000/C - Page 40
Acquisition commands for mode setting values for printer ready signal (output)
View all Epson ColorWorks CW-C6500A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Acquisition commands for mode setting values for printer ready signal (output) [Format] ~H(CNA,O [Parameter] None [Function] Acquire the mode setting values for the printer ready signal. Return value after executing this command Description 0 Printer ready signal (pin 19) OFF (not output) 1 Printer ready signal (pin 19) set to Normal: High, When printer is ready: Low 2 Printer ready signal (pin 19) set to Normal: Low, When printer is ready: High Acquisition commands for mode setting values for warning signal (output) [Format] ~H(CNA,W [Parameter] None [Function] Acquire the mode setting values for the warning signal. Return value after executing this command Description 0 Warning signal (pin 16) OFF (not output) 1 Warning signal (pin 16) set to Normal: High, When a warning occurs: Low 2 Warning signal (pin 16) set to Normal: Low, When a warning occurs: High Acquisition commands for mode setting values for error signal (output) [Format] ~H(CNA,E [Parameter] None [Function] Acquire the mode setting values for the error signal. Return value after executing this command Description 0 Error signal (pin 17) OFF (not output) 1 Error signal (pin 17) set to Normal: High, When an error occurs: Low 2 Error signal (pin 17) set to Normal: Low, When an error occurs: High 40