Epson ColorWorks CW-C6500A Technical Reference Guide - External I/O CW-C6000/C - Page 42
Acquisition command of mode setting value for paper out signal (input), Acquisition commands
View all Epson ColorWorks CW-C6500A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Acquisition command of mode setting value for paper out signal (input) [Format] ~H(CNA,P [Parameter] None [Function] This acquires the mode setting value for the paper out signal. Return value after executing this command Description D/0 Mode in which the paper out signal (pin 25) is OFF (not output) 1 Mode in which the paper out signal (pin 25) is as follows: Normal: High, When there is no paper: Low E/2 Mode in which the paper out signal (pin 25) is as follows: Normal: Low, When there is no paper: High Acquisition commands for mode setting values for pause signal (input) [Format] ~H(CNI,P [Parameter] None [Function] Acquire the mode setting values for the pause signal. Return value after executing this command Description 0 Pause signal (pin 12) ignored 1 Pause signal (pin 12) set to switch to the pause state when a Low signal is input for 20 msec or longer 42