Disadvantage, Table D-1, Summary of RAID Methods
UPC - 720591292225
View all HP 166207-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 115 highlights
Drive Arrays and Fault Tolerance Disadvantage The only significant disadvantage of RAID ADG is a relatively low write performance (lower than RAID 5), due to the need for two sets of parity data. Table D-1 summarizes the important features of the different kinds of RAID methods described here. The decision chart in Table D-2 may help you to determine which option is best for your situation. Table D-1: Summary of RAID Methods RAID 0 RAID 1+0 RAID 5 RAID ADG Alternative name Striping (no Mirroring fault tolerance) Distributed Advanced Data Data Guarding Guarding Usable drive space* 100% 50% 67% to 93% 50% to 96% Usable drive space n n/2 (n-1)/n (n-2)/n formula Minimum number of 1 2 physical drives 3 4 Tolerates failure of No Yes one physical drive? Yes Yes Tolerates No Only if no two No Yes simultaneous failure failed drives are of more than one in a mirrored pair physical drive? Read performance High High High High Write performance High Medium Low Low Relative cost Low High Medium Medium *Values for usable drive space are calculated with these assumptions: (1) All physical drives in the array have the same capacity; (2) Online spares are not used; (3) No more than 14 physical drives are used per array for RAID 5; (4) No more than 56 drives are used with RAID ADG. D-10 Compaq Smart Array 5300 Controller User Guide