HP 166207-B21 Smart Array 5300 Controller User Guide - Page 136

When the ProLiant Storage System power, Data Recovery process.

Page 136 highlights

POST Error Messages Table G-1: POST Error Messages continued Message Description 1776 Slot x drive array - SCSI bus termination error - internal and external drives cannot both be attached to the same SCSI port. SCSI port (y): Check cables. 1777 1778 Slot x drive array - ProLiant drive storage enclosure problem detected (followed by one or more of the following): • SCSI port (y): Cooling fan malfunction detected • SCSI port (y): Overheated condition detected • SCSI port (y): Side-panel must be closed to prevent overheating • SCSI port (y): Redundant power supply malfunction detected • SCSI port (y): Wide SCSI transfer failed • SCSI port (y): Interrupt signal inoperative • Check SCSI cables. Slot x drive array resuming Automatic Data Recovery process. Meaning and Recommended Action The internal and external connectors of the specified SCSI port(s) are both attached to drives. The SCSI bus is not properly terminated when internal and external drives are attached concurrently to the same SCSI bus. The indicated SCSI bus is disabled until this problem is resolved. Turn off the server power and check the cabling to the specified SCSI port. Check the cooling fan operation by placing your hand over the fan. Check the internal plenum cooling fan in tower servers or storage systems. If the fan is not operating, check for obstructions and check all internal connectors. Replace the unit side panel, if it was removed. When the ProLiant Storage System power LED is amber instead of green, the following conditions may be present: • A fan failure • A redundant power supply failure • A thermal problem If the message directs you to check SCSI cables, check your cabling against the diagrams in this user guide. If the routing is correct, replace cables on the specified port until the POST message is eliminated. No action required. This message appears whenever a controller reset or power cycle occurs while Automatic Data Recovery is in progress. continued G-6 Compaq Smart Array 5300 Controller User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

POST Error Messages
G-6
Compaq Smart Array 5300 Controller User Guide
Table G-1:
POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1776
Slot x drive array
SCSI bus
termination error
internal and
external drives cannot both be
attached to the same SCSI port.
SCSI port (y):
Check cables.
The internal and external connectors of the
specified SCSI port(s) are both attached to
drives. The SCSI bus is not properly
terminated when internal and external
drives are attached concurrently to the
same SCSI bus. The indicated SCSI bus is
disabled until this problem is resolved.
Turn off the server power and check the
cabling to the specified SCSI port.
1777
Slot x drive array
ProLiant drive
storage enclosure problem detected
(followed by one or more of the
following):
SCSI port (y): Cooling fan
malfunction detected
SCSI port (y): Overheated
condition detected
SCSI port (y): Side-panel must be
closed to prevent overheating
SCSI port (y): Redundant power
supply malfunction detected
SCSI port (y): Wide SCSI transfer
failed
SCSI port (y): Interrupt signal
inoperative
Check SCSI cables.
Check the cooling fan operation by placing
your hand over the fan. Check the internal
plenum cooling fan in tower servers or
storage systems. If the fan is not operating,
check for obstructions and check all internal
connectors. Replace the unit side panel, if it
was removed.
When the ProLiant Storage System power
LED is amber instead of green, the
following conditions may be present:
A fan failure
A redundant power supply failure
A thermal problem
If the message directs you to check SCSI
cables, check your cabling against the
diagrams in this user guide. If the routing is
correct, replace cables on the specified port
until the POST message is eliminated.
1778
Slot x drive array resuming Automatic
Data Recovery process.
No action required. This message appears
whenever a controller reset or power cycle
occurs while Automatic Data Recovery is in
progress.
continued