HP 166207-B21 Smart Array 5300 Controller User Guide - Page 119

Table E-1, Hard Drive Status from LED Illumination Pattern, Hard Drive Installation and Replacement

Page 119 highlights

Hard Drive Installation and Replacement Table E-1: Hard Drive Status from LED Illumination Pattern (1) Activity On, off, or flashing On, off, or flashing On On Flashing Off Off (2) Online On or off On Flashing Off Flashing Off Off (3) Fault Flashing Off Off Off Flashing On Off Meaning A predictive failure alert has been received for this drive. Replace the drive as soon as possible. OK to replace the drive online if the array is configured for fault tolerance and all other drives in the array are online. The drive is online and configured as part of an array. Do not remove the drive. Removing a drive during this process may terminate the current operation and cause data loss. The drive is rebuilding or undergoing capacity expansion. Do not remove the drive. Removing a drive during this process may cause data loss. The drive is being accessed, but (1) it is not configured as part of an array; (2) it is a replacement drive and rebuild has not yet started; or (3) it is spinning up during POST. Do not remove the drive. Removing a drive during this process can cause data loss in non-fault-tolerant configurations. Either (1) the drive is part of an array being selected by the Array Configuration Utility; (2) the Options ROMPaq utility is upgrading the drive firmware; or (3) Drive Identification has been selected in Compaq Insight Manager. OK to replace the drive online. The drive has failed and has been placed offline. OK to replace the drive online if the array is configured for fault tolerance and all other drives in the array are online. Either (1) the drive is not configured as part of an array; (2) the drive is configured as part of an array, but a powered-up controller is not accessing the drive; or (3) the drive is configured as an online spare. Compaq Smart Array 5300 Controller User Guide E-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

Hard Drive Installation and Replacement
Compaq Smart Array 5300 Controller User Guide
E-3
Table E-1:
Hard Drive Status from LED Illumination Pattern
(1) Activity
(2) Online
(3) Fault
Meaning
On, off, or
flashing
On or off
Flashing
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
On, off, or
flashing
On
Off
OK to replace the drive online if the array is configured
for fault tolerance and all other drives in the array are
online.
The drive is online and configured as part of an array.
On
Flashing
Off
Do not remove the drive. Removing a drive during
this process may terminate the current operation and
cause data loss.
The drive is rebuilding or undergoing capacity expansion.
On
Off
Off
Do not remove the drive. Removing a drive during
this process may cause data loss.
The drive is being accessed, but (1) it is not configured
as part of an array; (2) it is a replacement drive and
rebuild has not yet started; or (3) it is spinning up during
POST.
Flashing
Flashing
Flashing
Do not remove the drive. Removing a drive during
this process can cause data loss in non-fault-tolerant
configurations.
Either (1) the drive is part of an array being selected by
the Array Configuration Utility; (2) the Options ROMPaq
utility is upgrading the drive firmware; or (3) Drive
Identification has been selected in Compaq Insight
Manager.
Off
Off
On
OK to replace the drive online.
The drive has failed and has been placed offline.
Off
Off
Off
OK to replace the drive online if the array is configured
for fault tolerance and all other drives in the array are
online.
Either (1) the drive is not configured as part of an array;
(2) the drive is configured as part of an array, but a
powered-up controller is not accessing the drive; or
(3) the drive is configured as an online spare.