HP 166207-B21 Smart Array 5300 Controller User Guide - Page 137
Port y: SCSI ID x, Check that the controller is firmly inserted
UPC - 720591292225
View all HP 166207-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
POST Error Messages Table G-1: POST Error Messages continued Message Description 1779 Slot x drive array - replacement drive(s) detected or previously failed drive(s) now appear to be operational: Port (y): SCSI ID (x) Restore data from backup if replacement drive x has been installed. 1783 Slot x drive array controller failure. 1784 Slot x drive array drive failure. The following SCSI drive(s) should be replaced: SCSI port (y) SCSI ID (x) Meaning and Recommended Action If this message appears and drive x has not been replaced, an intermittent drive failure has occurred. This message also appears once immediately following drive replacement before data is restored from backup. If this message appears immediately following a ROM installation, the ROM is either defective or not installed properly. Check that the controller is firmly inserted in its slot. Check for improper cabling or SCSI ID conflicts. Try upgrading the system ROM. Otherwise, replace the array controller. Check for loose cables. Replace defective drive x and/or cable(s). continued Compaq Smart Array 5300 Controller User Guide G-7