HP 166207-B21 Smart Array 5300 Controller User Guide - Page 134

POST Error Messages, Compaq Smart Array 5300 Controller User Guide, Run System ROMPaq Utility.

Page 134 highlights

POST Error Messages Table G-1: POST Error Messages continued Message Description 1758 Slot x drive array - array accelerator size mismatch between controllers. 64MB array accelerator should be attached to both controllers. 1759 1762 1763 1764 Slot x drive array - redundant controller error Redundant controller operation is not supported in this firmware version. Please remove redundant controller or upgrade controller firmware. (Controller is disabled until this problem is resolved.) Array accelerator daughtercard is detached; please reattach. (Controller is disabled until this problem is resolved.) Slot x drive array - capacity expansion process is temporarily disabled (followed by a cause). 1765 1766 Slot x drive array Option ROM appears to conflict with an ISA card - ISA cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF along with SMART-2/E 8-bit Option ROM due to EISA buffer limitations. Please remove or reconfigure your ISA card. Slot x drive array requires System ROM upgrade. Run System ROMPaq Utility. Meaning and Recommended Action The size of the array accelerators is different between two controllers in a redundant controller configuration. Use array accelerators of the same size on both controllers. Replace controller or server system board. Remove the redundant controller or visit the Compaq website and get the latest upgrade for the controller firmware. This controller model cannot operate if the array accelerator is detached. Reattach the array accelerator. The capacity expansion process has been temporarily disabled for the reason indicated and will automatically resume. If the array accelerator has been removed, you must reinstall it for capacity expansion to continue. Remove or reconfigure the conflicting ISA card, referring to the directions provided with the ISA card. Alternatively, the Option ROM can be disabled on the SMART-2/E controller through the System Configuration Utility if a SMART-2/E is not the primary (boot) controller. Run the latest version of the System ROMPaq utility. continued G-4 Compaq Smart Array 5300 Controller User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

POST Error Messages
G-4
Compaq Smart Array 5300 Controller User Guide
Table G-1:
POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1758
Slot x drive array
array accelerator
size mismatch between controllers.
64MB array accelerator should be
attached to both controllers.
The size of the array accelerators is
different between two controllers in a
redundant controller configuration. Use
array accelerators of the same size on both
controllers.
1759
Slot x drive array
redundant
controller error
Replace controller or server system board.
1762
Redundant controller operation is not
supported in this firmware version.
Please remove redundant controller or
upgrade controller firmware. (Controller
is disabled until this problem is
resolved.)
Remove the redundant controller or visit the
Compaq website and get the latest upgrade
for the controller firmware.
1763
Array accelerator daughtercard is
detached; please reattach. (Controller
is disabled until this problem is
resolved.)
This controller model cannot operate if the
array accelerator is detached. Reattach the
array accelerator.
1764
Slot x drive array
capacity expansion
process is temporarily disabled
(followed by a cause).
The capacity expansion process has been
temporarily disabled for the reason
indicated and will automatically resume. If
the array accelerator has been removed,
you must reinstall it for capacity expansion
to continue.
1765
Slot x drive array Option ROM appears
to conflict with an ISA card
ISA cards
with 16-bit memory cannot be
configured in memory range C0000 to
DFFFF along with SMART-2/E 8-bit
Option ROM due to EISA buffer
limitations. Please remove or
reconfigure your ISA card.
Remove or reconfigure the conflicting ISA
card, referring to the directions provided
with the ISA card. Alternatively, the Option
ROM can be disabled on the SMART-2/E
controller through the System Configuration
Utility if a SMART-2/E is not the primary
(boot) controller.
1766
Slot x drive array requires System
ROM upgrade.
Run System ROMPaq Utility.
Run the latest version of the System
ROMPaq utility.
continued