Enter, Caution, reprogramming is complete.

Page 38 highlights

Updating the Controller Firmware 5. If the controller that you want to update the firmware for is on the list of programmable devices, select it and press the Enter key. (If it is not present, you are prompted to insert the remaining diskettes for devices not listed on the first diskette.) 6. The action that you must now take depends on the message on the screen. - If the screen message reads as follows, press the Enter key, and then go to step 8 of these instructions: The ROM image files found for the device selected are not newer than the current ROM image - If the ROM firmware currently on the controller is older than that on the Options ROMPaq diskette, then the screen message reads as follows: Device to reprogram: All Compaq Smart Array nnnn Controller(s) Controller(s) Current ROM revision: Compaq Smart Array nnnn Controller x.xx Select Firmware Images: Compaq Smart Array nnnn Controller y.yy In this case, press the Enter key and then go to step 7. 7. Review the information on the Caution screen, and then press the Enter key to reprogram the controller ROM. The following message is displayed: Reprogramming Firmware Do not interrupt the reprogramming process. You will be notified when reprogramming is complete. 8. When the reprogramming of the array controller ROM is finished, you can reprogram more options or exit the utility. - To reprogram another Compaq option, press the Enter key, and then repeat steps 5 through 7. - If you have finished reprogramming Compaq options, press the Esc key to exit the utility. 9. Remove the Options ROMPaq diskette and restart the server. Compaq Smart Array 5300 Controller User Guide 5-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

Updating the Controller Firmware
Compaq Smart Array 5300 Controller User Guide
5-5
5.
If the controller that you want to update the firmware for is on the list of
programmable devices, select it and press the
Enter
key. (If it is not present, you
are prompted to insert the remaining diskettes for devices not listed on the first
diskette.)
6.
The action that you must now take depends on the message on the screen.
If the screen message reads as follows, press the
Enter
key, and then go to
step 8 of these instructions:
The ROM image files found for the device selected are not
newer than the current ROM image
If the ROM firmware currently on the controller is older than that on the
Options ROMPaq diskette, then the screen message reads as follows:
Device to reprogram:
All Compaq Smart Array
nnnn
Controller(s)
Controller(s) Current ROM revision: Compaq Smart Array
nnnn
Controller
x.xx
Select Firmware Images: Compaq Smart Array
nnnn
Controller
y.yy
In this case, press the
Enter
key and then go to step 7.
7.
Review the information on the
Caution
screen, and then press the
Enter
key to
reprogram the controller ROM.
The following message is displayed:
Reprogramming Firmware
Do not interrupt the reprogramming process. You will be notified when
reprogramming is complete.
8.
When the reprogramming of the array controller ROM is finished, you can
reprogram more options or exit the utility.
To reprogram another Compaq option, press the
Enter
key, and then repeat
steps 5 through 7.
If you have finished reprogramming Compaq options, press the
Esc
key to
exit the utility.
9.
Remove the Options ROMPaq diskette and restart the server.