HP 2500 HP Jetdirect Print Servers - Administrator Guide - Page 231

Table 9.11, Token Ring Diagnostic Information 2 of 2, HP Jetdirect Configuration

Page 231 highlights

Table 9.11 Token Ring Diagnostic Information (2 of 2) Message Ring Status: Description Request Param: The HP Jetdirect print server determines that a Ring Parameter Server (RPS) is present on the ring, but does not respond to a request initialization data frame. Remove Received: The HP Jetdirect print server has received a Remove Adapter data frame during the Token Ring insertion process, or has received a remove ring station data frame request, and has removed itself from the ring. The following Ring Status may be detected: Ring Recovery: The HP Jetdirect print server has received claim-token data frames on the ring. The HP Jetdirect print server may be transmitting the claim-token frames. Single Station: The HP Jetdirect print server has sensed that it is the only station on the ring. Remove Received: The HP Jetdirect print server has received a Remove Adapter data frame during the Token Ring insertion process, or has received a remove ring station data frame request, and has removed itself from the ring. Auto-Removal Error: The HP Jetdirect print server detected an internal hardware error following the Token Ring beacon auto-removal process and has removed itself from the ring. Lobe Wire Fault: The HP Jetdirect print server has detected an open or short circuit in the cable between the HP Jetdirect print server and the Token Ring wiring concentrator. Verify that this cable is functional and replace it if necessary. Transmit Beacon: The HP Jetdirect print server is transmitting beacon frames to the ring. Hard Error: The HP Jetdirect print server is transmitting or receiving beacon frames to or from the ring. Signal Loss: Indicates one of the following: G The HP Jetdirect print server has detected a loss of signal on the ring. Check the cable from the HP Jetdirect print server to the network and check the wiring concentrator. G A signal loss condition has been detected at the HP Jetdirect print server receiver input during the open process (either when wrapped or inserted onto the ring). ENWW HP Jetdirect Configuration Page 231

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302

ENWW
HP Jetdirect Configuration Page 231
Request Param: The HP Jetdirect print server determines
that a Ring Parameter Server (RPS) is present on the ring,
but does not respond to a request initialization data frame.
Remove Received: The HP Jetdirect print server has
received a Remove Adapter data frame during the Token
Ring insertion process, or has received a remove ring
station data frame request, and has removed itself from the
ring.
Ring Status:
The following Ring Status may be detected:
Ring Recovery: The HP Jetdirect print server has received
claim-token data frames on the ring. The HP Jetdirect print
server may be transmitting the claim-token frames.
Single Station: The HP Jetdirect print server has sensed
that it is the only station on the ring.
Remove Received: The HP Jetdirect print server has
received a Remove Adapter data frame during the Token
Ring insertion process, or has received a remove ring
station data frame request, and has removed itself from the
ring.
Auto-Removal Error: The HP
Jetdirect print server detected
an internal hardware error following the Token Ring beacon
auto-removal process and has removed itself from the ring.
Lobe Wire Fault: The HP
Jetdirect print server has detected
an open or short circuit in the cable between the
HP Jetdirect print server and the Token Ring wiring
concentrator. Verify that this cable is functional and replace
it if necessary.
Transmit Beacon: The HP Jetdirect print server is
transmitting beacon frames to the ring.
Hard Error: The HP Jetdirect print server is transmitting or
receiving beacon frames to or from the ring.
Signal Loss: Indicates one of the following:
The HP Jetdirect print server has detected a loss
of signal on the ring. Check the cable from the
HP Jetdirect print server to the network and check the
wiring concentrator.
A signal loss condition has been detected at the
HP Jetdirect print server receiver input during the open
process (either when wrapped or inserted onto the ring).
Table 9.11
Token Ring Diagnostic Information (2 of 2)
Message
Description