HP 3PAR StoreServ 7450 2-node HP 3PAR StoreServ 7450 Storage Troubleshooting G - Page 34

Cage Example 3, Cage Suggested Action 3

Page 34 highlights

VendorId,ProductId 3PARdata,DC2 Unique_ID 10320300000AD000 Power Supply Info State Fan State AC Model ps0 Failed OK Failed POI

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

VendorId,ProductId
3PARdata,DC2
Unique_ID 10320300000AD000
Power Supply Info
State Fan State
AC Model
ps0 Failed
OK Failed
POI <AC input is missing
ps1
OK
OK
OK
POI
ps2
Off
OK
OK
POI <PS switch is turned off
ps3
OK
OK
OK
POI
Cage Example 3
Component -Identifier- --------------Description----------------
Cage
cage:1
Cage has a hotplug enabled interface card
Cage Suggested Action 3
When a
servicecage
operation is started, it puts the targeted cage into servicing mode and
illuminates the hot plug LED on the FCAL module (DC1, DC2, DC4), and causes I/O to be routed
through the other path. When the service action is finished, the
servicecage endfc
command
should be issued to return the cage to normal status. This
checkhealth
exception is reported if
the FCAL module's hot plug LED is illuminated or if the cage is in servicing mode. If a maintenance
activity is currently occurring on the drive cage, this condition may be ignored.
NOTE:
The primary path can be seen by an asterisk (*) in
showpd's Ports
columns.
cli% showcage -d cage1
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
RevA RevB Model Side
1 cage1 0:0:2
0 1:0:2
0
24 28-40 2.37 2.37 DC2
n/a
-----------Cage detail info for cage1 ---------
Interface Board Info
FCAL0
FCAL1
Link A RXLEDs
Green
Off
Link A TXLEDs
Green
Off
Link B RXLEDs
Off
Green
Link B TXLEDs
Off
Green
LED(Loop_Split)
Off
Off
LEDS(system,hotplug) Green,Off Green,Amber
-----------Midplane Info-----------
Firmware_status
Current
Product_Rev
2.37
State
Normal Op
Loop_Split
0
VendorId,ProductId
3PARdata,DC2
Unique_ID 10320300000AD000
cli% showpd -s
Id CagePos Type -State-- -----Detailed_State------
20 1:0:0
FC
degraded disabled_B_port,servicing
21 1:0:1
FC
degraded disabled_B_port,servicing
22 1:0:2
FC
degraded disabled_B_port,servicing
23 1:0:3
FC
degraded disabled_B_port,servicing
cli% showpd -p -cg 1
---Size(MB)---- ----Ports----
Id CagePos Type Speed(K) State
Total
Free A
B
20 1:0:0
FC
10 degraded
139520
119808 0:0:2* 1:0:2-
21 1:0:1
FC
10 degraded
139520
122112 0:0:2* 1:0:2-
22 1:0:2
FC
10 degraded
139520
119552 0:0:2* 1:0:2-
23 1:0:3
FC
10 degraded
139520
122368 0:0:2* 1:0:2-
34
Troubleshooting