HP 3PAR StoreServ 7450 2-node HP 3PAR StoreServ 7450 Storage Troubleshooting G - Page 43
Node Suggested Action 1, Node Example 2, and the like. Turn on or replace the failed power supply.
View all HP 3PAR StoreServ 7450 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Node Node node:1 node:1 Power supply 0 AC state is Failed Power supply 0 DC state is Failed Node Suggested Action 1 Examine the states of the power supplies with commands such as shownode, shownode -s, shownode -ps, and the like. Turn on or replace the failed power supply. NOTE: In the example below, the battery state is considered Degraded because the power supply is Failed; this is normal. cli% shownode Control Data Cache Node --Name--- -State-- Master InCluster ---LED--- Mem(MB) Mem(MB) Available(%) 0 1001356-0 Degraded Yes Yes AmberBlnk 2048 8192 100 1 1001356-1 Degraded No Yes AmberBlnk 2048 8192 100 cli% shownode -s Node -State-- -Detailed_State- 0 Degraded PS 1 Failed 1 Degraded PS 0 Failed cli% shownode -ps Node PS -Serial- -PSState- FanState ACState DCState -BatState- ChrgLvl(%) 0 0 FFFFFFFF OK OK OK OK OK 100 0 1 FFFFFFFF Failed -- OK Failed Degraded 100 1 0 FFFFFFFF Failed -- Failed Failed Degraded 100 1 1 FFFFFFFF OK OK OK OK OK 100 Node Example 2 Component -Identifier- ---------Description------------ Node node:3 Power supply 1 battery is Failed Node Suggested Action 2 Examine the state of the battery and power supplies with commands such as shownode, shownode -s, shownode -ps, showbattery (and showbattery with -d, -s, -log), and the like. Turn on, fix, or replace the battery backup unit. NOTE: The condition of the Degraded Power Supply (PS) is due to the battery failing. cli% shownode Control Data Cache Node --Name--- -State-- Master InCluster ---LED--- Mem(MB) Mem(MB) Available(%) 2 1001356-2 OK No Yes GreenBlnk 2048 8192 100 3 1001356-3 Degraded No Yes AmberBlnk 2048 8192 100 cli% shownode -s Node -State-- -Detailed_State- 2 OK OK 3 Degraded PS 1 Degraded cli% shownode -ps Node PS -Serial- -PSState- FanState ACState DCState -BatState- ChrgLvl(%) 2 0 FFFFFFFF OK OK OK OK OK 100 2 1 FFFFFFFF OK OK OK OK OK 100 3 0 FFFFFFFF OK OK OK OK OK 100 3 1 FFFFFFFF Degraded OK OK OK Failed 0 Troubleshooting Storage System Components 43