Figure 4 HP 3PAR StoreServ Four-node Configuration Storage Numbering PCIe Slots and Ports This table lists the default port configurations for the HP 3PAR StoreServ 7450 Storage systems. Table 1 Storage System Expansion Cards Expansion cards 2 FC HBAs only 2 10 Gb/s converged network adapter (CNA) only 2 FC HBAs + 2 10 Gb/s CNAs Nodes 0 and 1 1 FC HBA each 1 10 Gb/s CNA each 1 FC HBA each Nodes 2 and 3 No expansion card No expansion card 1 10 Gb/s CNA each You can have either a 10 GB CNA or an FC card in the expansion slots of all nodes, or a mix in case of a four-node system (two 10 Gb CNA and 2 FC). Each node enclosure must have matching PCIe cards. NOTE: If you are upgrading from a two-node to a four-node configuration, you can have CNAs installed in node 0 and node 1, and FC HBAs installed in node 2 and node 3. Figure 5 Location of Controller Node Ports Table 2 Controller Node Ports Item Port 1 2 Ethernet MGMT--Used to connect to the storage array management interfaces RC--Used to connect to Remote Copy 2 Fibre Channel (FC-1 and FC-2)--used to connect to host systems 8 Identifying Storage System Components

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

Figure 4 HP 3PAR StoreServ Four-node Configuration Storage Numbering
PCIe Slots and Ports
This table lists the default port configurations for the HP 3PAR StoreServ 7450 Storage systems.
Table 1 Storage System Expansion Cards
Nodes 2 and 3
Nodes 0 and 1
Expansion cards
No expansion card
1 FC HBA each
2 FC HBAs only
No expansion card
1 10 Gb/s CNA each
2 10 Gb/s converged network
adapter (CNA) only
1 10 Gb/s CNA each
1 FC HBA each
2 FC HBAs + 2 10 Gb/s CNAs
You can have either a 10 GB CNA or an FC card in the expansion slots of all nodes, or a mix in
case of a four-node system (two 10 Gb CNA and 2 FC).
Each node enclosure must have matching PCIe cards.
NOTE:
If you are upgrading from a two-node to a four-node configuration, you can have CNAs
installed in node 0 and node 1, and FC HBAs installed in node 2 and node 3.
Figure 5 Location of Controller Node Ports
Table 2 Controller Node Ports
Port
Item
2 Ethernet
MGMT--Used to connect to the storage array management interfaces
1
RC--Used to connect to Remote Copy
Fibre Channel (FC-1 and FC-2)--used to connect to host systems
2
8
Identifying Storage System Components