HP 3PAR StoreServ 7450 2-node HP 3PAR StoreServ 7450 Storage Troubleshooting G - Page 44
Node Example 3, Node Suggested Action 3, PD, Checks for an imbalance of PD ports, for example
View all HP 3PAR StoreServ 7450 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
cli% showbattery Node PS Bat Serial -State-- ChrgLvl(%) -ExpDate-- Expired Testing 3 0 0 100A300B OK 100 07/01/2011 No No 3 1 0 12345310 Failed 0 04/07/2011 No No Node Example 3 Component -Identifier Description Node node:3 Node:3, Power Supply:1, Battery:0 has not been tested within the last 30 days Node Suggested Action 3 The indicated battery has not been tested in the past 30 days. A node backup battery is tested every 14 days under normal conditions, but if a battery is missing, expired, or failed, it is not tested. In addition, the other battery connected to the same node is not tested because testing it would cause loss of battery backup to the node, and the system does not allow that. An untested battery has an Unknown status in the showbattery -s output. Use commands such as showbattery, showbattery -s, and showbattery -d. showbattery -s Node PS Bat -State-- -Detailed_State- 0 0 0 OK normal 0 1 0 Degraded Unknown Examine the date of the last successful test of that battery. Assuming the comment date was 2009-10-14, the last battery test on Node 0, PS 1, Bat 0 was 2009-09-10, which is more than 30 days ago. showbattery -log Node PS Bat Test Result Dur(mins) ---------Time---------- 0 0 0 0 Passed 1 2009-10-14 14:34:50 PDT 0 0 0 1 Passed 1 2009-10-28 14:36:57 PDT 0 1 0 0 Passed 1 2009-08-27 06:17:44 PDT 0 1 0 1 Passed 1 2009-09-10 06:19:34 PDT showbattery Node PS Bat Serial -State-- ChrgLvl(%) -ExpDate-- Expired Testing 0 0 0 83205243 OK 100 04/07/2011 No No 0 1 0 83202356 Degraded 100 04/07/2011 No No PD Displays Physical Disks (PDs) with states or conditions that are not optimal: • Checks for failed and degraded PDs • Checks for an imbalance of PD ports, for example, if Port-A is used on more disks than Port-B • Checks for an Unknown Sparing Algorithm. For example, when it hasn't been set • Checks for disks experiencing a high number of IOPS • Reports if a servicemag operation is outstanding (servicemag status) • Reports if there are PDs that do not have entries in the firmware DB file 44 Troubleshooting