HP 6100 HP 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software G - Page 46
Code Load System, Second code load confirmation screen
View all HP 6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Figure 14 First code load confirmation screen Figure 15 Second code load confirmation screen 8. Click Code Load System. The new storage system software is copied to the controllers and validated. A sliding bar progress screen is updated as the code segments are validated. 9. The upgrade process begins and the Initializing firmware code load page opens. See Figure 16 (page 46). This page is displayed while the upgrade components are processed. Figure 16 Initializing firmware code load After Figure 16 (page 46) appears, both controllers resynchronize and begin operating with the new controller software version. Once the resynchronization is complete, the controllers being processing host I/Os. Next additional code within the storage system is updated, which can take up to 10 minutes to complete. This includes firmware on the I/O modules in the disk enclosures. During this interval, the Storage System Updating Firmware window opens (Figure 17 (page 46)). Figure 17 Storage system updating firmware 46 Upgrading the Enterprise Virtual Array