HP 6400/8400 HP StorageWorks Enterprise Virtual Array Updating Product Softwar - Page 60
I/O tab of Disk Enclosure Properties window, The Disk Enclosure Properties window opens.
View all HP 6400/8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
12. After 30 minutes, verify the I/O module firmware version and states on each I/O module of each disk enclosure as follows: a. In HP Command View EVA, go to the Hardware folder in the navigation pane and select a disk enclosure. The Disk Enclosure Properties window opens. b. Select the I/O tab. c. Record the firmware version and operational state of each I/O module (both I/O module A and B). Also, record any I/O modules that have blank fields (see Figure 23 for an example). d. Verify that 0085 displays in the Firmware revision field (for both I/O module A and B) and verify that the Operational state (for both I/O modules A and B) displays Good (see Figure 22) for every I/O module. If so, the upgrade was successful. Figure 22 I/O tab of Disk Enclosure Properties window . If there are blank fields on the I/O tab of the Disk Enclosure Properties window (see Figure 23 for an example), you can optionally choose to reset the I/O module to clear the blank fields after the I/O module firmware upgrade has completed successfully, although blank fields do not affect the array's ability to process host I/O. See "Resetting the I/O module" on page 62 for more information. 60 Upgrading the Enterprise Virtual Array