HP 6400/8400 HP StorageWorks Enterprise Virtual Array Updating Product Softwar - Page 70

Step 8. Resuming storage system operation, Step 1. Checking the health of

Page 70 highlights

Step 8. Resuming storage system operation Estimated time to complete: Varies. After the storage system software and disk firmware have been successfully upgraded, the storage system can be returned to normal operation. 1. Using HP Command View EVA, check the overall status of the storage system to ensure there are no problems. For instructions on checking the status, see "Step 1. Checking the health of the Enterprise Virtual Array" on page 49. 2. If you did on offline upgrade, perform the following steps: a. Restart any host servers that were shutdown for the upgrade. b. Resume host I/Os. 3. When running HP Continuous Access EVA, set the Failsafe on unavailable member mode to Enabled on all DR groups if it was disabled before the upgrade. See "Preparing an HP Continuous Access EVA environment for upgrading" on page 44. 4. If you changed any host LUN timeout values, reset them to their original values. 5. If you are running Remote Support Software, enable it as follows: a. Save and clean the application eventlog file. b. On the HP Command View EVA management server, open a command window. c. Enter the following commands to restart Remote Support Software: C:\>net start desta_service d. Enter exit. 6. Update the MIB file after the upgrade to ensure SNMP notifications are captured correctly. See "Retrieving the Management Information Base" in the HP StorageWorks Command View EVA User Guide for detailed instructions. 70 Upgrading the Enterprise Virtual Array

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Step 8. Resuming storage system operation
Estimated time to complete:
Varies.
After the storage system software and disk firmware have been successfully upgraded, the storage
system can be returned to normal operation.
1.
Using HP Command View EVA, check the overall status of the storage system to ensure there are
no problems. For instructions on checking the status, see
Step 1. Checking the health of the
Enterprise Virtual Array
on page 49.
2.
If you did on offline upgrade, perform the following steps:
a.
Restart any host servers that were shutdown for the upgrade.
b.
Resume host I/Os.
3.
When running HP Continuous Access EVA, set the Failsafe on unavailable member mode to
Enabled on all DR groups if it was disabled before the upgrade. See
Preparing an HP Continuous
Access EVA environment for upgrading
on page 44.
4.
If you changed any host LUN timeout values, reset them to their original values.
5.
If you are running Remote Support Software, enable it as follows:
a.
Save and clean the application eventlog file.
b.
On the HP Command View EVA management server, open a command window.
c.
Enter the following commands to restart Remote Support Software:
C:\>net start desta_service
d.
Enter
exit
.
6.
Update the MIB file after the upgrade to ensure SNMP notifications are captured correctly. See
Retrieving the Management Information Base
in the
HP StorageWorks Command View EVA
User Guide
for detailed instructions.
Upgrading the Enterprise Virtual Array
70