HP 6400/8400 HP StorageWorks Enterprise Virtual Array Updating Product Softwar - Page 81

Solving problems with multiple resynchronizations, Run HP Command View EVA and log in.

Page 81 highlights

• Check any WEBES messages. 1. Double click on the System Event Analyzer icon on the management server to run WEBES. 2. Click Full View under either System Log or the appropriate storage system in the left navigation pane. • Check the storage system event logs. 1. Run HP Command View EVA and log in. 2. Select the storage system whose logs you want to view. 3. Click View events to view the event logs that can be displayed. If none of the above recommendations resolves the problem, contact your HP-authorized service representative for help. Solving problems with multiple resynchronizations During the upgrade process, both controllers perform a resynchronization simultaneously. This invokes a fast restart of the controllers - bypassing execution of lengthy hardware diagnostics. This fast restart allows the controllers to complete the resynchronization sequence before the host timeout period elapses and the host becomes aware that the storage system is unavailable. If an event occurs that causes a second resynchronization while the upgrade resynchronization is still in progress, the controller will terminate with a code of 0b 08 01 00. The following events cause the controller to resysnchronize automatically: • Initialization of the storage system • Setting debug flags through the command line interface or WOCP • Disk group hardware problem on a Vraid1 virtual disk, or attempted re-connection of a disk when there is a disk group hardware problem • Bad Block Replacement (BBR) performed on a disk • Memory allocation failure or other errors Every effort should be made to ensure that none of these events occur during the upgrade process. If controller termination occurs due to multiple resynchronizations, contact your HP-authorized service representative for assistance. HP StorageWorks Enterprise Virtual Array Updating Product Software Guide (XCS 09534000) 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Check any WEBES messages.
1.
Double click on the System Event Analyzer icon on the management server to run WEBES.
2.
Click
Full View
under either System Log or the appropriate storage system in the left navigation
pane.
Check the storage system event logs.
1.
Run HP Command View EVA and log in.
2.
Select the storage system whose logs you want to view.
3.
Click
View events
to view the event logs that can be displayed.
If none of the above recommendations resolves the problem, contact your HP-authorized service
representative for help.
Solving problems with multiple resynchronizations
During the upgrade process, both controllers perform a resynchronization simultaneously. This invokes
a fast restart of the controllers
bypassing execution of lengthy hardware diagnostics. This fast restart
allows the controllers to complete the resynchronization sequence before the host timeout period
elapses and the host becomes aware that the storage system is unavailable.
If an event occurs that causes a second resynchronization while the upgrade resynchronization is still
in progress, the controller will terminate with a code of
0b 08 01 00
. The following events cause
the controller to resysnchronize automatically:
Initialization of the storage system
Setting debug flags through the command line interface or WOCP
Disk group hardware problem on a Vraid1 virtual disk, or attempted re-connection of a disk when
there is a disk group hardware problem
Bad Block Replacement (BBR) performed on a disk
Memory allocation failure or other errors
Every effort should be made to ensure that none of these events occur during the upgrade process. If
controller termination occurs due to multiple resynchronizations, contact your HP-authorized service
representative for assistance.
HP StorageWorks Enterprise Virtual Array Updating Product Software Guide (XCS 09534000)