HP 6400/8400 HP StorageWorks Enterprise Virtual Array Updating Product Softwar - Page 75
Unknown storage system, Symptom, Cause of the error, Corrective Action, Possible Cause, Unknown
View all HP 6400/8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 75 highlights
Possible Cause Corrective Action 404 Error: A .frm (HTML) file may be missing in the HP Command View EVA directory structure. This can occur if the files were changed or if HP Command View EVA was not successfully installed. Reinstall HP Command View EVA. 503 Error: HP Command View EVA may be down when a browser makes a request. The web server returns a 503 (No Service) error because it cannot access the page. Retry the request when HP Command View EVA is up. Browser timeout: The appliance may be down or the web server may be unavailable when a browser makes a request to HP Command View EVA. In this case, the browser will time out internally. Retry the request when the appliance and HP Command View EVA are up. Unknown storage system Symptom HP Command View EVA reports an unknown storage system for a storage system that should be displayed. Cause of the error HP Command View EVA may have lost communication with the controllers. Two possible scenarios are: • The HBA in the management server may have timed out commands to the controllers. See "Unknown storage system-cause 1" on page 75 below. • The controllers are running a version of XCS that HP Command View EVA does not recognize. See "Unknown storage system-cause 2" on page 75. Unknown storage system-cause 1 When the array is heavily loaded, the FC adapter in the management server may time out commands to the controllers. If this occurs, the storage system appears in the Unknown state. Corrective Action for Unknown Storage System-Cause 1 This scenario should correct itself in less than one minute. Alternately, you can perform a Rediscover operation to initiate new commands to the controller. Unknown storage system-cause 2 HP Command View EVA can only manage controllers that are running supported XCS versions. Corrective Action for Unknown Storage System-Cause 2 Ensure that you are running the HP Command View EVA version that is compatible with XCS 09534000. See the "HP Command View EVA interoperability support" table in the HP StorageWorks Enterprise Virtual Array Compatibility Reference to determine which version of HP Command View EVA you should be running. Then, upgrade HP Command View EVA to a compatible version. See "Required documentation" on page 10 for the link to this document. HP StorageWorks Enterprise Virtual Array Updating Product Software Guide (XCS 09534000) 75