HP 8/80 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
HP 8/80 Manual
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 8/80 manual content summary:
- HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 1
53-1001767-01 ® 30 March 2010 Fabric OS Message Reference Supporting Fabric OS v6.4.0 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 2
Networks set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service the computer support Error Message Reference v3.1.0 Diagnostic and System Error Message Reference v4.1.0 Diagnostic and System Error Message Reference v4.1.2 Diagnostic and System Error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 3
Publication Summary of changes Date number Diagnostic and System Error Message Reference v4.2.0 53-0000515-08 Update software and hardware support March 2004 Fabric OS System Error Message 53-0000515-09 Updated for v4.4.0, Reference Manual First RASLog release August 2004 Fabric OS System - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 4
Introductory chapters. November 2008 53-1001338-01 Updated for Fabric OS v6.3.0: -Modified a message to BKSW, BL, BKSW, BLL, CDR, CEE CONFIG, CONF, EM, FCOE, FCPD, FCPH, FCR, FICON, FICU, FLOD, FSPF, FSSM, FW, HAM, ,HAMK, HIL, IPS, ISNS, L2SYS, MFIC, PDM, PLAT, PORT, RCS, RPCD, RTWR, SEC, SNMP - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 5
In this chapter lxix How this document is organized lxix Supported hardware and software lxix What's new in this document Messages 1 System Error Message Logging 1 Event Auditing 2 System Logging Daemon (syslogd 3 System Console 3 Port Logs 3 Viewing and Configuring System Message Logs - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 6
Responding to a System Message 11 Looking Up a System Message 12 Gathering Information About the Problem 12 Support 13 Panic Dump and Core Dump Files 13 Trace Dumps 13 supportSave Command 13 System Module Descriptions 13 Section I RASLog Messages Chapter 2 AG System Messages - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 7
Chapter 3 Chapter 4 AG-1026 32 AG-1027 32 AG-1028 32 AG-1029 32 AG-1030 33 AG-1031 33 AG-1032 33 AG-1033 33 AG-1034 34 AG-1035 34 AG-1036 34 AG-1037 34 AG-1038 35 AG-1039 35 AN System Messages AN-1001 37 AN-1002 37 AN-1003 37 AN-1004 38 AN-1005 38 AN-1010 38 AUTH System Messages - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 8
Chapter 5 AUTH-1016 42 AUTH-1017 43 AUTH-1018 43 AUTH-1020 43 AUTH-1022 44 AUTH-1023 44 AUTH-1025 45 AUTH-1026 45 AUTH-1027 45 AUTH-1028 46 AUTH-1029 46 AUTH-1030 46 AUTH-1031 47 AUTH-1032 47 AUTH-1033 47 AUTH-1034 48 AUTH-1035 48 AUTH-1036 48 AUTH-1037 49 AUTH-1038 49 AUTH-1039 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 9
Chapter 6 Chapter 7 ANV-1007 54 BKSW System Messages BKSW-1003 57 BL System Messages BL-1000 59 BL-1001 59 BL-1002 59 BL-1003 60 BL-1004 60 BL-1006 60 BL-1007 61 BL-1008 61 BL-1009 61 BL-1010 62 BL-1011 62 BL-1012 62 BL-1013 63 BL-1014 63 BL-1015 64 BL-1016 64 BL-1017 65 BL-1018 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 10
BL-1032 69 BL-1033 69 BL-1034 70 BL-1035 70 BL-1036 70 BL-1037 71 BL-1038 71 BL-1039 71 BL-1041 71 BL-1045 72 BL-1046 72 Chapter 8 BLL System Messages BLL-1000 73 Chapter 9 BLS System Messages BLS-1000 75 BLS-1001 75 BLS-1002 75 BLS-1003 75 BLS-1004 76 BLS-1005 76 Chapter 10 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 11
12 CDR System Messages CDR-1001 87 CDR-1002 87 CDR-1003 87 CDR-1004 88 CDR-1005 88 CDR-1006 88 Chapter 13 CEE CONFIG System Messages CCFG-1001 89 CCFG-1002 89 CCFG-1003 89 CCFG-1004 89 CCFG-1005 90 CCFG-1006 90 CCFG-1007 90 CCFG-1008 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 12
Chapter 15 CHASSIS System Messages CHASSIS-1002 95 CHASSIS-1003 95 CHASSIS-1004 95 CHASSIS-1005 96 Chapter 16 CNM System Messages CNM-1001 97 CNM-1002 97 CNM-1003 97 CNM-1004 97 CNM-1005 98 CNM-1006 98 CNM-1007 98 CNM-1008 98 CNM-1009 99 CNM-1010 99 CNM-1011 99 CNM-1012 99 CNM- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 13
Fabric OS Message Reference 53-1001767-01 CNM-1031 104 CNM-1032 104 CNM-1033 105 CNM-1034 105 CNM-1035 105 CNM-1036 105 CNM-1037 106 CNM-1038 106 CNM-1039 106 CNM-1040 106 CNM-1041 107 CNM-1042 107 CNM-1043 107 CNM-1044 107 CNM-1045 108 CNM-1046 108 CNM-1047 108 CNM-1048 108 CNM- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 14
CNM-3006 113 CNM-3007 114 CNM-3008 114 CNM-3009 114 CNM-3010 114 CNM-3011 115 CNM-3012 115 Chapter 17 CONF System Messages CONF-1000 117 CONF-1001 117 CONF-1020 117 CONF-1021 118 CONF-1022 118 CONF-1023 118 CONF-1024 118 CONF-1030 119 CONF-1031 119 CONF-1032 119 CONF-1040 119 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 15
CVLC-1011 126 CVLC-1012 126 CVLC-1013 126 CVLC-1014 126 CVLC-1015 127 CVLC-1016 127 CVLC-1017 127 CVLC-1018 127 CVLC-1019 128 CVLC-1020 128 CVLC-1021 128 CVLC-1022 129 CVLC-1023 129 CVLC-1024 129 CVLC-1025 129 CVLC-1026 130 CVLC-1027 130 CVLC-1028 130 CVLC-1029 130 CVLC-1030 131 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 16
CVLM-1011 135 CVLM-1012 135 CVLM-3001 136 CVLM-3002 136 CVLM-3003 136 CVLM-3004 136 CVLM-3005 137 CVLM-3006 137 CVLM-3007 137 CVLM-3008 137 CVLM-3009 138 CVLM-3010 138 CVLM-3011 138 CVLM-3012 138 CVLM-3013 139 CVLM-3014 139 CVLM-3015 139 CVLM-3016 140 CVLM-3017 140 CVLM-3018 140 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 17
DOT1-1006 146 DOT1-1007 146 DOT1-1008 146 DOT1-1009 147 DOT1-1010 147 Chapter 22 EM System Messages EM-1001 149 EM-1002 149 EM-1003 149 EM-1004 150 EM-1005 150 EM-1006 151 EM-1007 151 EM-1008 151 EM-1009 152 EM-1010 152 EM-1011 152 EM-1012 152 EM-1013 153 EM-1014 153 EM-1015 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 18
EM-1044 159 EM-1045 160 EM-1046 160 EM-1047 160 EM-1048 161 EM-1049 161 EM-1050 161 EM-1051 162 EM-1057 162 EM-1058 162 EM-1059 162 EM-1060 163 EM-1061 163 EM-1062 163 EM-1063 164 EM-1064 164 EM-1065 164 EM-1066 164 EM-1067 165 EM-1068 165 EM-1069 165 EM-1070 166 EM-2003 166 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 19
ESW-1006 170 ESW-1007 170 ESW-1008 171 Chapter 25 EVMD System Messages EVMD-1001 173 Chapter 26 FABR System Messages FABR-1001 175 FABR-1002 175 FABR-1003 175 FABR-1004 176 FABR-1005 176 FABR-1006 176 FABR-1007 177 FABR-1008 177 FABR-1009 177 FABR-1010 178 FABR-1011 178 FABR-1012 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 20
FABR-1035 184 FABR-1036 184 FABR-1037 184 FABR-1038 185 FABR-1039 185 FABR-1040 185 FABR-1041 186 FABR-1043 186 FABR-1044 186 FABR-1045 186 FABR-1046 187 FABR-1047 187 FABR-1048 187 FABR-1049 188 Chapter 27 FABS System Messages FABS-1001 189 FABS-1002 189 FABS-1004 189 FABS-1005 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 21
Chapter 30 FCIP System Messages FCIP-1000 199 FCIP-1001 199 FCIP-1002 199 FCIP-1003 199 FCIP-1004 200 Chapter 31 FCOE System Messages FCOE-1001 201 FCOE-1002 201 FCOE-1003 201 FCOE-1004 201 FCOE-1005 202 FCOE-1006 202 FCOE-1007 202 FCOE-1008 202 FCOE-1009 203 FCOE-1010 203 FCOE- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 22
FCOE-1031 208 FCOE-1032 208 FCOE-1033 208 FCOE-1034 209 FCOE-1035 209 FCOE-1036 209 Chapter 32 FCPD System Messages FCPD-1001 211 FCPD-1002 211 FCPD-1003 211 Chapter 33 FCPH System Messages FCPH-1001 213 FCPH-1002 213 Chapter 34 FCR System Messages FCR-1001 215 FCR-1002 215 FCR- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 23
Fabric OS Message Reference 53-1001767-01 FCR-1024 221 FCR-1025 221 FCR-1026 221 FCR-1027 221 FCR-1028 222 FCR-1029 222 FCR-1030 223 FCR-1031 223 FCR-1032 223 FCR-1033 223 FCR-1034 224 FCR-1035 224 FCR-1036 224 FCR-1037 224 FCR-1038 225 FCR-1039 225 FCR-1040 225 FCR-1041 225 FCR- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 24
FCR-1068 231 FCR-1069 231 FCR-1070 232 FCR-1071 232 FCR-1072 232 FCR-1073 233 FCR-1074 233 FCR-1075 233 FCR-1076 234 FCR-1077 234 FCR-1078 234 FCR-1079 234 FCR-1080 235 FCR-1081 235 FCR-1082 235 FCR-1083 236 FCR-1084 236 FCR-1085 236 FCR-1086 236 FCR-1087 237 FCR-1088 237 FCR- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 25
Fabric OS Message Reference 53-1001767-01 FICN-1014 243 FICN-1015 243 FICN-1016 243 FICN-1017 243 FICN-1018 244 FICN-1019 244 FICN-1020 244 FICN-1021 245 FICN-1022 245 FICN-1023 245 FICN-1024 246 FICN-1025 246 FICN-1026 246 FICN-1027 246 FICN-1028 247 FICN-1029 247 FICN-1030 247 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 26
FICN-1051 253 FICN-1052 254 FICN-1053 254 FICN-1054 254 FICN-1055 254 FICN-1056 255 FICN-1057 255 FICN-1058 255 FICN-1059 256 FICN-1060 256 FICN-1061 256 FICN-1062 256 FICN-1063 257 FICN-1064 257 FICN-1065 257 FICN-1066 258 FICN-1067 258 FICN-1068 258 FICN-1069 258 FICN-1070 259 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 27
Chapter 36 FICU System Messages FICU-1001 265 FICU-1002 265 FICU-1003 265 FICU-1004 266 FICU-1005 266 FICU-1006 266 FICU-1007 267 FICU-1008 267 FICU-1009 267 FICU-1010 268 FICU-1011 268 FICU-1012 268 FICU-1013 268 FICU-1014 269 FICU-1015 269 FICU-1016 269 FICU-1017 269 FICU-1018 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 28
FSPF-1005 278 FSPF-1006 278 FSPF-1007 278 FSPF-1008 278 Chapter 40 FSS System Messages FSS-1001 281 FSS-1002 281 FSS-1003 281 FSS-1004 282 FSS-1005 282 FSS-1006 282 FSS-1007 282 FSS-1008 283 FSS-1009 283 FSS-1010 283 FSS-1011 284 Chapter 41 FSSM System Messages FSSM-1002 285 FSSM - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 29
Fabric OS Message Reference 53-1001767-01 FW-1039 291 FW-1040 291 FW-1041 291 FW-1042 292 FW-1043 292 FW-1044 292 FW-1045 293 FW-1046 293 FW-1047 293 FW-1048 294 FW-1049 294 FW-1050 294 FW-1051 294 FW-1052 295 FW-1113 295 FW-1114 295 FW-1115 296 FW-1116 296 FW-1117 296 FW-1118 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 30
FW-1136 303 FW-1137 303 FW-1138 303 FW-1139 303 FW-1140 304 FW-1160 304 FW-1161 304 FW-1162 305 FW-1163 305 FW-1164 306 FW-1165 306 FW-1166 306 FW-1167 307 FW-1168 307 FW-1169 307 FW-1170 307 FW-1171 308 FW-1172 308 FW-1173 308 FW-1174 309 FW-1175 309 FW-1176 309 FW-1177 310 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 31
Fabric OS Message Reference 53-1001767-01 FW-1192 314 FW-1193 314 FW-1194 315 FW-1195 315 FW-1196 315 FW-1197 316 FW-1198 316 FW-1199 316 FW-1200 316 FW-1201 317 FW-1202 317 FW-1203 317 FW-1204 318 FW-1205 318 FW-1206 318 FW-1207 318 FW-1244 319 FW-1245 319 FW-1246 319 FW-1247 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 32
FW-1332 325 FW-1333 326 FW-1335 326 FW-1336 326 FW-1337 327 FW-1338 327 FW-1339 327 FW-1340 328 FW-1341 328 FW-1342 328 FW-1343 329 FW-1349 329 FW-1350 329 FW-1352 330 FW-1353 330 FW-1354 331 FW-1355 331 FW-1356 331 FW-1357 332 FW-1358 332 FW-1359 332 FW-1364 333 FW-1365 333 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 33
Fabric OS Message Reference 53-1001767-01 FW-1400 338 FW-1401 338 FW-1402 339 FW-1403 339 FW-1404 339 FW-1405 339 FW-1406 340 FW-1407 340 FW-1408 340 FW-1424 340 FW-1425 341 FW-1426 341 FW-1427 341 FW-1428 342 FW-1429 342 FW-1430 342 FW-1431 342 FW-1432 343 FW-1433 343 FW-1434 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 34
FW-1512 348 FW-1513 349 FW-1514 349 FW-1515 349 FW-1516 350 FW-1517 350 FW-1518 350 FW-1519 351 FW-1520 351 FW-1521 351 FW-1522 352 FW-1523 352 FW-1524 352 FW-1525 353 FW-1526 353 FW-1527 353 FW-1528 353 FW-1529 354 FW-1530 354 FW-1531 354 FW-1532 355 FW-1533 355 FW-1534 355 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 35
Chapter 43 HAM System Messages HAM-1001 361 HAM-1002 361 HAM-1004 361 HAM-1005 362 HAM-1006 362 HAM-1007 363 HAM-1008 363 HAM-1009 363 HAM-1010 364 HAM-1011 364 HAM-1012 364 HAM-1013 364 HAM-1014 365 Chapter 44 HAMK System Messages HAMK-1001 367 HAMK-1002 367 HAMK-1003 367 HAMK- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 36
HIL-1301 374 HIL-1302 374 HIL-1303 374 HIL-1304 374 HIL-1305 375 HIL-1306 375 HIL-1307 375 HIL-1308 375 HIL-1309 376 HIL-1310 376 HIL-1311 376 HIL-1401 376 HIL-1402 377 HIL-1403 377 HIL-1404 377 HIL-1501 377 HIL-1502 378 HIL-1503 378 HIL-1504 378 HIL-1505 379 HIL-1506 379 HIL- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 37
Chapter 47 HMON System Messages HMON-1001 385 Chapter 48 HSL System Messages HSL-1000 387 HSL-1001 387 HSL-1002 387 HSL-1003 387 HSL-1004 388 HSL-1004 388 HSL-1005 388 HSL-1006 388 HSL-1007 389 Chapter 49 HTTP System Messages HTTP-1001 391 HTTP-1002 391 HTTP-1003 391 Chapter 50 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 38
Chapter 53 IPAD System Messages IPAD-1000 401 IPAD-1001 401 Chapter 54 IPS System Messages IPS-1001 403 IPS-1002 403 IPS-1003 403 IPS-1004 403 IPS-1005 404 IPS-1006 404 Chapter 55 ISCS System Messages ISCS-1000 405 Chapter 56 ISNS System Messages ISNS-1001 407 ISNS-1002 407 ISNS- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 39
Chapter 58 KSWD System Messages KSWD-1001 413 KSWD-1002 413 Chapter 59 KTRC System Messages KTRC-1001 415 KTRC-1002 415 KTRC-1003 415 KTRC-1004 415 KTRC-1005 416 Chapter 60 L2SYS System Messages L2SS-1001 417 L2SS-1002 417 L2SS-1003 417 L2SS-1004 417 L2SS-1005 418 L2SS-1006 418 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 40
LOG-1003 426 Chapter 65 LSDB System Messages LSDB-1001 427 LSDB-1002 427 LSDB-1003 427 LSDB-1004 428 Chapter 66 MFIC System Messages MFIC-1001 429 MFIC-1002 429 MFIC-1003 429 Chapter 67 MPTH System Messages MPTH-1001 431 MPTH-1002 431 MPTH-1003 431 Chapter 68 MQ System Messages MQ - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 41
Chapter 70 MSTP System Messages MSTP-1001 441 MSTP-1002 441 MSTP-1003 441 MSTP-2001 441 MSTP-2002 442 MSTP-2003 442 MSTP-2004 442 MSTP-2005 442 MSTP-2006 443 Chapter 71 NBFS System Messages NBFS-1001 445 NBFS-1002 445 NBFS-1003 446 Chapter 72 NS System Messages NS-1001 447 NS-1002 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 42
NSM-1009 453 NSM-1010 453 NSM-1011 453 NSM-1012 453 NSM-1013 454 NSM-1014 454 NSM-1015 454 NSM-1016 454 NSM-1017 455 NSM-1018 455 NSM-1019 455 NSM-1020 455 NSM-1021 456 NSM-1022 456 Chapter 74 ONM System Messages ONMD-1000 457 ONMD-1001 457 ONMD-1002 457 ONMD-1003 457 ONMD-1004 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 43
PDM-1017 463 PDM-1019 463 PDM-1020 463 PDM-1021 463 PDM-1022 464 PDM-1023 464 PDM-1024 464 Chapter 76 PDTR System Messages PDTR-1001 465 PDTR-1002 465 Chapter 77 PLAT System Messages PLAT-1000 467 PLAT-1001 467 PLAT-1002 467 PLAT-1003 468 Chapter 78 PMGR System Messages PMGR-1001 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 44
PORT-1009 474 PORT-1010 475 Chapter 80 PS System Messages PS-1000 477 PS-1001 477 PS-1002 477 PS-1003 477 PS-1004 478 PS-1005 478 PS-1006 478 PS-1007 479 Chapter 81 PSWP System Messages PSWP-1001 481 PSWP-1002 481 PSWP-1003 481 PSWP-1004 482 PSWP-1005 482 PSWP-1006 482 PSWP-1007 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 45
RCS-1002 487 RCS-1003 487 RCS-1004 488 RCS-1005 488 RCS-1006 488 RCS-1007 489 RCS-1008 489 Chapter 84 RKD System Messages RKD-1001 491 RKD-1002 491 RKD-1003 491 RKD-1004 492 RKD-1005 492 Chapter 85 RMOND System Messages RMON-1001 493 RMON-1002 493 Chapter 86 RPCD System Messages - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 46
Chapter 90 SEC System Messages SEC-1001 503 SEC-1002 503 SEC-1003 504 SEC-1005 504 SEC-1006 504 SEC-1007 505 SEC-1008 505 SEC-1009 505 SEC-1010 505 SEC-1016 506 SEC-1022 506 SEC-1024 506 SEC-1025 507 SEC-1026 507 SEC-1028 507 SEC-1029 508 SEC-1030 508 SEC-1031 508 SEC-1032 508 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 47
Fabric OS Message Reference 53-1001767-01 SEC-1053 514 SEC-1054 514 SEC-1055 514 SEC-1056 515 SEC-1057 515 SEC-1059 515 SEC-1062 515 SEC-1063 516 SEC-1064 516 SEC-1065 516 SEC-1069 516 SEC-1071 517 SEC-1072 517 SEC-1073 517 SEC-1074 517 SEC-1075 518 SEC-1076 518 SEC-1077 518 SEC- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 48
SEC-1097 524 SEC-1098 524 SEC-1099 525 SEC-1100 525 SEC-1101 525 SEC-1102 525 SEC-1104 526 SEC-1105 526 SEC-1106 526 SEC-1107 527 SEC-1108 527 SEC-1110 527 SEC-1111 527 SEC-1112 528 SEC-1113 528 SEC-1114 528 SEC-1115 529 SEC-1116 529 SEC-1117 529 SEC-1118 529 SEC-1119 530 SEC- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 49
Fabric OS Message Reference 53-1001767-01 SEC-1155 535 SEC-1156 535 SEC-1157 535 SEC-1158 536 SEC-1159 536 SEC-1160 536 SEC-1163 536 SEC-1164 537 SEC-1165 537 SEC-1166 537 SEC-1167 538 SEC-1168 538 SEC-1170 538 SEC-1171 539 SEC-1172 539 SEC-1173 539 SEC-1174 539 SEC-1175 540 SEC- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 50
SEC-1198 545 SEC-1199 546 SEC-1200 546 SEC-1201 546 SEC-1202 547 SEC-1203 547 SEC-1250 547 SEC-1251 547 SEC-1253 548 SEC-1300 548 SEC-1301 548 SEC-1302 549 SEC-1303 549 SEC-1304 549 SEC-1305 549 SEC-1306 550 SEC-1307 550 SEC-1308 550 SEC-1309 551 SEC-1310 551 SEC-1311 551 SEC- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 51
SEC-1328 556 SEC-1329 556 SEC-1330 556 SEC-1331 557 SEC-1332 557 SEC-1333 557 SEC-3005 557 SEC-3035 558 SEC-3036 558 SEC-3037 558 SEC-3038 559 SEC-3039 559 SEC-3050 559 SEC-3051 559 SEC-3061 560 SEC-3062 560 SEC-3063 560 SEC-3064 560 SEC-3065 561 SEC-3066 561 SEC-4001 561 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 52
SNMP-1005 568 SNMP-1006 568 SNMP-1007 568 SNMP-1008 569 Chapter 93 SPC System Messages SPC-1001 571 SPC-1002 571 SPC-1003 571 SPC-2001 572 SPC-2002 572 SPC-2003 572 SPC-2004 572 SPC-2005 573 SPC-2006 573 SPC-2007 573 SPC-2008 573 SPC-2009 574 SPC-2010 574 SPC-2011 574 SPC-2012 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 53
Chapter 94 SPM System Messages SPM-1001 581 SPM-1002 581 SPM-1003 581 SPM-1004 581 SPM-1005 582 SPM-1006 582 SPM-1007 582 SPM-1008 582 SPM-1009 583 SPM-1010 583 SPM-1011 583 SPM-1012 583 SPM-1013 584 SPM-1014 584 SPM-1015 584 SPM-3001 584 SPM-3002 585 SPM-3003 585 SPM-3004 585 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 54
SPM-3022 590 SPM-3023 590 SPM-3024 590 SPM-3025 590 SPM-3026 591 SPM-3027 591 SPM-3028 591 SPM-3029 591 Chapter 95 SS System Messages SS-1000 593 SS-1001 593 SS-1002 593 SS-1003 594 SS-1004 594 SS-1005 594 SS-1006 594 SS-1007 595 SS-1008 595 Chapter 96 SSM System Messages SSMD- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 55
SSMD-1211 601 SSMD-1212 601 SSMD-1213 601 SSMD-1214 602 SSMD-1215 602 SSMD-1216 602 SSMD-1217 603 SSMD-1300 603 SSMD-1301 603 SSMD-1302 603 SSMD-1303 604 SSMD-1304 604 SSMD-1305 604 SSMD-1306 604 SSMD-1307 605 SSMD-1308 605 SSMD-1309 605 SSMD-1310 605 SSMD-1311 606 SSMD-1312 606 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 56
SULB-1020 616 SULB-1021 616 SULB-1022 617 SULB-1023 617 SULB-1024 617 SULB-1025 618 SULB-1026 618 SULB-1030 618 SULB-1031 618 SULB-1032 619 SULB-1033 619 SULB-1034 619 SULB-1035 619 SULB-1036 620 SULB-1037 620 SULB-1038 620 SULB-1039 621 SULB-1040 621 Chapter 98 SWCH System - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 57
SWCH-1019 628 SWCH-1020 628 SWCH-1021 628 Chapter 99 SYSC System Messages SYSC-1001 629 SYSC-1002 629 SYSC-1003 629 SYSC-1004 630 SYSC-1005 630 Chapter 100 SYSM System Messages SYSM-1001 631 SYSM-1002 631 SYSM-1003 631 SYSM-1004 632 SYSM-1005 632 SYSM-1006 632 SYSM-1007 632 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 58
Chapter 103 TRCK System Messages TRCK-1001 639 TRCK-1002 639 TRCK-1003 639 TRCK-1004 639 TRCK-1005 640 TRCK-1006 640 Chapter 104 TS System Messages TS-1001 641 TS-1002 641 TS-1006 642 TS-1007 642 TS-1008 642 Chapter 105 UCST System Messages UCST-1003 643 UCST-1007 643 UCST-1020 643 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 59
XTUN-1001 649 XTUN-1002 649 XTUN-1003 649 XTUN-1004 650 XTUN-1998 650 XTUN-1999 650 XTUN-2000 650 XTUN-2001 651 XTUN-2002 651 XTUN-2003 651 XTUN-2004 651 XTUN-2005 652 Chapter 109 ZEUS System Messages ZEUS-1001 653 Chapter 110 ZOLB System Messages ZOLB-1001 655 Chapter 111 ZONE System - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 60
ZONE-1026 662 ZONE-1027 663 ZONE-1028 663 ZONE-1029 663 ZONE-1030 664 ZONE-1031 664 ZONE-1032 664 ZONE-1033 664 ZONE-1034 665 ZONE-1035 665 ZONE-1036 665 ZONE-1037 666 ZONE-1038 666 ZONE-1039 666 ZONE-1040 666 ZONE-1041 667 ZONE-1042 667 ZONE-1043 667 ZONE-1044 667 ZONE-1045 668 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 61
AG-1034 675 AG-1035 675 AG-1036 675 AG-1037 676 Chapter 113 AUDIT AN System Messages AN-1003 677 AN-1004 677 AN-1005 677 AN-1006 678 AN-1010 678 Chapter 114 AUDIT AUTH System Messages AUTH-1045 679 AUTH-1046 679 AUTH-1047 679 AUTH-3001 680 AUTH-3002 680 AUTH-3003 680 AUTH-3004 680 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 62
CNM-3009 687 CNM-3010 687 CNM-3011 687 CNM-3012 688 Chapter 117 AUDIT CONF System Messages CONF-1000 689 CONF-1001 689 CONF-1020 689 CONF-1022 690 CONF-1042 690 CONF-1043 690 Chapter 118 AUDIT CVLM System Messages CVLM-3001 691 CVLM-3002 691 CVLM-3003 691 CVLM-3004 692 CVLM-3005 692 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 63
CVLM-3024 697 CVLM-3025 697 CVLM-3026 698 CVLM-3027 698 CVLM-3028 698 Chapter 119 AUDIT FCIP System Messages FCIP-1002 699 FCIP-1003 699 Chapter 120 AUDIT FICU System Messages FICU-1011 701 FICU-1012 701 FICU-1019 701 FICU-1020 701 FICU-1021 702 Chapter 121 AUDIT FW System Messages FW- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 64
SEC-3004 712 SEC-3005 713 SEC-3006 713 SEC-3007 713 SEC-3008 714 SEC-3009 714 SEC-3010 714 SEC-3011 714 SEC-3012 715 SEC-3013 715 SEC-3014 715 SEC-3015 716 SEC-3016 716 SEC-3017 716 SEC-3018 717 SEC-3019 717 SEC-3020 717 SEC-3021 717 SEC-3022 718 SEC-3023 718 SEC-3024 718 SEC- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 65
SEC-3045 723 SEC-3046 723 SEC-3047 724 SEC-3048 724 SEC-3049 724 SEC-3050 724 SEC-3051 725 SEC-3061 725 SEC-3062 725 SEC-3063 725 SEC-3064 726 SEC-3065 726 SEC-3066 726 SEC-4001 726 Chapter 126 AUDIT SNMP System Messages SNMP-1004 729 SNMP-1005 729 SNMP-1006 729 Chapter 127 AUDIT - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 66
SPM-3017 735 SPM-3018 735 SPM-3019 735 SPM-3020 736 SPM-3021 736 SPM-3022 736 SPM-3023 736 SPM-3024 737 SPM-3025 737 SPM-3026 737 SPM-3027 737 SPM-3028 738 SPM-3029 738 Chapter 128 AUDIT SULB System Messages SULB-1001 739 SULB-1002 739 SULB-1003 739 SULB-1004 740 SULB-1009 740 SULB - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 67
SULB-1040 751 Chapter 129 AUDIT SWCH System Messages SWCH-1012 753 SWCH-1013 753 SWCH-1014 753 Chapter 130 AUDIT UCST System Messages UCST-1021 755 UCST-1022 755 UCST-1023 755 UCST-1024 756 UCST-1025 756 UCST-1026 756 UCST-1027 756 Chapter 131 AUDIT ZONE System Messages ZONE-3001 759 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 68
ZONE-3022 765 ZONE-3023 765 ZONE-3024 765 ZONE-3025 765 lxviii Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 69
of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for 6.4.0, documenting - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 70
Brocade 5460 • Brocade 5470 • Brocade 5480 • Brocade 7500 • Brocade 7500E • Brocade 7600 • Brocade 7800 • Brocade 8000 • Brocade 48000 • Brocade Encryption Switch • Brocade DCX Backbone • Brocade DCX-4S Backbone • Brocade VA-40FC What's new in this document The following changes have been made since - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 71
Messages" - "AUDIT SULB System Messages" - "SWCH System Messages" - "ZONE System Messages" For further information about new features and documentation updates for this release, refer to the release notes. Document conventions This section describes text formatting conventions and important notice - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 72
of user-manipulated GUI this guide are presented manual follows these conventions: command --option, option -argument, arg [ ] variable ... value | Commands are printed in bold. Command options are printed in bold. Arguments. Optional element. Variables are printed in italics. In the help pages - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 73
cause damage to hardware, firmware, software, or data. visit the Storage Networking Industry Association online user ID and password. White papers, online demonstrations, and data sheets are available through the Brocade website at: http://www.brocade.com/products-solutions/products/index.page - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 74
software version, if applicable • Error numbers and messages received • supportSave command output • Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 75
the chassis. • If you cannot use the licenseIdShow command because the switch is inoperable, you can get the WWN from the same place as completeness of this document. However, if you find an error or an omission, or you think that a topic needs page number and your suggestions for improvement. Fabric - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 76
lxxvi Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 77
and Configuring System Message Logs 4 •Reading a RAS System Message 8 •Responding to a System Message 11 •System Module Descriptions 13 Overview of System Messages This guide supports Fabric OS v6.4.0 and documents system messages that can help you diagnose and fix problems with a switch or - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 78
Daemon (syslogd)" on page 3 for more information. Event Auditing Event auditing is designed to support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads, and certain types of - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 79
other operating system that supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade DCX, 24000 and 48000, each CP has a unique error log, depending on which - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 80
the Fabric OS Administrator's Guide for information on interpreting results of the portLogDump command. Port log functionality is completely separate from the system message log. Port logs are typically used to troubleshoot device connections. Viewing and Configuring System Message Logs This section - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 81
(Power-On Self-Test) configuration. errClear Clears all error log messages for all switch instances on this control processor (CP). errDelimterSet Sets the error log start and end delimiter for messages pushed to the console. errDump Displays the entire error log, without page breaks. Use the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 82
service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogDIpAdd Adds an IP address as a recipient of system messages. syslogDIpRemove Removes an IP address as a recipient of system messages. syslogDIpShow Views the currently configured - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 83
are cleared. For products that have multiple processors, this command only clears the error logs of the processor it is executed from. Configuring Event Auditing To configure event auditing: 1. Configure the event classes you wish to audit: switch:admin> auditcfg --class 1,2,3,4,5 Audit filter is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 84
Number>, ,,, The following example shows a sample message from the error log: 2009/02/10-14:18:04, [SS-1000], 88, SLOT 6 | FFDC | CHASSIS, INFO, ESNSVT_DCX, supportSave has uploaded support information to the host with IP address 168.159 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 85
manual. Note that not all message numbers are used; there can be gaps in the numeric message sequence. Sequence Number The error reset to 1 using the errClear command. The sequence number is persistent across power cycles and switch was generated by the default switch instance. CHASSIS is the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 86
Level Event Class User ID Role IP Address Interface Application Name Admin Domain Identifies the message as an Audit message. The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL" setting. The - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 87
show the logical switch name. The defined switch name or the chassis name of the switch. This value is guidelines for troubleshooting. For all cases, you should look at each specific error message description Message • Gathering Information About the Problem • Support • Panic Dump and Core Dump - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 88
the error • Message text • Probable cause • Recommended action • Message severity Gathering Information About the Problem Common steps and questions to ask yourself when troubleshooting a system message are as follows: 1. What is the current Fabric OS level? 2. What is the switch hardware version - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 89
Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem. This section describes those files and how to access and/or save the information for support personnel. Panic Dump and Core Dump Files The Fabric OS creates panic dump files and core files - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 90
platforms. Fibre Channel over IP port configuration message over Spike and Striker Blade. Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP). Condor2 error messages indicate problems with the Condor2 ASIC driver module of the Fabric - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 91
lists to all switches in the fabric. Fabric OS system driver module. Firmware blade compatibility errors with control processor (CP). Fibre Channel over IP port configuration messages over Sprint and Marathon Blade. Fibre Channel miscellaneous messages relate to problems with the physical layer - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 92
a service. A component is a module in the Fabric OS, implementing a related set of functionality. A service is configurations not only switch wide, but also fabric wide. It keeps track iSCSI VT status and updates VT status to BP. System messages generated by the IP admin demon. Fibre Channel over IP - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 93
Monitor (emd) • EVM daemon (evmd) • Exchange Service Support daemon (essd) • FA-API rpc daemon (rpcd) error messages indicate problems with the LANCE module of the Fabric OS. LFM error messages indicate problems with the logical fabric manager module that is responsible for making a logical switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 94
to dynamically compute a broadcast tree Management Service enables the user to problems. A group of messages relating to logical switch creation, deletion and configuration. PORT error messages refer to the front-end user ports on the switch. Front-end user ports are directly accessible by users - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 95
operation errors, and external attack. Simple Network Management Protocol is a universally supported low-level protocol that allows simple get, get next, and set requests to go to the switch (acting as an SNMP agent). It also allows the switch to send traps to the defined and configured management - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 96
sent. For information on configuring the track change feature, refer to the Fabric OS Command Reference or the Fabric OS Administrator's Guide. Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the clock time on the principal switch. UCST is a part of - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 97
Messages 59 •BLL System Messages 73 •BLS System Messages 75 •BM System Messages 77 •C2 System Messages 83 •CDR System Messages 87 •CEE CONFIG System Messages 89 •CER System Messages 93 •CHASSIS System Messages 95 •CNM System Messages 97 •CONF System Messages 117 •CTAP System Messages 121 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 98
387 •HTTP System Messages 391 •IBD System Messages 393 •IBPD System Messages 395 •ICPD System Messages 397 •IPAD System Messages 401 •IPS System Messages 403 •ISCS System Messages 405 •ISNS System Messages 407 •KAC System Messages 411 •KSWD System Messages 413 •KTRC System Messages - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 99
•PDM System Messages 459 •PDTR System Messages 465 •PLAT System Messages 467 •PMGR System Messages 469 •PORT System Messages 473 •PS System Messages 477 •PSWP System Messages 481 •RAS System Messages 483 •RCS System Messages 487 •RMOND System Messages 493 •RKD System Messages 491 •RPCD - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 100
24 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 101
Action Check whether or not an alternate N_Port is configured. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG-1003 Message , [AG-1003 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 102
N_Port. Recommended Action Check the configuration of the fabric switch. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AG-1005 Message , [AG - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 103
Recommended Action Please check the configuration of the fabric switch connected to the Access Gateway. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING AG - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 104
service parameter request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch connected to the Access Gateway. If the message persists, run the supportFtp command (as needed) to set ag --mapShow to display updated F_Port-to-N_Port mapping. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 105
configured or all N_Ports are currently offline. Recommended Action Check whether or not any other N_Port is configured. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportsave command and contact your switch service updated - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 106
configured as N_Ports. Ensure that the host is connected to an F_port. Severity ERROR switch has come online or some new N_Port/F_Port has come online. Recommended Run the ag --mapshow command to display the updated supported configuration. Recommended Action Change the preferred N_Port settings - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 107
> mapped to offline N_Port is failed over to its preferred N_Port . Probable Cause Indicates the specified N_Port has failed to come online. The F_Port mapped to this N_Port had its preferred set and is online. Recommended Run the ag --mapshow command to display updated F_Port -to - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 108
. Recommended Action Run configure CLI on AG switch and increase the number of allowed logins on this port. If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 109
unreliable. Probable Cause Indicates that the port goes online and offline very often. Recommended No action is required. Action Severity WARNING updated for N_Port () . Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the configuration file has been updated - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 110
-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is system-name>,Trunked N_Port () going offline, if switchshow CLI for the connected fabric switch port displays Persistently disabled: Area has - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 111
on the connected fabric switch port displays 'Persistently ERROR AG-1039 Message , [AG-1039], ,, INFO, ,F-Port was reset because a WWN mapped device using it, through N-Port - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 112
2 AG-1039 36 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 113
cycle the Action switch. Severity ERROR AN-1002 Message , [AN-1002], ,, ERROR, , Failed to initialize; rc = Probable Cause Indicates that the initialization of the 'trafd' daemon has failed. Recommended Download a new firmware version using the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 114
-name>, Severe latency bottleneck detected at Slot port . Probable Cause Indicates a credit loss. Recommended Contact your vendor's customer support for assistance. Action Severity WARNING 38 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 115
contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set to . Probable Cause Indicates that an authentication configuration value was set to the specified - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 116
Action Run the firmwareDownload command to reinstall the firmware. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1006 Message , [AUTH-1006], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 117
an internal problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 118
request. Recommended Action Usually this problem is transient. The authentication might set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1016 Message , [AUTH-1016], , FFDC, ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 119
commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1020 Message , [AUTH-1020], ,, INFO, , Failed - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 120
persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1023 Message , [AUTH-1023], ,, ERROR, , Failed to during - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 121
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR Usually this problem is transient switch does not support the specified authentication value. Recommended Action Check the authentication configuration and reset the supported - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 122
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1028 Message , [AUTH-1028], ,, ERROR phase failed. Recommended Action Usually this problem is transient. The authentication might fail. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 123
contact your switch service provider. Severity ERROR AUTH-1033 Message Probable Cause , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch . Indicates that an entity was not configured in the switch connection - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 124
. This error usually relates to internal failure. Recommended Action Usually this problem is transient set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1036 Message , [AUTH-1036], ,, ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 125
, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1038 Message , [AUTH-1038], ,, ERROR, , Failed to retrieve certificate during - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 126
OFF. Probable Cause Indicates that the local switch has rejected the authentication because the switch policy is turned off. If the neighboring switch has a strict (ON) switch policy, the light will go off due to conflicting configuration settings. Otherwise E_Port will form without authentication - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 127
will be defaulted to OFF, and switch will not participate in Diffie Hellman - challenge handshake authentication protocol (DH-CHAP) authentication with devices. Recommended Try setting the device authentication policy manually using the authUtil command. Action Severity ERROR AUTH-1044 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 128
values for Operation type can be "set" or "remove". Recommended Action Retry the secAuthCertificate command. Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR 52 Fabric OS Message Reference 53 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 129
and slotPowerOn commands on the blade to recover the system. For a non-bladed system, perform the fastBoot command on the switch to recover the system. Severity ERROR ANV-1003 Message , [ANV-1003], ,, CRITICAL, , ,: HW ASIC Chip - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 130
the next maintenance window. If the problem persists, replace the CP blade. Action Severity ERROR ANV-1006 Message , [ANV- chip error type>. Probable Cause Indicates that Anvil Pass 1 is out of free buffer which might cause a chip fault. Recommended Reconfigure the testing setup. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 131
Severity CRITICAL ANV-1007 5 Fabric OS Message Reference 55 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 132
5 ANV-1007 56 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 133
if any core files were created. If a core file is found, run supportFtp to send all the core files to a secure server location. Copy the error message and any core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 57 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 134
6 BKSW-1003 58 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 135
the switch has completed does not have hardware problems. To run this Manual for more information on this command. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Additional blade fault messages precede and follow this error, providing more information. See other error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 136
problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test was not faulted due to a user setting. Recommended Action Restart or power . Probable Cause Indicates that the errors (mostly synchronization errors) on this blade are harmless. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 137
the blade. Run the systemVerification command to verify that the blade does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 138
in slot inconsistent with the hardware settings. Probable Cause Indicates that a failover occurred while switch does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 139
to a user port number. Recommended Action Make sure to capture the console output during this process. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot the switch. Run the systemVerification command to determine if there is a hardware error. To run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 140
switch operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this number might not correspond to a user On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 141
BL-1017 7 Run the systemVerification command to verify that the blade does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 142
switch does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. Additional fault messages precede and follow this error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 143
/FCIP Virtualization ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 144
port went offline during the warm recovery of the switch. The switch will reboot and start a cold recovery. Recommended Collect supportSave information, then restart the switch and run the diagPost command to ensure Action Power-On Self-Test (POST) is enabled. If the problem persists, replace - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 145
All GigE/FCIP Virtualization/FC Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 146
for disable messages from the user ports after disabling the ports. Recommended Action Restart or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 147
it> in slot as it does not support this mode. Probable Cause Indicates that the blade does not support dynamic area mode on default switch. Recommended Turn off the dynamic area mode through Configure CLI. Action Severity CRITICAL Fabric OS Message Reference 71 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 148
that has the mini SFP+ that does not support it>. Probable Cause Indicates that the mini (form factor) SFP+ is supported only by a certain type of blade ( computed one or there is problem accessing the data. Recommended Try reseating the SFP, if problem persists replace it. Action Severity ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 149
driver detected Slot port as faulty (reason: ) Probable Cause Indicates a blade regulation problem Wait for Open init state • 20 = TX parity error • 21 = RAM parity error • 22 = BISR or RAMINIT error Recommended Action Make sure the blade is seated correctly. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 150
8 BLL-1000 Severity CRITICAL 74 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 151
switch. Recommended Retry the command. Action Severity CRITICAL BLS-1002 Message , [BLS-1002], ,, INFO, , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec or IKE policy was added and the configuration file was updated. Recommended - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 152
policy was deleted and the configuration file was updated. Recommended No action is required support the Tape Read Pipelining feature. Recommended No action is required. Action Severity INFO BLS-1005 Message , [BLS-1005], ,, ERROR, , S,P - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 153
determine whether a non-disruptive firmware download is supported between the revisions. Because the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If needed, send the AP blade back to the factory for a firmware update. Severity ERROR BM-1002 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 154
version of the firmware loaded. Recommended No action is required. The blade will automatically download the updated firmware. Action Severity INFO configured. Persistently disabling all ports for blade in slot . Probable Cause Indicates the policy of the specified blade is set to - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 155
blade. On the Brocade Action 7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit. Severity WARNING BM-1010 Message , [BM-1010], ,, INFO, , Resetting port configuration and linkcost for all ports for blade in slot - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 156
action is required. The blade will automatically download the updated firmware. Action Severity INFO BM-1055 Message , [BM-1055], ,, WARNING, , Firmwaredownload timed-out for AP. Faulting switch. Probable Cause Indicates the firmwareDownload command on - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 157
on this switch. • The switch was configured under a different mode. Recommended Configure the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 158
10 BM-1058 82 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 159
ERROR, , Port port faulted due to SFP validation failure. Please check if the SFP is valid for the configuration. perform fastboot on the switch to recover the system. Severity ERROR C2-1004 Message , [C2-1004], ,, ERROR, , - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 160
a more detailed monitoring of internal hardware reported errors. There is no action required by the user at this time. If any actual hardware will be turned off at next port state change as it is not supported under this configuration. Probable Cause Indicates QoS will be turned off automatically - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 161
to be reset or replaced: fault1:, fault2: th2:0x. Probable Cause Indicates above normal errors observed data traffic. Recommended Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, Action replace the blade. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 162
11 C2-1011 86 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 163
and slotPowerOn commands on the blade to recover the system. For a non-bladed system, perform fastBoot command on the switch to recover the system. Severity ERROR CDR-1003 Message , [CDR-1003], , FFDC, CRITICAL, , , HW ASIC chip - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 164
. Severity ERROR CDR-1005 Message , [CDR-1005], ,, WARNING, , , : at next port state change, best effort QOS will be turned off automatically due to best effort is no longer supported under this configuration - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 165
Converged Enhanced Ethernet (CEE) configuration management daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CCFG-1002 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 166
Use the copy file startup-config command to restore the startup configuration from any backup Action retrieved on the server. Severity ERROR CCFG-1005 Message , [CCFG-1005], ,, INFO, , Startup configuration is updated. Probable Cause Indicates that the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 167
has failed. Recommended No action is required. Action Severity ERROR CCFG-1009 Message , [CCFG-1009], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 168
after system ready event. Recommended Run the slotpoweroff command followed by the slotpoweron command on the slot to retry bringing Action the slot online. Severity ERROR 92 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 169
CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended Action Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS on the active CP. Severity ERROR Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 170
14 CER-1001 94 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 171
command followed by the slotPowerOn Action command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR CHASSIS-1004 Message , [CHASSIS-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 172
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR 96 Fabric OS Message Reference 53 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 173
firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CNM-1003 Message , [CNM-1003], ,, WARNING, , Crypto device configuration between local switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 174
16 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [ - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 175
id>], ulen []. Probable Cause Indicates the client data update. Recommended No action is required. Action Severity INFO CNM-1011 Message Cause Indicates the node join timeout. Recommended Take the peer node offline, rejoin the node to the encryption group (EG). Action Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 176
16 CNM-1013 Recommended No action is required. Action Severity INFO CNM-1013 Message , [CNM-1013], ,, INFO, ,Posting event GL Node Split condition, isolating peer GL node . Probable Cause Indicates that the encryption group (EG) is split. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 177
INFO CNM-1017 Message , [CNM-1017], ,, INFO, ,Got JOIN REQUEST from un-recognized GL node [], configured GL node is []. Probable Cause Indicates a join request was received from an invalid group leader (GL) node. Recommended No action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 178
16 CNM-1021 Probable Cause Indicates that the Node Admission Control has failed. Recommended No action is required. Action Severity INFO CNM-1021 Message , [CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 179
Hdr version Expected Hdr version Node . Probable Cause Indicates that a version mismatch has occurred. Recommended Upgrade the firmware or delete the Node from the encryption group (EG). Action Severity INFO CNM-1027 Message , [CNM-1027], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 180
16 CNM-1029 Probable Cause Indicates that the certificate file for the node already exists. Recommended No action is required. Action Severity INFO CNM-1029 Message , [CNM-1029], ,, WARNING, , Certfile content does not match the cert sent by GL. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 181
16 CNM-1033 Probable Cause Indicates that there is a size mismatch between a node's certificate file and the certificate file received from the group leader. Recommended No action is required. Action Severity WARNING CNM-1033 Message , [CNM-1033], ,, WARNING, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 182
16 CNM-1037 Probable Cause Indicates an event is being posted to indicate that the cluster is in a converged state. Recommended No action is required. Action Severity INFO CNM-1037 Message , [CNM-1037], ,, INFO, , Split-Brain Arbitration lost!, minority - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 183
the update of the persistent database is complete. Recommended No action is required. Action Severity INFO CNM-1043 Message , [CNM-1043], ,, ERROR, , Received HBT from undefined node IpAddress [], WWN []. Possible configuration error. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 184
ERROR CNM-1045 Message , [CNM-1045], ,, ERROR, , Member node is having dual IP stack.Registering member node with dual IP -name>, Network Interface to Remote Node is . Probable Cause Indicates that the status of the network interface is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 185
to mismatch in Access Gateway Daemon (AGD) mode settings, rejecting node . Probable Cause Indicates mode mismatch between the switches like the Access Gateway mode mismatch. Recommended No action is required. Action Severity ERROR CNM-1051 Message , [CNM-1051], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 186
another encryption group (EG). Recommended No action is required. Action Severity ERROR CNM-1054 Message , [CNM-1054], ,, INFO, , Encryption Group database state with node ip , wwn . Probable Cause Indicates the status of the cluster - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 187
Severity INFO CNM-1057 Message , [CNM-1057], ,, INFO, , Posting event CNM_EVT_ONLINE Slot , Wwn , IP , flags . Probable Cause Indicates that the encryption engine (EE) is online in the encryption group (EG). Recommended No action is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 188
. Action Severity INFO CNM-1061 Message , [CNM-1061], ,, INFO, , IP of the switch changed from [] to []. Probable Cause Indicates that the switch IP has changed. Recommended No action is required. Action Severity INFO CNM-1062 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 189
Action Severity INFO CNM-3006 Message Probable Cause , [CNM-3006], ,, INFO, , Event: cryptocfg Status: success, Info: Heartbeat miss count set to . Indicates that the heartbeat miss value was set. Fabric OS Message Reference 113 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 190
[CNM-3007],,, INFO, , Event: cryptocfg Status: success, Info: Heartbeat timeout set to . Probable Cause Indicates that the heartbeat timeout value was set. Recommended No action is required. Action Severity INFO CNM-3008 Message , [CNM-3008 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 191
is required. Action Severity INFO CNM-3012 Message , [CNM-3012], ,, INFO, , Deleteing an EG with luns setup for encryption can lead to luns being disabled if Encryption Group name is not preserved (). Probable Cause Indicates that the Encryption - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 192
16 CNM-3012 116 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 193
the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is is the description of the classes of configuration parameters that were uploaded. If AD is not permitted . Probable Cause Indicates a configDownload - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 194
causes. Recommended Check the error log, correct the error and rerun the configupload command. Action Severity INFO CONF-1022 Message , [CONF-1022], ,, WARNING, , Downloading configuration without disabling the switch was unsuccessful. Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 195
applied. Recommended Action Use the configure command and various other commands to erase configuration parameters that are no longer required failed. Probable Cause Indicates a configDefault error has occurred. Recommended Correct the error and try again. Action Severity INFO Fabric - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 196
configRemove failed. Probable Cause Indicates a configRemove error has occurred. Recommended Correct the error and try again. Action Severity INFO CONF-1042 Message , [CONF-1042], ,, INFO, , Fabric Configuration Parameter changed to - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 197
Chapter CTAP System Messages 18 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 198
18 CTAP-1001 122 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 199
, Initiator: , LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed. The operation has been started, completed or cancelled. Recommended No action is required. Action Severity INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 200
is disabled. Recommended No action is required. Action Severity WARNING CVLC-1007 Message Probable Cause , [CVLC-1007], ,, ERROR, , Removal of encryption LUN is not allowed when decrypt of existing data is enabled.\nContainer: - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 201
No action is required. Action Severity ERROR CVLC-1010 Message , [CVLC-1010], ,, ERROR, , Tape license is required for tape container: . Probable Cause Indicates that the tape container is configured with non-Brocade mode but there - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 202
found in the metadata. Recommended No action is required. Action Severity ERROR CVLC-1014 Message Probable Cause , [CVLC-1014], ,, ERROR, , Missing Key ID from user input.\nContainer: , Initiator: , LUN ID - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 203
Probable Cause Indicates that the LUN is set as read-only because there is a conflict in the configuration. Recommended No action is required. Action LUN ID: . Probable Cause Indicates a warning or an error event. Recommended No action is required. Action Severity INFO CVLC-1018 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 204
exists on the LUN that is clear text. Recommended Use cryptocfg command to confirm the configuration. Action Severity ERROR CVLC-1021 Message , [CVLC-1021], ,, INFO, , User provided key ID is ignored while metadata - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 205
action is required. Action Severity INFO CVLC-1025 Message , [CVLC-1025], ,, ERROR, , Secondary Metadata exists for encrypted LUN not configured with -newLUN option .\nContainer: , Initiator: , LUN ID: - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 206
, [CVLC-1027], ,, ERROR, , Encrypted LUN configured with -newLUN option does not contain any . Probable Cause Indicates a warning event. Recommended Perform a manual rekey on this LUN. Action Severity WARNING CVLC-1029 Message Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 207
container name>, Initiator: , LUN ID: . Probable Cause Indicates the manual rekey was completed on primary LUN. Recommended Action 1. Make the target ports of the mirror LUN offline to hosts. 2. Re-establish the mirror. 3. Once the mirror is in sync, split the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 208
reason>. Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation failed. Recommended No action is required. Action Severity INFO CVLC-1035 Message , [CVLC-1035], ,, ERROR, , A decommissioned LUN has been added back as - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 209
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CVLM-1003 Message , [CVLM-1003], ,, INFO, , Crypto device configuration - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 210
the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch. Probable Cause Indicates that Crypto service is enabled or disabled on - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 211
address of EE IO link is not configured. Probable Cause Indicates that the EE IO link IP address is not configured. Recommended Configure the EE IO link IP address. Action Severity WARNING CVLM-1011 Message , [CVLM-1011], ,, INFO, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 212
[CVLM-3001], ,, INFO, , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates the failback mode was set. Recommended No action is required. Action Severity INFO CVLM-3002 Message , [CVLM-3002], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 213
20 CVLM-3005 Recommended No action is required. Action Severity INFO CVLM-3005 Message , [CVLM-3005], ,, INFO, , Event: cryptocfg Status: success, Info: Cluster member removed from HA cluster . Probable Cause Indicates an HA cluster member - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 214
[CVLM-3009], ,, INFO, , Event: cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an encryption engine. Recommended No action is required - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 215
20 CVLM-3013 Probable Cause Indicates an initiator was removed from a cryptotarget container. Recommended No action is required. Action Severity INFO CVLM-3013 Message , [CVLM-3013], ,, INFO, , Event: cryptocfg Status: success, Info: LUN , - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 216
20 CVLM-3016 CVLM-3016 Message , [CVLM-3016], ,, INFO, , Event: cryptocfg Status: success, Info: Lun , attached through Initiator \\, in crypto target container \\ enabled. Probable Cause Indicates a LUN in a - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 217
Message , [CVLM-3021], ,, INFO, , Event: cryptocfg Status: success, Info: Manual rekey all performed. Probable Cause Indicates a complete manual rekey was performed. Recommended No action is required. Action Severity INFO CVLM-3022 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 218
20 CVLM-3024 CVLM-3024 Message , [CVLM-3024], ,, INFO, , Event: cryptocfg Status: success, Info: Transaction aborted. Probable Cause Indicates a transaction abort operation was performed. Recommended No action is required. Action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 219
, [CVLM-3028], ,, INFO, , Event: cryptocfg Status: success, Info: SRDF mode set to . Probable Cause Indicates that the SRDF mode was set. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 143 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 220
20 CVLM-3028 144 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 221
Chapter DAUTH System Messages 21 DOT1-1001 Message , [DOT1-1001], ,, INFO, 802.1X is enabled globally. Probable Cause Indicates that the 802.1X is enabled globally. Recommended No action is required. Action Severity INFO DOT1-1002 Message , [DOT1-1002], < - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 222
failed on port . Probable Cause Indicates that the authentication has failed on a particular port. Recommended Check the credentials configured with Supplicant and the RADIUS server. Action Severity WARNING DOT1-1007 Message , [DOT1-1007], ,, CRITICAL, No - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 223
required. Action Severity INFO DOT1-1010 Message , [DOT1-1010], ,, INFO, Port is set in auto mode. Probable Cause Indicates that the port is set to auto mode. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 147 53 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 224
21 DOT1-1010 148 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 225
to the console. Recommended Action Verify that the location temperature is within the operational range of the switch. Refer to the Hardware Reference Manual for the environmental temperature range of your switch. Run the fanShow command to verify that all fans are running at normal speeds. If any - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 226
Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root access is environment and make sure the room temperature is within the operational range of the switch. Use the fanShow command to verify fans are operating properly. Make sure there - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 227
switch has exceeded environmental limits. A reset is sent to the faulty slot or the switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch the logical switch configuration, change the configuration with the lscfg - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 228
to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades. Severity CRITICAL EM-1010 not. Recommended Try reseating the blade. If this fails to correct the error, replace the blade. Action Severity CRITICAL EM-1012 Message , [ - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 229
switch does not have hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference Manual for more information on this command. If the message persists, replace the FRU. Severity CRITICAL EM-1013 Message , [EM-1013], ,, ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 230
that a problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 231
chassisConfig option is not supported by the firmware on the standby control processor switch (for nonbladed switches). Severity WARNING EM-1029 Message , [EM-1029], ,, WARNING, , , a problem occurred accessing a device on the I2C bus ( - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 232
for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in set to faulty because CP ERROR asserted Probable Cause Indicates that the standby - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 233
22 EM-1035 EM-1035 Message , [EM-1035], ,, ERROR, , 2 circuit paired Power Supplies are faulty, please check the AC main switch/circuit to see if it has power. Fabric OS Message Reference 157 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 234
wide name (WWN) card, then default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU card. If the message persists, reboot or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. To run this command root - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 235
can display: • voltages in volts • temperature in Celsius • fan speeds in RPM Recommended If the message is isolated, monitor the error messages on the switch. If the message is associated Action with other messages, follow the recommended action for those messages. Severity WARNING EM-1042 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 236
from the chassis. If the reason is due to backplane, the CP type (CP256) is not supported on that chassis (backplane revision D2), remove the blade from the chassis. If the reason is switch configuration, the blade's logical switch configuration is not correct. Run the lscfg command to correct the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 237
1033. The new standby CP is in the process of rebooting and has turned off the CP_ERR signal. Recommended No action is required. Action Severity INFO has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 238
the switch is being automatically reset because of a known resetable transient problem such as an application-specific integrated circuit (ASIC) parity error. Recommended Action No action is required if the switch does not reach the reset threshold for the switch or blade. If the reset threshold - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 239
Make sure the replacement is compatible with your switch type. Action Severity ERROR EM-1060 Message , [EM-1060], or run haSyncStart. Probable Cause Indicates a blade in the system is not supported by the release on the standby control processor (CP). Recommended Action Remove all - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 240
off because a hardware (HW) application specific integrated circuit (ASIC) ERROR was detected, and you have selected to power off the problem blade when such a condition occurred. Recommended Contact the switch provider for support. Action Severity CRITICAL EM-1065 Message , [EM-1065 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 241
or Storage Application Services (SAS) firmware has been configuration or hardware problems on the switch. Recommended Reboot or power cycle the switch. If the message persists, collect switch information using the Action supportsave command, and contact your switch service provider. Severity ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 242
to verify that the switch does not have hardware problems. To run this command root access is required. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the specified FRU; otherwise replace the switch. Severity ERROR 166 Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 243
traffic disruption. Recommended Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 244
domain id>. Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 245
. Recommended If the message persists, run the supportFtp command (as needed) to set up automatic FTP Action transfers; then run the supportSave command and contact your switch service provider. Severity ERROR ESW-1002 Message , [ESW-1002], ,, INFO, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 246
that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV) functionality, but the switch has some NPIV devices logged into the fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDOwnload Action command. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 247
Cause Indicates that the blade has area swapped ports on ports that do not support this feature. Recommended Replace the blade with ports that support port swap. Refer to the Fabric OS Administrator's Guide Action for more information. Severity WARNING Fabric OS Message Reference 171 53-1001767 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 248
24 ESW-1008 172 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 249
EVMD System Messages 25 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote proxy - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 250
25 EVMD-1001 174 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 251
that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent a payload with an invalid size. Recommended Action Investigate the neighbor switch for problems. Run the errShow command on the neighbor switch to view the error log for additional - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 252
frame. If it is due to problems with the kernel, the system will recover by performing a failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1005 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 253
, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1008 Message , [FABR-1008], ,, WARNING, , . Probable Cause Indicates that - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 254
is rare and usually indicates a problem with the Fabric OS. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR FABR-1012 Message , [FABR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 255
. A '0' means the IDID mode is disabled; a '1' means it is enabled. Set the switch to insistent domain ID mode. This mode is set under the configure command or in Web Tools on the Switch Admin > Configure window. Severity ERROR FABR-1015 Message , [FABR-1015], , FFDC - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 256
disabled on the switch through a user interface command. set the principal switch using the fabricPrincipal command. The message notifies you that the switch failed to become the principal switch because of one of the following reasons: • The switch exceeds supported configuration ( - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 257
licensed limit. Contact your switch provider to obtain a full fabric license. Severity CRITICAL FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 258
switch provider to obtain a full fabric license. Severity CRITICAL FABR-1023 Message , [FABR-1023], ,, INFO, , Fabric size is within supported configuration has exceeded the limit set by your value-line switches. Value-line switches have a limited fabric - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 259
the buffer credits are fixed, based on the port configuration information. In this mode, the buffer credits are negotiated the maximum number of retries sending internal link service (ILS) to the iswitchd demon on the number>, WARNING, , Remote switch with domain ID and - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 260
Area. You must manually enable the port or the port remains disabled forever. Refer to the Admin Guide for more information is being disabled because when the port on a Switch is Trunk Area enabled, it does not allow >, INFO, , Port configuration incompatible with Trunk Area enabled port. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 261
the port attempts to go online, the Switch finds that Trunk Area enabled is incompatible with port configuration such as long distance, port mirror, WARNING, , Invalid domain id zero received from principal switch (domain id=). Probable Cause Indicates an invalid - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 262
persists, run the supportFtp command (as needed) to set up automatic FTP transfers followed by the supportSave command and contact your switch service provider. Severity ERROR FABR-1043 Message , [FABR-1043], , ERROR, , Detected Fabric ID conflict with - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 263
. But no ports are disabled because the remote switch is not adjacent to the local switch. Recommended Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to Action a VF-capable firmware. Severity ERROR Fabric OS Message Reference 187 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 264
inherited FID of the local switch. All E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to Action a VF-capable firmware. Severity ERROR 188 Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 265
by the software. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 266
state to blade driver Recommended Action If the message is isolated, monitor the error messages on the switch. If the error is repetitive or if the fabric failed, fail over or reboot the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 267
unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message Probable Cause , [FABS-1011 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 268
to the requested state. This is usually an internal Fabric OS problem. Recommended Action Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR FABS-1013 Message , [FABS-1013], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 269
. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message Reference 193 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 270
27 FABS-1015 194 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 271
disruptive firmwareDownload is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP blade. If required, send the AP blade back to the factory to get a new firmware version installed. Severity ERROR Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 272
28 FBC-1001 196 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 273
is low on memory and failed to allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 274
29 FCMC-1001 198 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 275
or switch. Recommended Retry the command. Action Severity CRITICAL FCIP-1002 Message , [FCIP-1002], , INFO, CFG, , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 276
policy was deleted and the config file was updated. Recommended No action is required. Action Severity INFO FCIP-1004 Message , [FCIP-1004], , INFO, CFG, , Tape Read Pipelining is being disabled slot () port () tunnel ( - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 277
, , calloc failed for . Probable Cause Indicates a memory failure. Recommended Check the switch memory status. Action Severity ERROR FCOE-1002 Message , [FCOE-1002], ,, WARNING, , Max login Group limit reached at . Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 278
. Probable Cause Indicates that the IfIndex Limit has reached the maximum. Recommended Check the IfIndex Limit. Action Severity ERROR FCOE-1008 Message Probable Cause , [FCOE-1008], ,, INFO, , Free RASLOG fill this later. Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 279
Remove unwanted N_port mappings and try adding N_port mapping. Action Severity INFO FCOE-1010 Message , [FCOE-1010], ,, ERROR, , Cleanup of login failed for port:. Probable Cause Indicates an invalid port number. Recommended Use the supportsave - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 280
request to a VLAN has failed. Recommended Rerequest to add ports to a VLAN. Action Severity ERROR FCOE-1015 Message , [FCOE-1015], ,, ERROR, , Request to add MACs to L2 for ifindex 0xx failed, rc:. Probable Cause Indicates an add request - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 281
for slot or port has failed. Recommended Rerequest to add MACs from L2 for slot/port. Action Severity ERROR FCOE-1019 Message , [FCOE-1019], ,, WARNING, , FLOGI ignored as FC-MAP not configured on FCOE VLAN. Probable Cause Indicates FC-MAP has not - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 282
has reached its maximum allowed FCoE device limit. Recommended Do not add any more FCoE devices to the switch. Action Severity WARNING FCOE-1023 Message , [FCOE-1023], ,, WARNING, , Too many logins on FCoE controller, max allowed = - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 283
's that was received on the switch does not match the original FLOGI. Recommended It is due to a CNA/target driver issue. No action is required. : WWN will be printed. Recommended Change the FCoE login group policy on the switch for the device to login. Action Severity ERROR FCOE-1029 Message < - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 284
31 FCOE-1030 Probable Cause Indicates a version mismatch between the FLOGI and the FDISCs. Recommended No action is required. Action Severity WARNING FCOE-1030 Message , [FCOE-1030], ,, WARNING, , Version mismatch between FIP LOGO and root VN port. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 285
priority pri_in> for which PFC / FCoE is disabled. Probable Cause Indicates the priority PFC/FCoE is not enabled. Recommended Configure as required. Action Severity WARNING FCOE-1035 Message , [FCOE-1035], ,, INFO, , Virtual FCoE port - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 286
31 FCOE-1036 210 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 287
a defect. Action Check with the device vendor for a firmware upgrade containing a defect fix. Severity WARNING FCPD-1002 Message error string> which is possibly a private device which is not supported in this port type Probable Cause Indicates that private devices will not respond to the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 288
32 FCPD-1003 212 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 289
that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The switch requires authentication when device authentication policy is set to ON. Probable Cause Indicates a device which does not support authentication has tried to log in to the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 290
33 FCPH-1002 214 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 291
No action is required. Action Severity INFO FCR-1004 Message Probable Cause , [FCR-1004], ,, INFO, , FC router physical devices offline at port . Indicates that one or more physical devices connected to the specified port have gone - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 292
Action Verify that the devices were intended to be taken offline. If not, verify that the devices are functioning properly. zone deleted at port . Probable Cause Indicates that a logical storage area network (LSAN) zone attached to the specified port was deleted from the edge fabric. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 293
logical storage area network (LSAN) zone was enabled in the edge fabric attached to the specified port. The enabled LSAN zone configuration is listed. Remote LSAN zone updated in domain . Probable Cause Indicates that a logical storage area network (LSAN) zone update was received from - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 294
(hex)>) fabric ID . Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended No action is required. Action Severity INFO 218 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 295
ERROR, , FC router proxy device entries exhausted on port . Probable Cause Indicates that the number of proxy devices is greater than allowed by the port resource. Recommended Action Remove excess logical storage area network resource problem. LSAN devices offline. For - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 296
the proxy device slots by using the fcrProxyConfig command or limit proxy devices by Action removing logical storage area network (LSAN) zone entries. Severity ERROR FCR-1023 Message , [FCR-1023], ,, WARNING, , Local phantom port WWN entries exhausted - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 297
Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic changes to EX_Port connectivity. WWN conflicts - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 298
Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic changes to EX_Port connectivity. WWN conflicts - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 299
number>,, INFO, , Physical device went offline in fabric . Probable Cause Indicates that the physical device > in fabric . Probable Cause Indicates that Secure mode was turned on in the edge fabric. Recommended No action is required. Action Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 300
zone name> enabled in the backbone fabric. Probable Cause Indicates that the specified logical storage area network (LSAN) zone was enabled in the backbone fabric. The enabled LSAN zone configuration is listed. Recommended No action is required. Action Severity INFO FCR-1037 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 301
of cfg/zone/alias entries created in a local fabric is greater than the local switch&apos zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones created is within the range of the local database limitations - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 302
area network (LSAN set. Recommended Action Setting port credits failed. Execute the portEnable command. If the problem persists try restarting the switch. If the message persists, collect switch information using the supportShow command, and contact your switch service provider. Severity ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 303
disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [ configuration parameter. Recommended Use the specified disable reason to identify a possible configuration parameter mismatch between Action the EX_Port and the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 304
the switch with Action one that supports backbone to edge routing. Severity INFO FCR-1057 Message , [FCR-1057], ,, ERROR, , EX_Port() incompatible long distance parameters on link. Probable Cause Indicates that the port, which is configured - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 305
an incompatible configuration setting. Probable Cause Indicates that virtual channel (VC) Link Init is enabled on the local switch and the remote switch is negotiating name>, Port disabled, system only supports EX/VEX_ports. Fabric OS Message Reference 229 53-1001767- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 306
Indicates that the maximum number of supported EX_ports or VEX_ports was exceeded. ERROR FCR-1065 Message , [FCR-1065], ,, ERROR, , Fabric on port was assigned two different fabric IDs. Probable Cause Indicates that another port on the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 307
disabled. This is caused by fosConfig --disable fcr, configDefault, or a configDownload with the fcrState set to 2 (disabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO FCR-1069 Message , [FCR-1069], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 308
enabled). Note that the FC Routing service is disabled by the factory. Recommended No action is required. Action Severity INFO FCR-1070 Message , [FCR-1070], ,, INFO, , The FC Routing configuration is set to default. Probable Cause Indicates that the FC - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 309
Probable Cause Indicates that the remote control processor (CP) has older firmware, which only supports a lower number of logical storage area network (LSAN) zones. This is causing the loss of the high-availability (HA) sync. Recommended Keep the number of LSAN Zones to the lower limit of the two - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 310
Make sure to remain within the maximum of supported front domains. Action Severity ERROR FCR-1077 Message , [FCR-1077], binding. The error is caused when the binding list details configured on the M-Model switch does not match with the currently configured front port domain - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 311
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected pause message. Recommended - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 312
disruption observed during the firmware download may have been due to this issue. Recommended No action is required. Action Severity WARNING FCR-1085 Message , [FCR-1085], ,, ERROR, , HA sync lost as remote CP does not support FCR based matrix. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 313
has the capability to use XISL. Recommended Disable the 'Allow to use XISL' mode of the domain by using the configure command. Action Severity ERROR FCR-1088 Message , [FCR-1088], ,, INFO, , LSAN tag added. Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 314
34 FCR-1092 Recommended No action is required. Action Severity INFO FCR-1092 Message , [FCR-1089], ,, ERROR, , FCR ELS trap entries exhausted. Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Collect supportsave data and - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 315
: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte hexidecimal value that represents the switch port of the switch that the FICON Channel is directly connected to. DD - Device Domain - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 316
or Disabled> RdBlkId . Probable Cause Indicates the configuration was changed manually. Recommended No action is required. Action Severity INFO FICN-1006 Message , [FICN-1006], ,, WARNING - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 317
Indicates a Selective Reset from the channel was received as either a normal part of path recovery or starting sequence in an error case. Recommended If there was a job failure associated with this event, please contact your vendor's customer support. Action Severity ERROR FICN-1008 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 318
Probable Cause Indicates the Control Unit/device presented a Read Record Set Sequence number different from the SDM's expected sequence number. event, please contact your vendor's customer Action support for assistance. Severity ERROR FICN-1013 Message Probable Cause Recommended Action < - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 319
LRC. This indicates data corruption between the emulation processing components. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1016 Message , [FICN-1016], ,, INFO, , DevIng:Received Logical Path - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 320
that cannot be associated with a FICON Control Unit CUADDR. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1019 Message , [FICN-1019], ,, ERROR, , DevTapeEgr:AS Link Level Reject (LRJ) from Chan on Path=0x - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 321
with this event, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1022 Message , [FICN-1022], ,, ERROR, , DevTapeEgr:FICON Selective Reset:Path= - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 322
the FICON tape write pipeline is completing an emulated Selective Reset sequence. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity INFO FICN-1027 Message Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 323
with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1029 Message , [FICN-1029], ,, ERROR, , HostDiskIng:FICON Selective Reset:Path= - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 324
DevicePort LPAR>. Probable Cause Indicates the FICON channel sent a System Reset to the disk control unit. Recommended No action is required. The MVS system was either set to IPL or performing error recovery. Action Severity WARNING FICN-1032 Message , [FICN-1032], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 325
side processing. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING, , HostIng:FICON System Reset received on Path= - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 326
that could not be associated with a FICON device. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1039 Message , [FICN-1039], ,, ERROR, , HostIng:FCUB Lookup failed for Path= - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 327
this device>. Probable Cause Indicates that protocol errors in emulation in the CU or network errors can cause a Selective Reset. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1044 Message , [FICN-1044 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 328
contact your vendor's customer support for assistance. Action Severity channel for this device> treating as system reset event. Probable Cause Indicates an LRJ from set to state=0x. Probable Cause Indicates there is an internal emulation error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 329
it no longer has an established path to its peer. Recommended This is an unexpected event; contact your vendor's customer support for assistance. Action Severity WARNING FICN-1050 Message , [FICN-1050], ,, WARNING, , ProcessEgrTirData:Lost Logical Path - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 330
to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN-1053], ,, INFO, , XRC Withdraw From Session: SessID - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 331
Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1058 Message , [FICN-1058], ,, ERROR, , Error return from frame generation processing for a FICON control unit: Path= - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 332
fast path hash table entry. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1062 Message , [FICN-1062], ,, ERROR, , Ingress Abort:Oxid=0x:Path - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 333
from a peer FC interface for an active emulation exchange. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1064 Message , [FICN-1064], ,, INFO, , Ingress Abort:Oxid=0x - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 334
event, please contact your vendor's Action customer support for assistance. Severity ERROR FICN-1069 Message Probable Cause , [FICN-1069], ,, ERROR, , Emulation Configuration Error on TunnelId . Indicates an error has been noted in the FICON - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 335
35 FICN-1070 Recommended If resolution of the configuration issue cannot be completed, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1070 Message , [FICN-1070], ,, INFO, , DevTapeIngr:Exceptional Status rcvd on Path=< - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 336
35 FICN-1073 FICN-1073 Message , [FICN-1073], ,, INFO, , HostTapeIngr:Unloaded:Path= :states=0x:cmds=0x - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 337
35 FICN-1076 Severity INFO FICN-1076 Message , [FICN-1076], ,, INFO, , HostTapeIngr:ReadCpReport:Path= :Emuls=0x - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 338
Last 4 commands received from the channel for this device> lastStatus=0x treating as system reset event. Indicates an LRJ from a FICON channel indicates that the channel does not have a path established to the CU. 262 Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 339
event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1085 Message , [FICN-1085], ,, INFO, , FICON FCIP Tunnel is Up on GE,tunnel Id=. Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 340
GE0 or GE1>,tunnel Id=. Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR 264 Fabric OS Message Reference 53 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 341
the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on these commands. Severity ERROR FICU-1003 Message , [FICU - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 342
control unit port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR FICU-1006 Message Probable Cause , [FICU-1006 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 343
problem. Recommended Action If the message persists, check the memory usage on the switch, using the memShow command. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 344
No action is required. Action Severity INFO FICU-1013 Message , [FICU-1013], ,, WARNING, , Host data file cannot be resetted to proper size. Probable Cause Indicates that the file system is too full to create a host data file of the proper size - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 345
36 FICU-1014 FICU-1014 Message , [FICU-1014], ,, INFO, , CUP SBTOV Timeout - %s, Type(%s). Probable Cause Indicates that the FICON Host failed to send an IU within the SBTOV. Recommended No Action is required. Action Severity INFO FICU-1015 Message < - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 346
FICU-1019 Message , [FICU-1019], ,, INFO, , Switch has been set offline by LP(%s). Probable Cause Indicates the Fibre Connectivity (FICON) Management server has disabled switch. Recommended No action is required. Action Severity INFO FICU-1020 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 347
36 FICU-1022 FICU-1022 Message , [FICU-1022], ,, ERROR, , Detected FC8-48 and/or FC8-64 that are not manageable in Virtual Fabric disabled chassis. Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 271 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 348
36 FICU-1022 272 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 349
WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 350
37 FKLB-1001 274 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 351
Cause Indicates that the LSU size exceeds what the system can support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. Severity ERROR FLOD-1005 Message , [FLOD-1005], ,, WARNING, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 352
38 FLOD-1006 Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required because the LSR is discarded. Action Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 353
Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is required. Action Severity ERROR FSPF-1002 Message , [FSPF-1002], ,, INFO, , Wrong neighbor ID () in Hello - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 354
identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID. It should be set to 0 for a non-hierarchical fabric. Brocade switches support only section ID 0. Recommended Action Use a frame analyzer to verify that - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 355
Recommended No action is required. Action Severity INFO 39 FSPF-1008 Fabric OS Message Reference 279 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 356
39 FSPF-1008 280 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 357
Cause Indicates that the Fabric OS state synchronization (FSS) service has dropped the update because an application has not set the transaction flag correctly. Recommended Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed Action system. Fabric OS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 358
is a nonbladed system. If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], , SLOT cp-slot-number | CHASSIS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 359
eth1 (as root) or run supportShow/supportSave to validate the network configuration; then try to restore the synchronization by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL FSS-1008 Message , [FSS-1008], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 360
40 FSS-1011 FSS-1011 Message , [FSS-1011], , SLOT cp-slot-number | CHASSIS, INFO, , FSS Info: . Probable Cause Indicates an informational message only. Recommended No action is required. Action Severity INFO 284 Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 361
the Fabric OS Command Reference Manual. Recommended No action is was logged as a result of a user-initiated action (such as running the problem. If the problem persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 362
fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade or downgrade was invoked. The new firmware version is not compatiable with the current running version. This causes a disruptive firmware upgrade or downgrade. Recommended For a dual CP system - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 363
particular policy of the end-user installation. Typically, low temperatures means that the fans and airflow of a switch are functioning normally. Verify that range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING FW - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 364
Indicates that the internal temperature of the switch has changed from a value outside of the particular policy of the Action end-user installation. Severity INFO FW-1009 Message < supply. If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 365
42 FW-1012 Recommended Set the high boundary above the normal operation range. Action Severity INFO FW-1012 . Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1033 Message , [FW-1033], ,, INFO, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 366
Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The receive performance area measures the amount of incoming laser to help you determine if the SFP is in good working condition or not. If the counter often exceeds the threshold, the SFP is deteriorating - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 367
within the acceptable range. The receive performance area measures the amount of incoming laser to help you determine if the SFP is in good working condition or as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1041 Message , [FW-1041], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 368
Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed. The transmit performance area measures the amount of outgoing laser to help you determine if the SFP is in good working condition or not. If the counter often exceeds the threshold, the SFP is deteriorating - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 369
within the acceptable range. The transmit performance area measures the amount of outgoing laser to help you determine if the SFP is in good working condition or as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1045 Message , [FW-1045], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 370
Value> . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low boundary. Recommended Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0 Action (Out_of_Range). If continuous or repeated - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 371
particular policy of the Action end-user installation. Severity INFO FW-1113 Message errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 372
by transient errors. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Check • two switches with the same domain ID have connected to one another. • two fabrics have joined. • an E_Port has gone offline. • a - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 373
• Two switches with the same domain ID have connected to one another. • Two fabrics have joined. • An E_Port has gone offline. • . An inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting. Severity INFO FW-1120 Message Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 374
Two switches with the same domain ID have connected to one another. • Two fabrics have joined. • An E_Port has gone offline. • A principal link has segmented from the fabric. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 375
of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1125 Message , [FW-1125 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 376
errors means that the fabric is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user . • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 377
of zone changes has fallen below the low boundary. Zone changes occur when there is a change to the effective zone configuration. A low number of zone configuration changes means that the fabric is functioning normally. Recommended No action is required. Respond to this message as is appropriate - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 378
or FLOGI. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1134 Message , [FW-1134], ,, INFO, , , is below low boundary(High= - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 379
or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1139 Message , [FW-1139], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 380
to the particular policy of the Action end-user installation. Severity INFO FW-1140 Message , problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 381
loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 382
continue to experience synchronization loss errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW- particular policy of the end-user installation. A low number of synchronization losses means that the switch is functioning normally. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 383
. Loss of signal generally indicates a physical problem. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. A low number of signal loss errors means that the switch is functioning normally. Severity INFO FW - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 384
to the particular policy of the end-user installation. Frequent loss of signal generally indicates a physical problem. Check both ends of your cable errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 385
occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1176 Message , [FW-1176], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 386
a hardware problem with an small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 387
to the particular policy of the end-user installation. Frequent fluctuations in CRC errors generally indicate an aging fabric. Check your the particular policy of the Action end-user installation. A low number of invalid CRCs means that the switch is functioning normally. Severity INFO FW- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 388
Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Frequent fluctuations in CRC errors generally indicate an aging fabric. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 389
has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1189 Message , [FW-1189], ,, INFO, , , , is below low boundary(High - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 390
for one of the following reasons: the port has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 391
changed for one of the following reasons: the port has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, that the number of link resets that the port experiences has changed. Link resets occur due to link timeout errors that indicate no frame activity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 392
low boundary. Link resets occur due to link timeout errors that indicate no frame activity at all. Recommended Respond to this message as is appropriate to the particular policy of the end-user installation. A low Action number of link resets means that the switch is functioning normally. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 393
. Recommended Respond to this message as it is appropriate to the particular policy of the end-user installation. A Action low number of C3 discard means that the switch is functioning normally. Severity INFO FW-1202 Message , [FW-1202], ,, WARNING, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 394
42 FW-1204 FW-1204 Message , [FW-1204], ,, INFO, , , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the trunk utilization has changed. Recommended No action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 395
Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch receives has changed. Receive performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended No action is required. Respond to this message as - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 396
Probable Cause Indicates that the number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair. Recommended No action is required. Respond to this message as - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 397
The port has received small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 398
that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 399
that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 400
are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 401
. Probable Cause Indicates that the number of simple network management protocol read (RSNMP) violations has changed. RSNMP IP address. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 402
done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO 326 Fabric OS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 403
through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1339 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 404
for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI command to determine the IP location of the login attempt. Responses to security-class messages depend on user policies. Consult your - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 405
downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps track - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 406
FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This counter keeps - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 407
switch. This counter keeps track of the number of packets received with invalid certificates. Recommended Responses to security-class messages depend on user failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 408
not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number of authentication failures. Recommended Responses to security-class messages depend on user policies - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 409
value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 410
fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 411
fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 412
is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security database means that the version stamp and fabric configuration server (FCS) policy matches exactly. Recommended No action is required. Action Severity INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 413
. This counter tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch as well as one security command that can be executed only on - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 414
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1401 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 415
slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended You might have to remove message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1404 Message , [FW-1404], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 416
Severity INFO FW-1424 Message Probable Cause , [FW-1424], ,, WARNING, , Switch status changed from to . Indicates that the switch status is not in a healthy state. This occurred because of a policy violation. 340 Fabric OS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 417
the Action end-user installation. Severity INFO FW-1426 Message , [FW-1426], ,, WARNING, , Switch status change switch status is not in a healthy state. This occurred because the number of faulty power supplies is greater than or equal to the policy set - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 418
change contributing factor Fan: bad. Indicates that the switch status is not in a healthy state. This occurred because the number of faulty fans is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is faulty when sensor value is not in the acceptable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 419
the number of faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs are non-redundant. If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the micro-switch of the active CP before the heartbeat is up, this will cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 420
contributing factor Flash: usage out of range. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the flash usage is out of range. The policy was set using the switchStatusPolicySet command. Recommended Run the supportSave command to clear out the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 421
[FW-1439], ,, WARNING, , Switch status change contributing factor Switch offline. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the switch is offline. Recommended Run the switchEnable command. Action Severity WARNING - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 422
that more than one power supply may be required to provide adequate power. So (even if the AP blade is powered down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to maintain full (2X) redundancy. 346 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 423
for full (2X) redundancy, but the user has previously overridden the Switch Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch status is DOWN, 0 indicates no - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 424
loss of signal and fails. Both physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Recommended No action is required. Respond to this - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 425
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot to the particular policy of the Action end-user installation. Severity INFO FW-1515 Message , - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 426
occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1518 Message , [FW-1518], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 427
occur due to software glitches. Persistent protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1519 Message , [FW-1519], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 428
Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Frequent fluctuations in CRC errors generally indicate an aging fabric. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 429
as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1527 Message , [FW-1527], has changed for one of the following reasons: the port has gone offline, has come online, is testing, is faulty, has become an E_Port, has become an F_Port, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 430
has gone offline, has come online, is testing, is resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Respond to this message as is appropriate to the particular policy of the end-user - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 431
42 FW-1532 Recommended Check the target device. It could be slow. Action Severity INFO FW-1532 Message , [FW-1532], ,, INFO, , , , has dropped below upper threshold boundary to in between(High=, Low=). Current - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 432
Disabling port fencing feature for this. Probable Cause Indicates that in previous versions portfencing is configured for Link/Sync loss, but after upgrading to new version, in which portfencing is not suppoted, resets the above bit. Recommended No action is required. You are informed that PF bit - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 433
loss that the circuit experiences has changed. Recommended Respond to this message as it is appropriate to the particular policy of the end-user installation. Action Severity INFO FW-3015 Message , [FW-3015], ,, INFO, , , is below low - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 434
has changed for either of the reason that if the circuit has gone offline or it has come online. Recommended Respond to this message as is appropriate to the particular policy of the end-user installation. Action Severity INFO FW-3019 Message , [FW-3019], ,, INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 435
above the high boundary. The state of the circuit has changed for the reason that the circuit has gone offline, it has come online, or it is testing. Recommended No action is required. Action Severity WARNING FW-3021 Message , [FW-3021], ,, WARNING, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 436
42 FW-3021 360 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 437
it. If the problem persists, replace Action the standby CP. Run the supportSave command and contact your switch service provider. Severity CRITICAL the system has been rebooted either because of a user action or an error. The switch reboot can be initiated by the firmwareDownload, fastBoot, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 438
• Fastboot:SNMP • Reboot • Chassis Config • Reboot:API • Reboot:HAM • EMFault:EM Recommended Check the error log on both CPs for additional messages down. The active CP will run a diagnostic test on the EMAC controller and will wait for the standby CP to reset it if it is down. Recommended No action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 439
reset the active CP. The system will be non-redundant as the standby becomes the active CP. Run the supportSave command and contact your switch service at certain stage or cold/warm recovery failed. If auto-reboot is disabled, the system needs to be manually rebooted for recovery. This follows if - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 440
when system is not ready for warm recovery. Recommended Manually trigger reboot for cold recovery if needed, or wait until system is ready CHASSIS, CRITICAL, ,Password database conversion failed. Probable Cause Indicates the password database conversion failed. Recommended No action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 441
-number | CHASSIS, CRITICAL, . Probable Cause Indicates a software watchdog detected termination of a restartable daemon and needed to reboot/failover. Recommended If needed manually initiate a reboot/failover. Action Severity CRITICAL Fabric OS Message Reference 365 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 442
43 HAM-1014 366 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 443
switch reboot automatically and attempts a cold recovery. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service command, the standby CP blade being reset or removed, of an error in the standby CP blade. Recommended - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 444
of heartbeat. This message is typically seen when the standby CP has been rebooted. Note that in certain circumstances a CP may experience a double reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice. Recommended No action is required. Action Severity INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 445
blade or switch (for nonbladed switches). Action Severity ERROR HIL-1102 Message , [HIL-1102], ,, ERROR, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 446
that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR HIL-1105 Message , [HIL-1105], ,, ERROR, , Switch error, () above threshold. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 447
and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. Fabric OS Message Reference 371 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 448
that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the fan continues to generate this message, replace - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 449
threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is switch. Refer to the hardware reference manual for your switch for the operational temperature range. Use the fanShow command to monitor the status of the fan generating this error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 450
a fan field-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 Message , [HIL-1302 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 451
Replace the faulty fan FRUs immediately. Action Severity ERROR HIL-1307 Message , [HIL-1307], ,, ERROR, , Four or five fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 452
WARNING, , fans faulty. Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 453
45 HIL-1402 Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed. Recommended Install the missing fan FRU. Action Severity WARNING HIL-1402 Message , [HIL-1402], ,, WARNING, , Two fan FRUs missing. Install fan FRUs - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 454
sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. Severity CRITICAL HIL-1503 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 455
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 456
Action To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 457
any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. Severity ERROR HIL-1602 Message , [HIL-1602], , FFDC, CRITICAL, , Multiple temperature sensors failed. Service immediately. Probable Cause Indicates that temperature - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 458
source and then switch on Action the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL-1650 Message , [HIL-1650], , ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 459
In the Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended Action The dead timeout value of the remote switch must be compatible with the value specified in the FSPF protocol - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 460
the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in the FSPF Action protocol. Refer to - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 461
Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 385 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 462
47 HMON-1001 386 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 463
is required. Action Severity CRITICAL HSL-1001 Message , [HSL-1001], ,, CRITICAL, , Failed to acquire system mac address pool. Probable Cause Indicates the failure to acquire a system address. Recommended No action is required. Action Severity CRITICAL - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 464
inserted. Recommended Use the correct SFP for this interface. Action Severity ERROR HSL-1005 Message , [HSL-1005], ,, 1006], ,, CRITICAL, , Failed to get kernel page size bytes for mmap. Indicates that there is not enough - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 465
48 HSL-1007 Recommended Install more memory on board. Action Severity CRITICAL HSL-1007 Message , [HSL-1007], ,, ERROR, , Failed to read SFP for interface . Probable Cause Indicates a failure to read an SFP. Recommended No action is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 466
48 HSL-1007 390 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 467
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that initiated by User: , Role: could not be completed successfully - . Probable Cause Indicates an error in completing - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 468
49 HTTP-1003 392 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 469
Chapter IBD System Messages 50 IBD-1001 Message , [IBD-1001], ,, ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 470
50 IBD-1001 394 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 471
Initiator name>] Probable Cause Indicates that the initiator name length exceeds the supported limit of characters. Recommended Change the initiator name, keeping the number of characters within the supported limit. Action Severity WARNING IBPD-1002 Message , [IBPD-1002], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 472
51 IBPD-1003 396 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 473
the iSCSI configuration has been committed by a remote switch in the fabric. Recommended No action is required. Action Severity INFO ICPD-1004 Message Probable Cause , [ICPD-1004], ,, WARNING, , iSNS Client service is detected on multiple switches in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 474
Client service on a single switch in the fabric using the fosConfig command. Refer Action to the Fabric OS Command Reference for more information on this command. Severity WARNING ICPD-1005 Message , [ICPD-1005], ,, WARNING, , iSCSI configuration between - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 475
Recommended No action is required. Action Severity INFO 52 ICPD-1008 Fabric OS Message Reference 399 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 476
52 ICPD-1008 400 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 477
address change> . Probable Cause Indicates that a change in the gateway IP address has occurred. If the source of the address change is manual, this means that the address change was initiated by a user. If the source of the address change is the dynamic host - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 478
53 IPAD-1001 402 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 479
the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 480
that tunnel setup failed because of an authorization failure from the remote side. A reason for such a failure could be a WWN mismatch. Recommended Change the tunnel configuration on one side of the tunnel to authorize the remote side to set up Action the tunnel. Severity WARNING IPS-1006 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 481
Chapter ISCS System Messages 55 ISCS-1000 Message , [ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended No action is required; the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 482
55 ISCS-1000 406 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 483
, [ISNS-1001], ,, INFO, , Configuration peering with external iSNS server slot/port /ge (current /ge - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 484
system-name>, Peering with external iSNS server not started because configuration unchanged. Indicates that peering with the external internet storage name service (iSNS) server was already started with the same configuration. 408 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 485
configuration and retry the peering with the external Action iSNS server. Severity INFO ISNS-1009 Message , [ISNS-1009], ,, INFO, , Peering with external iSNS server - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 486
INFO, , Start peering with external iSNS server on management port. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) on the management port. Recommended No action is required. Action Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 487
with the primary or backup key vault. Recommended Determine whether the configured key vault is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1004 Message , [KAC-1004], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 488
put to the primary or backup key vault. Recommended Determine whether the configured key value is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1008 Message , [KAC-1008], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 489
. An abort signal is sent. Recommended Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD-1002], , FFDC, WARNING, , Detected termination of - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 490
58 KSWD-1002 414 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 491
open ATA dump device Probable Cause Indicates the ATA dump driver is not initialized properly. Recommended No action is required. Action Severity ERROR KTRC-1004 Message Probable Cause , [KTRC-1004], ,, ERROR, , Cannot write to ATA dump device Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 492
59 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 493
that the l2sys encountered with System Service Manager (SSM) message queue errors. Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1004 Message Probable Cause , [L2SS-1004], ,, ERROR, , FDB error: Error in creating AVL tree. Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 494
even after two hash changes on the chip. Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1006 Message , [L2SS-1006], ,, INFO, , Mac-address-table table on slot chip is 95 percent full. Probable Cause Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 495
initialization of a module within the LACP daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR Fabric OS Message Reference 419 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 496
61 LACP-1001 420 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 497
Chapter LANCE System Messages 62 LANCE-1000 Message , [LANCE-1000], ,, ERROR, , Slot Port GE : Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the port is disabled. Recommended - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 498
62 LANCE-1000 422 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 499
Manager service is enabled by the factory setting and it is not user configurable. Recommended No action is required. Action Severity INFO LFM-1003 Message , [LFM-1003], ,, INFO, , The Logical Fabric Manager configuration is set to default. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 500
>, error value . Probable Cause Indicates the trigger for some internal logging purpose. Recommended Send the ffdc log to the support. 1006], ,, WARNING, , The switch with domain with firmware version has joined the FID fabric - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 501
Action Run the reboot command for nonbladed switches or the haFailover command on bladed switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING LOG-1002 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 502
64 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 426 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 503
is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message , [LSDB-1002], ,, INFO, , Local Link State - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 504
for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended No action is required. The other switch will pass the LSD once the fabric is stable. Action Severity WARNING 428 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 505
needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], ,, INFO, , Chassis FRU header not programmed for switch NID, using defaults (applies only - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 506
purposes only, and no action is required. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure Tab > Fabric Subtab > Insistent Domain ID Mode check box. The switch must be disabled to change the IDID mode. Severity WARNING 430 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 507
lsrP, lsId = Probable Cause Indicates a link state record is null. Recommended No action is required. Action Severity ERROR MPTH-1003 Message , [MPTH-1003], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 508
67 MPTH-1003 432 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 509
• 12 - MSG_US • 13 - MSG_EXT_RSCN • 14 - MSG_RDTS_START • 15 - MSG_RDTS_SENDEFP • 16 - MSG_RDTS_RESET Recommended No action is required. Action Severity ERROR MQ-1005 Message , [MQ-1005], ,, WARNING, , queue : queue full (miss= - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 510
68 MQ-1006 MQ-1006 Message , [MQ-1006], ,, WARNING, , queue : msg too long (:) Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended No action is required. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 511
service is not set. • The GCAP (MS Get Capabilities) is not supported by another switch. • The request to the exchange platform database was rejected. The remote switch might be busy. The domain number is the target domain that caused the error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 512
command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS number is the target domain that caused error. Recommended Action The fabric might be set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 513
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], ,, ERROR, , MS Failure while initializing - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 514
problems such as bad cables or small form-factor pluggables (SFPs). It may be necessary to replace hardware if these messages persist. Severity ERROR needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR MS-1022 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 515
Service is being enabled or disabled. Recommended No action is required. Action Severity INFO MS-1024 Message , [MS-1024], ,, INFO, , Management Server Access Control List is Updated service is blocked. Recommended Enable Platform service on the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 516
69 MS-1026 440 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 517
, execute the haFailover command. If the problem persists or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR MSTP-2001 Message , [MSTP - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 518
70 MSTP-2002 Recommended No action is required Action Severity INFO MSTP-2002 Message , [MSTP-2002], ,, INFO, , . My Bridge ID: Old Root: New Root: Probable Cause Indicates that the MSTP - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 519
70 MSTP-2006 Recommended No action is required. Action Severity INFO MSTP-2006 Message , [MSTP-2006], ,, INFO, , MSTP instance brigde priority is changed from to . Probable Cause Indicates that the MSTP instance - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 520
70 MSTP-2006 444 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 521
- Down • 1 - Init • 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 522
ERROR NBFS-1003 Message , [NBFS-1003], ,, WARNING, , DB_XMIT_SET flag not set in state , input , port Probable Cause Indicates the database transmit set flag was not set from this problem. Action Severity WARNING - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 523
switch to the latest level of firmware. Action Severity WARNING NS-1003 Message , [NS-1003], ,, INFO, , Number of local devices , exceeds the standby can support , can't send update - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 524
of the lowest version of firmware. Severity INFO NS-1005 Message , [NS-1005], ,, WARNING, , Zone size of has over the supporting limit of for the remote switch domain ID . Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 525
. Routing may not be setup correctly. Probable Cause Indicates that a logical the routing may not be set up correctly. Action Severity to a licensed switch. Action Severity wwn as zero, DCFM wont show port connectivity. Recommended configured devices from QoS zone. Action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 526
Cause Indicates that a failover flag has disabled TI zone in a base switch fabric. Recommended Modify failover flag to enable or remove TI zone with failover flag disabled since the routing may not Action be setup correctly. Severity WARNING 450 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 527
Message , [NSM-1003], ,, INFO, , Interface is link down. Probable Cause Indicates that the interface is offline as the link is down. Recommended Check whether the connectivity is proper and the remote link is up. Action Severity INFO NSM - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 528
73 NSM-1005 Recommended No action is required. Action Severity INFO NSM-1005 Message , [NSM-1005], ,, INFO, ,The FCoE VLAN: is in use. First remove all the FCoE sessions of its member ports and then try again to disable it. Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 529
73 NSM-1009 Recommended No action is required. Action Severity INFO NSM-1009 Message , [NSM-1009], ,, INFO, , Interface is deleted. Probable Cause Indicates that the logical interface has been deleted. Recommended No action is required. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 530
73 NSM-1013 Recommended No action is required. Action Severity INFO NSM-1013 Message , [NSM-1013], ,, INFO, , Vlan classifier group is deleted. Probable Cause Indicates that Vlan classifier group has been deleted. Recommended No action is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 531
73 NSM-1017 Recommended No action is required. Action Severity INFO NSM-1017 Message , [NSM-1017], ,, INFO, , Interface is on interface . Probable Cause Indicates that logical interface member list has been - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 532
NSM-1022 Message , [NSM-1022], ,, WARNING, , . Probable Cause Indicates internal error information. Recommended To be transmitted to engineering for problem analysis. Action Severity WARNING 456 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 533
INFO ONMD-1002 Message , [ONMD-1002], ,, INFO, , LLDP global configuration is changed. Probable Cause Indicates that LLDP Global configuration has been changed. Recommended No action is required. Action Severity INFO ONMD-1003 Message Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 534
74 ONMD-1004 Recommended No action is required. Action Severity INFO ONMD-1004 Message , [ONMD-1004], ,, INFO, , LLDP is disabled on interface . Probable Cause Indicates that LLDP is disabled on interface. Recommended No action is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 535
configuration file during the installation. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 536
configuration file sync.conf contains too many entries. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 537
command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1009 Message , [PDM-1009], ,, WARNING, , Can't update Port Config Data. Probable Cause Indicates the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 538
: Probable Cause Indicates the switch configuration file /etc/fabos/fabos.[0|1].conf is empty. Recommended Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 539
firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service ,, WARNING, , Failed to download area port map. Fabric OS Message Reference 463 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 540
firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service domain name service (DNS) is configured for IPv6. IPv6 is not supported by older firmware. Recommended Configure DNS with IPv4 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 541
to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set means that the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved. Recommended Run the pdShow command to view the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 542
76 PDTR-1002 466 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 543
Error string> Probable Cause Indicates nonrecoverable PCI errors set up automatic FTP transfers; then run the supportSave command and contact your switch service certain circumstances a CP may experience a double reset and reboot twice in a row. A either because of an error condtion or being fenced - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 544
, Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected. Recommended The FRU must be replaced. Action Severity CRITICAL 468 Fabric OS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 545
INFO PMGR-1004 Message Probable Cause , [PMGR-1004], , WARNING, ,Attempt to create switch failed. Error message: . Indicates that the switch with the specified FID was not deleted. Fabric OS Message Reference 469 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 546
Action Severity INFO PMGR-1006 Message , [PMGR-1006], , WARNING, , Attempt to move port(s) on slot to switch failed. Error message: . Probable Cause Indicates the unsuccessful attempt to move the ports to the specified - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 547
[PMGR-1010], , WARNING, , Attempt to change the base switch to switch failed. Error message: . Probable Cause Indicates the failed attempt to change the base switch. Recommended No action is required. Action Severity WARNING PMGR-1011 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 548
78 PMGR-1011 472 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 549
on this port had multiple failures that exceeded an internally set threshold on the port. This problem is typically related to not support configured L_port. Issue portCfgLport to clear configuration. Indicates the specified port is configured to be an L_port, but the port does not support L_port. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 550
changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended No action is required. Action Severity INFO PORT-1007 Message , [PORT-1007], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 551
system-name>, Port (ID: ) QOS is disabled. Probable Cause The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS to be disabled on a 4G or 8G long distance platform. Recommended This is normal; no action required. Action Severity WARNING Fabric - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 552
79 PORT-1010 476 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 553
does not happen, restart Action or power cycle the switch to re-initiate the firmware. Severity CRITICAL PS-1001 Message , [PS-1001], ,, INFO, , Advanced Performance Monitoring configuration updated due to change in PID format Probable Cause Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 554
80 PS-1004 Probable Cause Indicates that the restoring configuration has failed to set the end-to-end monitoring mask on at least one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring can only be - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 555
80 PS-1007 PS-1007 Message , [PS-1007], ,, WARNING, , Failed to add fabricmode toptalker on domain=. . Probable Cause Indicates that FCR or McData mode is enabled on this particular fabric. Recommended Action No action required - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 556
80 PS-1007 480 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 557
Probable Cause Indicates that the portSwap feature has been enabled in the switch. Recommended No action is required. Action Severity INFO PSWP-1003 Indicates that the portSwap command feature has been disabled in the switch. Recommended No action is required. Action Severity INFO Fabric OS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 558
on configInit with error code in switch number . Probable Cause Indicates that the bladeSwap command has failed to access the configuration data. Recommended Retry the command. If the failure persists, contact your support representative. Action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 559
(as needed) to set up automatic FTP transfers and run the Action supportSave command then contact your switch service provider. Severity INFO RAS ' error detected. Probable Cause Indicates an internal software error. Recommended Run the supportSave command and contact your switch service provider - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 560
command and contact your switch service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support data file () automatically transferred to remote address ' '. Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 561
82 RAS-3001 Probable Cause Indicates that the configured classes of the audit feature have been changed. Recommended No action is required. Action Severity INFO RAS-3001 Message , [RAS-3001], , INFO, < - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 562
82 RAS-3004 Recommended No action is required. Action Severity INFO 486 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 563
and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS memory usage on the switch using the memShow command. Restart or power cycle the switch. Severity ERROR Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 564
in Fabric OS v2.6, v3.1 and later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , [RCS-1005], ,, INFO, , Phase , - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 565
83 RCS-1007 Severity INFO RCS-1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 566
83 RCS-1008 490 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 567
Indicates that a First time encryption/re-key/Write Metadata was not started. Recommended Correct the Cluster Ethernet link error and retry. Action Severity ERROR RKD-1003 Message , [RKD-1003], ,, CRITICAL, , - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 568
84 RKD-1004 RKD-1004 Message , [RKD-1004], ,, INFO, , Message: . Probable Cause Indicates the generic rekey message. Recommended No action is required. Action Severity INFO RKD-1005 Message , [RKD-1005], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 569
Chapter RMOND System Messages 85 RMON-1001 Message , [RMON-1001], ,, INFO, , RMON rising threshold alarm from SNMP OID . Probable Cause Indicates that the threshold level has exceeded for the sample type of RMON alarm. Recommended Check the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 570
85 RMON-1002 494 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 571
Error: client \"\" has bad credentials: Probable Cause Indicates an authentication error was reported. The specified client IP . Probable Cause Indicates the SSL certificate file configured on the switch could not be accessed because the root did - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 572
number>,, WARNING, , Permission denied accessing private key file. Secure RPCd is disabled. Probable Cause Indicates the private key file configured on the switch could not be accessed because the root did not have read-level access. Recommended Change the file system access level for - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 573
specified domain ID is online. Enable the switch with the specified domain ID. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 574
Run the dom command to verify that the specified domain ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity INFO 498 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 575
Chapter SAS System Messages 88 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st=< - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 576
88 SAS-1001 500 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 577
values for daemon name are listed below. For a complete listing, see the Introduction to this manual. • fabricd • asd • evmd • fcpd • webd • msd • nsd • psd (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 578
89 SCN-1001 502 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 579
persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1002 Message , [SEC-1002], ,, ERROR, , Security data fails: - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 580
if the updating counter fails. Recommended Action If the message is the result of a user command, retry the statistic command. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 581
reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the the switch through the Telnet connection. Action Severity INFO SEC-1010 Message Probable Cause , [SEC-1010], ,, ERROR, < - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 582
ERROR SEC-1016 Message , [SEC-1016], ,, INFO, , Security violation: Unauthorized host with IP address - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 583
>,, ERROR, , Invalid IP address () detected. Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 584
in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1031 Message , [SEC-1031], ,, WARNING, , Current security policy DB cannot be supported by standby. CPs will go - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 585
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 586
grouped as eight Action colon separated pairs. For example: 50:06:04:81:D6:F3:45:42. Severity ERROR SEC-1038 Message , [SEC-1038], ,, ERROR, , Invalid domain . Probable Cause Indicates an invalid domain ID was entered. Recommended Verify that - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 587
not within the minimum and maximum range. Recommended Use valid syntax when entering port ranges. Action Severity ERROR SEC-1044 Message , [SEC-1044], ,, ERROR, , Duplicate member in (). Fabric OS Message Reference 511 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 588
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. 512 Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 589
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 590
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 591
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 592
domains or domains more than the maximum number supported are specified. Recommended Enter the correct number of domains. Action Severity ERROR SEC-1063 Message , [SEC-1063], ,, ERROR, , Failed to reset statistics. Probable Cause Indicates that either the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 593
unknown reasons. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1073 Message , [SEC-1073], ,, ERROR, , No FCS policy in list - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 594
zone. Recommended Re-enable the current zone configuration for the change to take effect. Action Severity ERROR SEC-1077 Message , [SEC-1077], ,, ERROR, , Failed to activate new policy set on all switches. Probable Cause Indicates the policy could not - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 595
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 596
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 597
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 598
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 599
not be correctly updated for that specific switch. Severity ERROR SEC-1093 Message , [SEC-1093], ,, ERROR, , New FCS list must have at least one member in common with current FCS list. Probable Cause Indicates the new fabric configuration server (FCS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 600
the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR SEC-1098 Message , [SEC-1098], ,, ERROR, , No FCS list - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 601
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 602
switch failed to download a certificate, security database, or policies. This can happen when the switch Guide. Severity ERROR SEC-1105 Message , [SEC-1105], ,, ERROR, , Fail to disable secure mode on all switches. Probable Cause Indicates the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 603
be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity INFO SEC-1108 Message , [SEC-1108], ,, ERROR, , Fail to reset stamp on all switches. Probable Cause Indicates that - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 604
>,, ERROR, , FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Probable Cause Indicates that either a security policy download is attempted with an active policy that does not have the fabric configurations - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 605
>,, INFO, , Fail to set . Probable Cause Indicates the switch failed to save the data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Run the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 606
, [SEC-1122], ,, INFO, , Error code: , . Probable Cause Indicates that one of the switches in the fabric could not communicate with the primary fabric configuration server (FCS). Recommended Run the secFabricShow command to verify - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 607
Probable Cause Indicates the security database was successfully downloaded from the primary fabric configuration server (FCS). Recommended No action is required -name>, The Primary FCS has failed over to a new switch. Probable Cause Indicates an FCS failover operation was completed successfully. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 608
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that switch. This message might also be the result of an internal corruption or a hacker - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 609
download received from Primary FCS. Probable Cause Indicates that a non-primary fabric configuration server (FCS) switch received a security database download the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that switch. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 610
passwords support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the firmware. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 611
caused when the switch is short of memory. The status values can be either defined, active, or both. A negative value means that a policy set was failed by low memory or internal error. The status values can be either defined, active, or both. A negative value means that a policy set was failed by - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 612
(as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO SEC configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 613
of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 614
of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 615
SEC-1173 Message , [SEC-1173], ,, ERROR, , Lost contact with Primary FCS switch. Probable Cause Indicates the switch has lost contact with the primary fabric configuration server (FCS) switch in the secure fabric. This could be due to the primary FCS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 616
>, [SEC-1176], ,, ERROR, , Failed to generate new version stamp. Probable Cause Indicates the primary fabric configuration server (FCS) failed to generate a new version stamp due to the fabric not being stable. Recommended Verify all switches in the fabric are in time - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 617
, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1184 Message , [SEC-1184], ,, INFO, , configuration change, action , server ID - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 618
90 SEC-1186 Probable Cause Indicates the switch database was enabled or disabled as the secondary authentication, accounting, and authorization (AAA) mechanism when the Remote Authentication Dial-in User Service (RADIUS) / Lightweight Directory Access Protocol (LDAP) is the primary AAA mechanism - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 619
Severity INFO SEC-1190 Message , [SEC-1190], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause Indicates an SNMP security violation was reported. The specified unauthorized host - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 620
error message lists the violating IP address. Verify that this IP address is being used by a valid Action switch admin. Use the correct password configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 621
>,, WARNING, , Switch does not have all default account names. Probable Cause Indicates the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default admin and user account names on the switch that reported the warning and - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 622
manage the fabric through an API connection. If so, add the host IP address to the API policy of the fabric. If the host is not A management server command was forwarded from a non-primary fabric configuration server (FCS) switch. Recommended Action Check the MS policy and verify that the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 623
via TELNET/SSH/RSH. IP Addr: Probable Cause Indicates the IP address of the remote station set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING SEC-1251 Message , [SEC-1251], ,, ERROR - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 624
and contact your switch service provider. Severity ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Probable Cause Indicates the switch is set up with VC-encoded mode. Recommended Turn off VC - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 625
fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in to update the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 626
the remote authentication dial-in user service (RADIUS) configuration have failed to respond to a switch request within the specified time-out. Recommended Verify the switch has proper network connectivity to the specified remote authentication dial-in user Action service (RADIUS) servers, and the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 627
the passwdCfg --setDefault command on each switch in the fabric to set the password policies to the default value. Then verify with passwdCfg --show that password policies are set to the default values on all switches and retry the secModeEnable command. Severity ERROR SEC-1312 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 628
to fix this error. If the problem persists contact your switch service provider. Action Severity ERROR SEC-1315 Message , [SEC-1315], ,, ERROR, , command failed - dbs configured for rejection - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 629
policy with the local switch. Recommended Check the conflicting policy and make the new swithces and the local switch policies the same. Action ,, INFO, , updated dbs(s) Probable Cause Indicates the specified event has occurred. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 630
a domain not supporting an access control ERROR, , Failed secure mode enable command. Reason: . Probable Cause Indicates the security enable failed on the fabric because the switch has a conflicting configuration such as fabric wide consistency configuration or AD configuration - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 631
attempt to join the switch with the fabric. Severity ERROR SEC-1326 Message , [SEC-1326], ,, INFO, , Event: fddcfg --fabwideset, Status: success, Info: Fabric wide configuration set to . Probable Cause Indicates the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 632
Probable Cause Indicates the IP filter policy enforcement failed due to internal system failure. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1330 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 633
, [SEC-1331], ,, ERROR, , Attempt to enable secure mode failed. Reason: . Probable Cause Indicates the secModeEnable command failed on the fabric because default IP Filter policies are not active on the switch, or an active transaction exists on - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 634
-number>, AUDIT, INFO, , Event: ipfilter, Status: failed, Info: Failed to save changes for ipfilter policies. Probable Cause Indicates that that the specified IP filter policy has not been saved. Recommended Action Verify that the security event was planned. If the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 635
Connection Type>. Probable Cause Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Action Severity INFO SEC-3050 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 636
90 SEC-3061 Recommended No action is required. Action Severity INFO SEC-3061 Message , [SEC-3061], , AUDIT, INFO, , Role is created. Probable Cause Indicates a role name was created. Recommended No action is required. Action Severity INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 637
Probable Cause Indicates the configuration of user-defined roles are downloaded. Recommended No action is required. Action Severity INFO SEC-4001 Message , [SEC-4001], , AUDIT, INFO, , Client logged in . Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 638
90 SEC-4001 562 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 639
Chapter SFLOW System Messages 91 SFLO-1001 Message , [SFLO-1001], ,, INFO, , sFlow is globally. Probable Cause Indicates that the sFlow is enabled or disabled globally. Recommended No action is required. Action Severity INFO SFLO-1002 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 640
INFO, , is as as sFlow collector. Probable Cause Indicates that the sFlow collector is either configured or not configured. Recommended No action is required. Action Severity INFO SFLO-1008 Message Probable Cause , [SFLO-1008], ,, INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 641
Recommended No action is required. Action Severity INFO 91 SFLO-1008 Fabric OS Message Reference 565 53-1001338-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 642
91 SFLO-1008 566 Fabric OS Message Reference 53-1001338-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 643
Cause Indicates the simple network management protocol (SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Verify the IP address for the Ethernet and Fibre Channel interface is set correctly. If the specified - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 644
-1006], , AUDIT, INFO, , configuration was reset to default Probable Cause Indicates the simple network management protocol (SNMP) configuration group was reset to the factory default. Recommended Execute the snmpConfig --show for the group - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 645
92 SNMP-1008 Severity INFO SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Execute the nsshow command to view the current device status. Action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 646
92 SNMP-1008 570 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 647
INFO SPC-1003 Message , [SPC-1003], ,, ERROR, , , Security Processor -bladed system, perform a fastboot command on the switch to recover the system. Severity ERROR Fabric OS Message Reference 571 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 648
the Crypto subsystem cover is tampered. Recommended EE is zeroized. User needs to run initEE and regEE. Action Severity CRITICAL SPC- ERROR, , , : FPGA firmware download failed: 0x%x. Probable Cause Indicates the FPGA download - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 649
Cause Indicates the FPGA download was successful. Recommended No action is required. Action Severity INFO SPC-2006 Message , [SPC-2006], ,, ERROR, , , : Crypto post tests failed: 0x%x. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 650
,, CRITICAL, , , : Tamper event: User zeroization. Probable Cause Indicates the Tamper event triggered due to a user zeroize request. Recommended EE is zeroized. Run the initEE and regEE commands. Action Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 651
key vaults such as RKM, recover the missing Master Key to current or alternate Action position. Severity ERROR SPC-3003 Message , [SPC-3003], ,, ERROR, , , : No output KEK for DEK rewrap, DEK: - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 652
• 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Contact technical support. Action Severity ERROR SPC-3006 Message , [SPC-3006], ,, ERROR, , , - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 653
Internal error Recommended For status code 14, complete primary KEK generation; otherwise, contact technical support. Action Severity ERROR SPC ERROR, , , : FIPS certificate mismatch, certificate: - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 654
regEE commands, then recover or restore the needed primary and secondary KEKs. Action Severity ERROR SPC-3013 Message Probable Cause , [SPC-3013], ,, ERROR, , , : SEK generation failure: - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 655
, : RSA pairwise key generation test failure. Probable Cause Indicates the Crypto Module could not generate its internal key pair. Recommended Contact technical support. Action Severity ERROR Fabric OS Message Reference 579 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 656
93 SPC-3015 580 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 657
initialize. Recommended Check the system resources and restart the switch. Action Severity ERROR SPM-1002 Message , [SPM-1002], , Set New Group Cfg SC Enable KV Type . Probable Cause Indicates a new group has been configured. Recommended No - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 658
INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause Indicates encryption engine (EE) control slot configuration. Recommended No action is required. Action Severity INFO SPM-1006 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 659
1009 Message , [SPM-1009], ,, ERROR, , Certificate is missing. ERROR SPM-1011 Message , [SPM-1011], ,, INFO, , Group Cfg Changed Quorum Size . Probable Cause Indicates that a group configuration - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 660
Recommended Use cryptocfg --sync -securitydb to manually sync security db. Action Severity ERROR SPM-1014 Message , [SPM-1014], Cause Indicates the Master Keys downloaded will not be effective unless imported as the EE may have different MK configured. Recommended Import required MK - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 661
94 SPM-3002 Recommended No action is required. Action Severity INFO SPM-3002 Message , [SPM-3002], ,, INFO, ,Event: cryptocfg Status: success, Info: EE in slot initialized. Probable Cause Indicates an encryption engine was initialized. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 662
Message , [SPM-3008], ,, INFO, ,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended No action is required. Action Severity INFO SPM-3009 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 663
-name>,Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault was registered. Recommended No action is required. Action Severity INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 664
>, [SPM-3015], ,, INFO, ,Event: cryptocfg Status: success, Info: Key vault type set to . Probable Cause Indicates the key vault type was set. Recommended No action is required. Action Severity INFO SPM-3016 Message , [SPM-3016], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 665
94 SPM-3018 Recommended No action is required. Action Severity INFO SPM-3018 Message , [SPM-3018], ,, INFO, ,Event: cryptocfg Status: success, Info: master key recovered. Probable Cause Indicates a master key was recovered. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 666
, [SPM-3024], ,, INFO, ,Event: cryptocfg Status: success, Info: Quorum size set to . Probable Cause Indicates the quorum size was set. Recommended No action is required. Action Severity INFO SPM-3025 Message Probable Cause , [SPM - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 667
94 SPM-3026 Recommended No action is required. Action Severity INFO SPM-3026 Message , [SPM-3026], ,, INFO, ,Event: cryptocfg Status: success, Info: File exported via usb: Source: Destination: . Probable Cause Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 668
94 SPM-3029 Recommended No action is required. Action Severity INFO 592 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 669
be displayed in this message due to possible errors in subcommands being executed by the supportSave command. Recommended Check the remote server settings. Run the supportFtp command to set the FTP or SCP parameters. Action After the problem is corrected, rerun the supportSave command. Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 670
errors in subcommands being executed by the supportSave command. Recommended Run the usbstorage command to check the USB storage device settings. After the USB problem >. Reason: No IP connection. Probable Cause Indicates the IP connection between Active switch and then run the supportsave - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 671
request. Probable Cause Indicates no reponse from the blade in the corresponding slot for the given supportsave request. Recommended Reboot the switch and then run the supportsave command. Action Severity WARNING SS-1008 Message , [SS-1008], ,, WARNING, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 672
95 SS-1008 596 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 673
cycle the switch. Severity ERROR SSMD-1002 Message , [SSMD-1002], ,, ERROR, ,Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the SSM has failed. Recommended Download a new firmware version - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 674
. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected, severe error during basic startup and initialization. Recommended Action Restart or power cycle the switch .If the condition persists then download a new firmware version using the firmwareDownload command - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 675
number> / . Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in initializing the dataplane ASIC QoS infrastructure. Recommended Restart or power cycle the switch. Action Severity WARNING SSMD-1205 Message , [SSMD-1205 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 676
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Default CoS feature. Recommended Delete and reapply the QoS interface Default CoS policy. Restart or power cycle the switch. Action Severity WARNING SSMD - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 677
the QoS interface CoS Mutation policy. Restart or power cycle the switch. Action Severity WARNING SSMD-1210 Message , [SSMD-1210], map. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 678
Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Pause feature. Recommended Delete and reapply the QoS Pause policy. Restart or power cycle the switch. Action Severity WARNING 602 Fabric - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 679
could not comply with FCoE scheduler policy for CEE Map . Probable Cause Indicates the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE configuration into an ETS scheduler policy implementable by the dataplane ASIC. Recommended Redefine CEE Map and FCoE into - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 680
96 SSMD-1303 SSMD-1303 Message , [SSMD-1303], ,, INFO, , CEEMap priority group with weight is created with pfc . Probable Cause Indicates that priority Group has been created. Recommended No action is required. Action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 681
SSMD-1310 Message , [SSMD-1310], ,, INFO, , ACL configured on interface . Probable Cause Indicates that Access List has been configured on an interface. Recommended No action is required. Action Severity INFO Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 682
timestamp>, [SSMD-1313], ,, INFO, , removed from interface . Probable Cause Indicates that user profile Map is removed from interface. Recommended No action is required. Action Severity INFO SSMD-1314 Message , [SSMD - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 683
The process is set to time out after 30 minutes. Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is required. The - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 684
>, [SULB-1007], ,, INFO, , Standby CP reboots. Probable Cause Indicates the standby CP is rebooting with new firmware. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 685
failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload failed due to IPC error." "Standby CP failed to reboot due to IPC error." 0x30 0x31 0x32 0x33 0x34 0x35 0x36 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 686
TABLE 6 Status Messages and Status Codes Status Message "firmwareCommit operation failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "Unable to restore the original firmware due to Standby CP timeout." "Standby CP failed to reboot and was not responding - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 687
started to restore the secondary partition." 0x93 "firmwareCommit failed." 0x94 "The secondary partition has been restored successfully." 0x95 "Firmware is being downloaded to the blade. This step may take up to 10 minutes." 0xa0 "firmwareDownload timed out." 0xa1 "Reboot occurred during - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 688
. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 689
of some common error messages: 0x15 - Failed to download Red Hat package manager (RPM) package. If this error occurs immediately after firmwareDownload is started, the firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 690
Another possible cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server. It may also - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 691
download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting switch service provider. Action Severity INFO SULB-1011 Message , [SULB-1011], ,, INFO, , Firmwaredownload command failed. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 692
the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message , [SULB-1021],, AUDIT, WARNING, , Firmware is being downloaded to the blade in slot . Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 693
during firmwaredownload. Probable Cause Indicates there may be an error caused by an unexpected disruption of the firmwareDownload command problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message , [SULB-1024], AUDIT, WARNING, , Firmware - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 694
progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message Probable Cause , [SULB-1031], , AUDIT, WARNING, , The switch is relocating an internal firmware image. Indicates the switch has rebooted with the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 695
Relocating an internal firmware image on the CP. Probable Cause Indicates the switch has started a firmware download to the problem persists, contact your switch service provider. Severity ERROR SULB-1035 Message , [SULB-1035], , AUDIT, ERROR, , An error - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 696
internal firmware image. It may also be caused by the internal Ethernet or persistent storage hardware failure. Recommended Reset the switch. This will cause the internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 697
Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload command again if the firmware is not updated. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 698
97 SULB-1040 622 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 699
. Recommended If the message persists, run the supportFtp command (as needed) to set up automatic FTP Action transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SWCH-1002 Message , [SWCH-1002], ,, INFO, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 700
, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR SWCH-1006 Message , [SWCH support N_Port ID Virtualization (NPIV) functionality, but the switch has some NPIV devices logged into the fabric. Recommended Load a firmware version on standby that supports - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 701
buffers, reduce the distance or speed settings for the port to reduce the buffer configuration that does not support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap the ports back to the ports default area. Refer to the Fabric OS Administrator's Guide - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 702
support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports has been enabled for one or more ports and the configuration file has been updated. Recommended No action is required. Action Severity INFO SWCH- - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 703
the software. This is usually an internal Fabric OS problem or due to file corruption. Recommended Action Restart or power cycle the switch If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING SWCH-1016 Message , [SWCH-1016], - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 704
device> tries to flogi, reject FLOGI as persistent PID is set on device and port has user area bound to it. Probable Cause Indicates a support dynamic area on default switch. Recommended Load a firmware version on the standby CP that supports dynamic area on default switch, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 705
might be a conflict between the two versions of firmware or the nonvolatile storage might be corrupted. Run supportFtp (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity CRITICAL SYSC-1002 Message , [SYSC - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 706
platform running this firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware. Severity CRITICAL action has failed. Recommended Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover Action command to recover - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 707
command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL SYSM-1002 Message , [SYSM-1002], ,, INFO, , , Switch: Probable Cause Indicates a user has - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 708
100 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Verify that the world - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 709
TAPE System Messages Chapter 101 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 710
101 TAPE-1001 634 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 711
supportFtp command to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity user> '. Probable Cause Indicates that a trace dump has occurred on the switch or the indicated slot and it is successfully transferred from the switch - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 712
to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity ERROR TRCE-1006 Message , [TRCE-1006], ,, INFO, , FTP Connectivity Test succeeded to FTP site ' - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 713
and retry the command. If the message persists, run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1008 Message , [TRCE-1008], , FFDC, CRITICAL, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 714
. Run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually transferred to target ' - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 715
occurs if the user name or password is incorrect. Recommended Action This message indicates a typing error by the user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 716
103 TRCK-1005 Probable Cause Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload command. This message is not generated for a configUpload command. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 717
FCS switch • External External NTP server address configured This might be logged during temporary operational issues such as IP network connection issues to the external clock server or if the fabric is configured for external time synchronization but the principal or primary FCS does not support - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 718
failed. Time Service exiting Probable Cause: Initialization error, Time switch is trying to set the tsclockserver, which is not the primary fabric configuration configuration server (FCS) switch. Another clock server in the list of clock servers configured is being used. This happens when the network - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 719
number>, should be Probable Cause Indicates the switch detected an inconsistency in the routing database between the routing protocol and the hardware configuration. The first port number displayed is what the hardware has configured and the second port number displayed is what the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 720
>, In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1026 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 721
zone is not compatible with the fabric configuration. Probable Cause Indicates the specified switch is unreachable because of the TI zone and the fabric configuration incompatibility. Recommended Clear all TI zones and refer to the TI zone user manual for instructions on how to create a valid TI - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 722
106 UPTH-1002 646 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 723
. Action Severity WARNING WEBD-1002 Message , [WEBD-1002], ,, WARNING, , Missing or Invalid Key file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL key file is either invalid or absent. Recommended Install a valid key - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 724
will be restarted due to change of IP Address. Probable Cause Indicates the IP address of the switch changed and the HTTP server is restarted. a rare error condition, where the built-in recovery process has failed to restore HTTP services. The problem often results from invalid configuration of SSL - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 725
If there was an unexpected job failure associated with this event, contact your customer support for Action assistance. Severity ERROR XTUN-1003 Message , [XTUN-1003], ,, ERROR, , Message Transmission failed:I/T/L: - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 726
by the Initiator. Recommended If there was an unexpected job failure associated with this event, contact your customer support for Action assistance. Severity ERROR XTUN-1998 Message , [XTUN-1998], ,, INFO, , FTRACE buffer - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 727
a possible network error or Action disruption has occurred. Severity ERROR XTUN-2002 ERROR XTUN-2004 Message Probable Cause , [XTUN-2004], ,, INFO, , FCIP Tunnel Pri QoS UP. Indicates that the specified quality of service - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 728
Class> Pri QoS DOWN . Probable Cause Indicates that the specified quality of service has gone down. This applies to the data classes only. If the f-class administratively disabled or deleted, a possible network error or Action disruption has occurred. Severity INFO 652 Fabric OS Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 729
ZEUS System Messages Chapter 109 ZEUS-1001 Message , [ZEUS-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 730
109 ZEUS-1001 654 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 731
files of the related modules (zoned, nsd, rcsd). If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command to save these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 655 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 732
110 ZOLB-1001 656 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 733
usually indicates problems when adding content-addressable memory (CAM) entries before the filter setup. Recommended If the message persists, run the supportFtp command (as needed) to set up automatic FTP Action transfers; then run the supportSave command and contact your switch service provider - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 734
define these zone members. Severity INFO ZONE-1006 Message , [ZONE-1006], ,, WARNING, , WARNING WWN ()in HARD PORT zone . Probable Cause Indicates that one or more devices are zoned as world wide name (WWN) devices and also zoned - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 735
setup. Recommended Action There are two ways to avoid this problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch only when enabling a zone configuration. Recommended Check the members - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 736
switch, it will not be supported. Recommended Edit the zone database to remove the QuickLoop zoning definition in the effective configuration. Action Severity WARNING ZONE-1014 Message , [ZONE-1014], ,, ERROR zone database by multiple administers. Recommended Wait - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 737
= 5) QuickLoop zones are not supported in Fabric OS v4.x and above. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR ZONE-1019 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 738
The effective configuration has changed to . Probable Cause Indicates the effective zone configuration has (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 739
Zone Config: The new config is not viable. • Zoning Operation failed: A zoning operation failed. • Shell exited: The command shell has exited. • Unknown: An error was received for an unknown reason. • User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 740
supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE- number>,, ERROR, , Switch is in interop mode. (switch, port) members not supported. Probable Cause Indicates the switch is set to - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 741
to rename to : error message . Probable Cause Indicates the Fabric OS cannot rename the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 742
-name>, Unable to read contents of : error message . Probable Cause Indicates the Fabric OS cannot read the zone configuration file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 743
change was done on purpose. If no effective zone configuration Action is needed, no action is necessary. Severity INFO ZONE-1043 Message , [ZONE-1043], ,, INFO, , The Default Zone access mode is set to No Access. Probable Cause Indicates the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 744
Probable Cause Indicates the Default Zone access mode is already set to All Access. Recommended No action is required. Action Severity INFO ZONE-1047 Message , [ZONE-1047], ,, INFO, , Switch domain () does not support defined database. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 745
is an AD-DefZone conflict. Recommended Check and resolve the default zone mismatch issue. Action Severity ERROR ZONE-1050 Message , [ZONE-1050], ,, INFO, , The Interop Safe Zoning mode is set to Enabled. Probable Cause Indicates that the Interop Safe - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 746
Remove frame redirection zones or set the defzone command to default zoning. Action Severity WARNING ZONE-1056 Message , [ZONE-1056], ,, WARNING, , Non-ETIZ-Capable Switch (dom ) in fabric w/ETIZ Configured. Probable Cause Indicates the config - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 747
, , TI Zone has domain running pre FOS6.4.0 firmware. TI member (Domain , Index ) is not supported. Probable Cause Indicates that an unsupported port index(> 511) is present in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 748
111 ZONE-1057 672 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 749
Audit Log Messages Section II This section provides the Audit messages, including: •AUDIT AG System Messages 675 •AUDIT AN System Messages 677 •AUDIT AUTH System Messages 679 •AUDIT BLS System Messages 683 •AUDIT CNM System Messages 685 •AUDIT CONF System Messages 689 •AUDIT CVLM System - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 750
674 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 751
that the F_Ports mapped to an N_Port have changed and the configuration file has been updated. Recommended No action is required. Action Severity INFO AG-1034 fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Fabric OS Message Reference 675 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 752
WARNING AG-1037 Message AUDIT, , [AG-1037], ,, INFO, ,Trunked N_Port () going offline, if switchshow CLI for the connected fabric switch port displays Persistently disabled: Area has been acquired, then check cabling: all trunked ports should be in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 753
AUDIT AN System Messages Chapter 113 AN-1003 Message , [AN-1003], ,, WARNING, , Slot , port is a latency bottleneck. percent of last - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 754
Bottleneck detection configuration is successfully changed. Probable Cause Indicates that the bottleneck detection configuration was changed by a user. Recommended a credit loss. Recommended Contact your vendor's customer support for assistance. Action Severity WARNING 678 Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 755
as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1046 Message database operation has been updated using the secAuthCertificate command. The values for Operation type can be "set" or "remove". Recommended - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 756
value>]. Probable Cause Indicates that an authentication configuration value was set to a specified value. The data type secret database operation has been updated using the secAuthSecret command. Name>, Status: failed, Info: Neighboring switch has a conflicting authentication policy; Port < - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 757
off. Probable Cause Indicates that the local switch has rejected the authentication request, because the switch policy is turned off. If the neighboring switch has a strict (ON) switch policy, the light will go off due to conflicting configuration settings. Otherwise the E_Port will form without - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 758
from the connected switch/device. The error might indicate that an invalid entity attempted to connect to the switch. Recommended Action supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 759
, , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec or IKE policy was added and the configuration file was updated. Recommended No action is required. Action Severity INFO BLS-1003 Message , [BLS-1003], ,, INFO, , An - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 760
115 BLS-1003 684 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 761
AUDIT CNM System Messages Chapter 116 CNM-3001 Message AUDIT, , [CNM-3001], INFO, , , , , Event: cryptocfg Status: success, Info: encryption group \\ created. Probable Cause Indicates an encryption group was created. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 762
-3007], INFO, , , , , Event: cryptocfg Status: success, Info: Heartbeat timeout set to . Probable Cause Indicates that the heartbeat timeout value was set. Recommended No action is required. Action 686 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 763
, , Event: cryptocfg Status: success, Info: Routing mode of EE in slot set to . Probable Cause Indicates that the encryption engine (EE) routing mode was set. Recommended No action is required. Action Severity INFO CNM-3009 Message AUDIT, , [CNM - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 764
is required. Action Severity INFO CNM-3012 Message AUDIT, , [CNM-3012], ,, INFO, , Deleteing an EG with luns setup for encryption can lead to luns being disabled if Encryption Group name is not preserved (). Probable Cause Indicates that the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 765
description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) not permitted . Probable Cause Indicates a configDownload - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 766
[CONF-1022], WARNING, CFG, , , , Downloading configuration without disabling the switch was unsuccessful. Probable Cause Indicates an attempt to download the configuration without disabling the switch was unsuccessful because there are one or more parameters - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 767
INFO, , , , , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates that the failback mode was set. Recommended No action is required. Action Severity INFO CVLM-3002 Message AUDIT, , [CVLM-3002 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 768
118 CVLM-3004 CVLM-3004 Message AUDIT, , [CVLM-3004], INFO, , , , , Event: cryptocfg Status: success, Info: Cluster member added to HA cluster . Probable Cause Indicates a HA cluster member was added to an HA cluster. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 769
-3009], INFO, , , , , Event: cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an encryption engine. Recommended No action is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 770
118 CVLM-3012 Recommended No action is required. Action Severity INFO CVLM-3012 Message AUDIT, , [CVLM-3012], INFO, , , , , Event: cryptocfg Status: success, Info: Initiator \\ removed from crypto target container \< - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 771
118 CVLM-3015 CVLM-3015 Message AUDIT, , [CVLM-3015], INFO, , , , , Event: cryptocfg Status: success, Info: Lun , attached through Initiator \\, removed from crypto target container \\. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 772
CVLM-3020 Message AUDIT, , [CVLM-3020], INFO, , , , , Event: cryptocfg Status: success, Info: Manual rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable Cause Indicates - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 773
118 CVLM-3022 CVLM-3022 Message AUDIT, , [CVLM-3022], INFO, , , , , Event: cryptocfg Status: success, Info: Resume rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 774
, , [CVLM-3028], ,, INFO, , Event: cryptocfg Status: success, Info: SRDF mode set to . Probable Cause Indicates that the SRDF mode was set. Recommended No action is required. Action Severity INFO 698 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 775
>, , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended No action is required. Action Severity INFO FCIP-1003 Message AUDIT, , [FCIP-1003], INFO, CFG, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 776
119 FCIP-1003 700 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 777
has been disabled. Recommended No action is required. Action Severity INFO FICU-1019 Message AUDIT, , [FICU-1019], ,, INFO, , Switch has been set offline by LP(%s). Probable Cause Indicates the Fibre Connectivity (FICON) Management server has disabled - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 778
120 FICU-1021 Recommended No action is required. Action Severity INFO FICU-1021 Message AUDIT, , [FICU-1021], ,, INFO, , Port Addrs (%s) have been UnBlocked by %s. Probable Cause Indicates the Fibre Connectivity (FICON) Management server has unblocked - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 779
AUDIT FW System Messages Chapter 121 FW-3001 Message AUDIT, , [FW-3001], INFO, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 780
121 FW-3001 704 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 781
, ZONE, , , , Zoning transaction initiated by User: , Role: could not be completed successfully - . Probable Cause Indicates an error occurred while completing the zoning transaction. Recommended Verify that the event - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 782
122 HTTP-1003 706 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 783
[IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 707 53 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 784
123 IPAD-1002 708 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 785
changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended No action is required. Action Severity INFO PORT-1007 Message AUDIT, , [PORT-1007 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 786
124 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 710 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 787
AUDIT SEC System Messages Chapter 125 SEC-1113 Message , [SEC-1113], ,, WARNING, , [ license ] going to expire in days. Probable Cause Indicates the license period will expire soon. Recommended Get a new license for this - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 788
be one of the following: • There has been an fabric configurations server (FCS) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. Recommended Action Verify the security event was planned. If - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 789
-details>, , , Event: , Status: success, Info: Removed members from policy . Probable Cause Indicates a user has removed the specific members from the specified security policy. Note: If you use a wildcard (for example, an asterisk) in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 790
-3011], INFO, SECURITY, , , , Event: , Status: success, Info: Reset [] statistics on domains []. Indicates that a user has reset a security statistic on the specified domains. 714 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 791
: Temp Passwd on domain [] for account []. Probable Cause Indicates a user has reset the password for the specified user accounts. Recommended Action Verify the password was intentionally reset. If the password was intentionally reset, no action is - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 792
: success, Info: Moved RADIUS server to position . Probable Cause Indicates a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify the RADIUS server position was intentionally changed. If the RADIUS - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 793
, Info: Passwdcfg parameters set to default values. Probable Cause Indicates the passwdCfg parameters are set to default values. Recommended Action Verify attempt via . Probable Cause Indicates a successful login occurred. An IP address is displayed when the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 794
may manually unlock the account. Severity INFO SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Probable Cause Indicates the user's password - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 795
>, [SEC-3025], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], AD list []. Probable Cause Indicates a new - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 796
, SECURITY, , , , Event: , Status: success, Info: Backup user account \"\" recovered. Probable Cause Indicates that back user accounts were recovered. Recommended Action Verify the security event was planned. If the security - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 797
, Status: success, Info: Switch is configured to - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 798
3038], INFO, SECURITY, , , , Event: ipfilter, Status: failed, Info: Failed to activate . Probable Cause Indicates the specified IP filter policy failed to activate. Recommended Action Verify the security event was planned. If the security - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 799
The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through >, , FIPS self tests mode has been set to . Indicates there was a change in the FIPS Self Test mode. Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 800
-initiator-details>, , RBAC permission denied for CLI : . Probable Cause Indicates the user does not have permission to execute this command. Recommended Verify the user has the required permission to execute this command. Action Severity INFO SEC-3048 Message AUDIT - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 801
SEC-3051 125 Probable Cause Indicates the specified sshutil operation was performed.. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 802
of user-defined roles is downloaded. Probable Cause Indicates the configuration of user-defined roles are downloaded. Recommended No action is required. Action Severity INFO SEC-4001 Message , [SEC-4001], , AUDIT, INFO, , Client logged in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 803
Probable Cause Indicates the client has logged in. Recommended No action is required. Action Severity INFO SEC-4001 125 Fabric OS Message Reference 727 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 804
125 SEC-4001 728 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 805
that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP-1005 Message AUDIT, , [SNMP-1005], INFO, CONFIGURATION, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 806
126 SNMP-1006 730 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 807
AUDIT SPM System Messages Chapter 127 SPM-3001 Message AUDIT, , [SPM-3001], INFO, , ,,Event: cryptocfg Status: success, Info: Node initialized. Probable Cause Indicates a node was initialized. Recommended No action is required. Action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 808
127 SPM-3005 Probable Cause Indicates an encryption engine was enabled. Recommended No action is required. Action Severity INFO SPM-3005 Message AUDIT, , [SPM-3005], INFO, , ,,Event: cryptocfg Status: success, Info: EE in slot disabled. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 809
, , [SPM-3008], INFO, , ,,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended No action is required. Action Severity INFO SPM - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 810
. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault Status: success, Info: Key vault type set to . Probable Cause Indicates the key vault type was set. Recommended No action is required. Action 734 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 811
SPM-3016 127 Severity INFO SPM-3016 Message AUDIT, , [SPM-3016], INFO, , ,,Event: cryptocfg Status: success, Info: Master key generated. Probable Cause Indicates a master key was generated. Recommended No action is required. Action Severity - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 812
127 SPM-3020 Severity INFO SPM-3020 Message AUDIT, , [SPM-3020], INFO, , ,,Event: cryptocfg Status: success, Info: System card with certificate label \"\" deregistered. Probable Cause Indicates a system card was deregistered. - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 813
SPM-3024], INFO, , ,,Event: cryptocfg Status: success, Info: Quorum size set to . Probable Cause Indicates the quorum size was set. Recommended No action is required. Action Severity INFO SPM-3025 Message AUDIT, , [SPM-3025], INFO - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 814
127 SPM-3028 Probable Cause Indicates a recovery card was registered. Recommended No action is required. Action Severity INFO SPM-3028 Message AUDIT, , [SPM-3028], ,, INFO, , Event: SPM-EE state changed, Info: EE State: . Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 815
set to time out after 30 minutes. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption. Do not fail over or power down the system during firmware has completed successfully and switch firmware has been updated. Recommended Action No action - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 816
failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload failed due to IPC error." "Standby CP failed to reboot due to IPC error." 0x30 0x31 0x32 0x33 0x34 0x35 0x36 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 817
TABLE 9 Status Messages and Status Codes Status Message "firmwareCommit operation failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "Unable to restore the original firmware due to Standby CP timeout." "Standby CP failed to reboot and was not responding - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 818
started to restore the secondary partition." 0x93 "firmwareCommit failed." 0x94 "The secondary partition has been restored successfully." 0x95 "Firmware is being downloaded to the blade. This step may take up to 10 minutes." 0xa0 "firmwareDownload timed out." 0xa1 "Reboot occurred during - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 819
. Check whether the switch is supported by the requested firmware. Also check firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 820
of some common error messages: 0x15 - Failed to download Red Hat package manager (RPM) package. If this error occurs immediately after firmwareDownload is started, the firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 821
Another possible cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server. It may also - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 822
to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. problem persists, contact your switch service provider. Severity ERROR SULB-1018 Message Probable Cause AUDIT, , [SULB-1018], ERROR, FIRMWARE - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 823
blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 824
command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1024 Message AUDIT, , [SULB-1024], WARNING, FIRMWARE, , , , Firmware commit has completed on the blade in slot - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 825
command to monitor progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message AUDIT, , [SULB-1032], WARNING, FIRMWARE, , , , Relocating an internal firmware image on the CP. Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 826
. Recommended Reset the switch. This will cause the internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, HCL failed. Reboot the switch manually using the - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 827
Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload command again if the firmware is not updated. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 828
128 SULB-1040 752 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 829
been enabled for one or more ports. Probable Cause Indicates a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended No action is required. Action Severity INFO SWCH-1013 Message AUDIT, , [SWCH-1013], INFO, CFG, - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 830
129 SWCH-1014 754 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 831
details>, , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1022 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 832
>, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required. Action Severity INFO UCST-1026 Message - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 833
Severity INFO 130 UCST-1027 Fabric OS Message Reference 757 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 834
130 UCST-1027 758 Fabric OS Message Reference 53-1001767-01 - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 835
Probable Cause Indicates that a new zone object member or members have been added to the specified zone object set. The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 836
Probable Cause Indicates the specified zone object member or members have been removed from the specified zone object set. The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 837
, ZONE, , , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been enabled. Recommended Verify the event was planned. If the event was - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 838
, FABRIC, , , , Event: , Status: success, Info: \"\" added to \"\". Indicates the specified new admin domain (AD) object member or members have been added to the specified AD object - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 839
Probable Cause Indicates all admin domain (AD) definitions and all zone configurations under them have been cleared. Recommended Verify the event was planned. , Status: success, Info: \"\" created with \"\". Probable Cause - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 840
, , , , Event: , Status: success, Info: \"\" removed from \"\". Probable Cause Indicates the specified admin domain (AD) member or members have been removed from an AD. Recommended - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 841
INFO, FABRIC, , , , Event: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates the current admin domain (AD) configuration has been saved to flash. Recommended Verify the event was planned. If the event was - HP 8/80 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 842
131 ZONE-3025 Severity INFO 766 Fabric OS Message Reference 53-1001767-01
53-1001767-01
30 March 2010
®
Fabric OS
Message Reference
Supporting Fabric OS v6.4.0