HP 8/80 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 371
FW-1052, FW-1113, FW-1114
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 371 highlights
42 FW-1052 Recommended Frequent voltage fluctuations are an indication that the SFP is deteriorating. Replace the SFP. Action Severity WARNING FW-1052 Message , [FW-1052], ,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value outside of the acceptable range to a value within the acceptable range. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1113 Message , [FW-1113], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the number of times E_Ports have gone down has changed. E_Ports go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. Recommended Check both ends of the physical connection and verify that the SFPs and cables are functioning Action properly. Severity INFO FW-1114 Message , [FW-1114], ,, INFO, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the number of times E_Ports have gone down has fallen below the low boundary. E_Ports go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of E_Port failures means that the switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO Fabric OS Message Reference 295 53-1001767-01