HP 8/80 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 452
HIL-1309, HIL-1310, HIL-1311, HIL-1401
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 452 highlights
45 HIL-1309 Recommended Replace the faulty fan field-replaceable units (FRUs) immediately. Action Severity ERROR HIL-1309 Message , [HIL-1309], ,, ERROR, , fan FRUs failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed message. Recommended Replace the faulty fan field-replaceable unit (FRU)s immediately. Action Severity ERROR HIL-1310 Message , [HIL-1310], ,, WARNING, , fans faulty. Probable Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed message. Recommended Since the fans are not field replaceable, replace the switch if the temperature is high. Action Severity WARNING HIL-1311 Message , [HIL-1311], ,, INFO, , No fans are faulty. Probable Cause Indicates recovery from earlier condition of one or more fans having failed. Recommended Action This can only occur on switches with non-removable fans. It follows a previous indication of faultiness. If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty behavior. Replace the switch because the fan is not field-replaceable. Severity INFO HIL-1401 Message , [HIL-1401], ,, WARNING, , One fan FRU missing. Install fan FRU immediately. 376 Fabric OS Message Reference 53-1001767-01