HP 8/80 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 422
FW-1442, Replace the FRU.
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 422 highlights
42 FW-1442 Severity INFO FW-1442 Message , [FW-1442], ,, INFO, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to "on". Recommended No action is required. Verify that the event was planned. Action Severity INFO FW-1443 Message , [FW-1443], ,, INFO, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) changed to "off". Recommended No action is required. Verify that the event was planned. Action Severity INFO FW-1444 Message , [FW-1444], ,, WARNING, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to "faulty". Recommended Replace the FRU. Action Severity WARNING FW-1445 Message Probable Cause , [FW-1445], ,, INFO, , Four power supplies are now required for 2X redundancy, Switch Status Policy values changed. Indicates that the switch now requires 4 power supplies and previous Switch Status Policy parameters will be overwritten to reflect this. The presence of an AP blade means that more than one power supply may be required to provide adequate power. So (even if the AP blade is powered down or removed) the Switch Status policy values will now reflect the need for 4 power supplies to maintain full (2X) redundancy. 346 Fabric OS Message Reference 53-1001767-01