42 FW-1012 Recommended Set the high boundary above the normal operation range. Action Severity INFO FW-1012 Message , [FW-1012], ,, INFO, , , is between high and low boundaries(High=, Low=). Current value is . Probable Cause Indicates that the power supply counter changed from a value outside of the acceptable range to a value within the acceptable range. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1033 Message , [FW-1033], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) has changed. Frequent fluctuations in SFP temperature might indicate a deteriorating SFP. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1034 Message , [FW-1034], ,, WARNING, , , is below low boundary(High=, Low=). Current value is . Probable Cause Indicates that the temperature of the small form-factor pluggable (SFP) has fallen below the low boundary. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity WARNING Fabric OS Message Reference 289 53-1001767-01