HP 8/80 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 363
FW System Messages, FW-1001
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 363 highlights
Chapter FW System Messages 42 FW-1001 Message , [FW-1001], ,, INFO, , , value has changed(High=, Low=). Current value is . Probable Cause Indicates that the internal temperature of the switch has changed. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. To prevent recurring messages, disable the changed alarm for this threshold. Severity INFO FW-1002 Message , [FW-1002], ,, WARNING, , , is below low boundary (High=, Low=). Current value is . Probable Cause Indicates that the internal temperature of the switch has fallen below the low boundary. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Typically, low temperatures means that the fans and airflow of a switch are functioning normally. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. Severity WARNING FW-1003 Message , [FW-1003], ,, WARNING, , , is above high boundary(High=, Low=). Current value is . Probable Cause Indicates that the internal temperature of the switch has risen above the high boundary to a value that might damage the switch. Recommended This message generally appears when a fan fails. If so, a fan failure message accompanies this Action message. Replace the fan field-replaceable unit (FRU). Severity WARNING Fabric OS Message Reference 287 53-1001767-01