12 Specifications This section provides specifications for your computer. Table 12-1 Specifications Metric U.S. Dimensions Height Width 337 mm 384 mm 13.27 in 15.12 in Depth 100 mm 3.94 in Approximate weight Temperature range 6.44 kg 14.2 lb Operating Nonoperating 5°C to 40°C -40°C to 66°C 41°F to 104°F -40°F to 151°F NOTE: Operating temperature is derated 1.0°C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10°C/Hr. The upper limit might be limited by the type and number of options installed. Maximum altitude (unpressurized) Operating 5,000 m 16.404 ft Nonoperating Relative humidity (noncondensing) 15,240 m 50,000 ft Operating 5% to 90% Nonoperating (38.7°C max wet bulb) Power supply 5% to 90% 250 W Operating voltage range Rated voltage range1 Rated line frequency 90 V AC to 264 V AC 100 V AC to 240 V AC 50 Hz to 60 Hz Operating line frequency 47 Hz to 63 Hz 1 This system uses an active power factor-corrected power supply. This allows the system to pass the CE mark requirements for use in the countries of the European Union. The active power factor-corrected power supply also has the added benefit of not requiring an input-voltage range select switch. Specifications 107