Table 6-1 POST numeric codes and text messages (continued) Control panel message Description Recommended action 00D-Setup Error during MEBx Execution MEBx selection or exit resulted in a setup 1. failure. 2. Reboot the computer. Unplug the power cord, reseat the memory modules, and reboot the computer. 3. If the memory configuration was recently changed, unplug the power cord, restore the original memory configuration, and reboot the computer. 4. If the error persists, replace the system board. 00E-Inventory Error during MEBx Execution BIOS information passed to the MEBx resulted in a failure. 1. Reboot the computer. 2. If the error persists, update to the latest BIOS version. 3. If the error still persists, replace the system board. 00F-Interface Error during MEBx Execution MEBx operation experienced a hardware 1. error during communication with the ME. 2. Reboot the computer. If the error persists, update to the latest BIOS version. 3. If the error still persists, replace the system board. 100-Front Audio Not Connected Front audio cable has been detached or Reconnect or replace front audio cable. unseated from system board. 2E1-MemorySize Error Memory amount has changed since the last boot (memory added or removed). The system memory size is different from the last startup. The most common reason is the removal of memory from the system board. Press the f1 key to save the memory changes. 2E2-Memory Error Memory module configuration failed during boot-up. 1. Be sure that memory modules are correctly installed. 2. Verify proper memory module type. 3. Remove and replace the identified faulty memory modules. 4. If the error persists after replacing memory modules, replace the system board. 2E3-Incompatible Memory Module in Memory Socket(s) X, X, ... A memory module in memory socket identified in the error message is missing critical SPD information, or is incompatible with the chipset. 1. Verify proper memory module type. 2. Try another memory socket. 3. Replace with a supported module. 2E4-DIMM Configuration Warning Populated DIMM Configuration is not optimized. Rearrange the DIMMs so that each channel has the same amount of memory. 82 Chapter 6 POST error messages