- HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 1
hp Integrity rx1620 Installation Guide Regulatory Model Number: RSVLA-0406 Second Edition Manufacturing Part Number: AB430-96004 February 2005 U.S.A. © Copyright 2005 Hewlett-Packard Development Company, L.P.. - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 2
. It contains a complete documentation set for the server, including localized versions of key documents. Included on the CD-ROM are the Site Preparation, Operations , and Maintenance guides, which contain in-depth troubleshooting, installation, and repair information. The CD will autorun when you - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 3
27 Installing Additional Memory 34 Supported DIMM sizes 34 DIMM Locations 35 Installing DIMMs 36 Installing Additional PCI Cards 38 Installing a PCI Card 38 Optional Management Processor Card (MP 42 4. Troubleshooting Troubleshooting Tips 47 Troubleshooting Methodology 47 Possible Problems - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 4
Using CLI 69 Troubleshooting Example Using CLI 69 LAN LEDs 70 Rear Panel LAN LEDs 70 LAN A Connector LEDs 70 LAN B Connector LEDs 70 Optional Management Processor LAN C Connector LEDs 71 System Board Diagnostic LEDs 72 Running Diagnostic Software Tools 73 HP e-DiagTools Hardware Diagnostics - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 5
LED Indicators 17 Figure 3-4. DVD 18 Figure 3-5. Rear View 19 Figure 3-6. Front View of the hp Integrity rx1620 Server 21 Figure 3-7. Filler Removal from Slot 1 22 Figure 3-8. Disk Drive Installation in Slot 1 23 Figure 3-9. Removing and Replacing the Cover 24 Figure 3-10. Aligning the Cover - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 6
Figures 6 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 7
appropriate product support service. See your HP sales representative for details. IMPORTANT The latest version of this document can be found online at http://docs.hp.com. What's in This Document The hp Integrity rx1620 Installation Guide contains these chapters: • Chapter 2, "Server Overview and - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 8
. It contains a complete documentation set for the server, including localized versions of key documents. Included on the CD-ROM are the Site Preparation, Operations, and Maitenance guides, which contain in-depth troubleshooting, installation, and repair information. The CD will autorun when you - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 9
of processor, memory, and PCI cards are used and where are they installed? • What accessories are installed? Step 4. Determine the following: • Which firmware versions are in use? • When did the problem start? • Have recent changes been made to the system? • Which operating system and version - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 10
About This Document Where to Get Help 10 Chapter 1 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 11
Server Overview The hp Integrity rx1620 Server is a two-way IPF rack-mount server based on the Itanium® processor family architecture. The hp Integrity rx1620 Server accommodates up to 8 DIMMs and internal peripherals including disks and DVD-ROM. The supported operating systems include HP - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 12
Server Overview and Unpacking Server Overview Figure 2-2 hp Integrity rx1620 Server (Front View with Bezels Removed) Figure 2-3 hp Integrity rx1620 Server (Rear View) 12 Chapter 2 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 13
form and return it to the shipping representative. Installing the Server into a Rack HP Rack Any hp Integrity rx1620 Server that is to be installed into a rack is shipped with equipment slides. With every set of slides comes an installation guide: Installation Guide, Mid-Weight Slide Kit, 5065-7291 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 14
Server Overview and Unpacking Unpacking the Server 14 Chapter 2 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 15
rear panels and procedures required in installing additional components and configuring the hp Integrity rx1620 Server. Control Panel The control panel of the hp Integrity rx1620 Server provides the controls and indicators commonly used for operation. Figure 3-1 Front View DVD Drive Control - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 16
On/Off The green on/off LED is illuminated when the power is on. LED Power On/Off This is the power on/off switch for the server. Button System LED The System LED provides information about the system status. When operation is normal, the LED is green. When there is a system warning, the LED - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 17
and Configuring Additional Controls and Indicators Additional Controls and Indicators The hp Integrity rx1620 Server can have up to two low-voltage differential (LVD), 3.5 inch form factor hard disk drives installed. These hard disk drives have LEDs that provide status and activity information - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 18
Installing and Configuring Additional Controls and Indicators Optional Removable Media Drive The hp Integrity rx1620 Server is delivered without a removable media drive. Either a DVD or CD-RW/DVD drive may be added. Each of these optional devices has one activity LED. - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 19
Installing and Configuring Rear Panel Rear Panel The hp Integrity rx1620 Server rear panel includes communication ports, I/O ports, AC power connector, and the locator LED/button. Figure 3-5 Rear View Optional Management Board Connectors AC Power Receptacle 10/100 Video LAN C Serial PCI - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 20
Installing and Configuring Service Tools Required Table 3-4 Rear Panel Connectors and Switches (Continued) Connector/Switch Function Locator Button and LED Video (optional) Serial (optional) 10/100 LAN C (optional) The locator button and LED are used to help locate a server within a rack of - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 21
system is running. If the operating system does not support this feature, shut down the operating system before attempting this procedure. Failure to observe this caution will result in system failure. Figure 3-6 Front View of the hp Integrity rx1620 Server 0 1 LVD HDD 2 Slot 1 LVD HDD - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 22
Internal Hard Disk Drives CAUTION If the HP Server is to be operated with only a single hard disk drive installed, the hard disk drive slot filler must be installed to insure proper cooling. If a hard disk drive is installed in slot 1, retain the slot filler to be reinstalled if the drive - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 23
, at the EFI shell prompt input shell> info io to interrogate the system for proper identification of the drive. b. If the server has a management processor installed, use the management processor command MP> df to interrogate the system for proper identification (FRUID) of the drive. Chapter 3 23 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 24
the Cover CAUTION Do not operate the server without the cover in place. Operation of the server without the cover in place will result in system failure. Operation of the server without the cover in place will make the server susceptible to EMI and overheating problems. Observe all ESD safety - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 25
Installing and Configuring Removing and Replacing the Cover Step 1. Open the cover by moving the latch handle counter-clockwise. Step 2. Slide the cover toward the rear - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 26
section provides information about installing processors and memory. The processors and memory slots are located on the system board, which is accessible by removing the system cover. WARNING Voltages are present at various locations within the server whenever an AC power source is connected. This - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 27
in "Parts Information" in the hp Integrity rx1620 Maintenance Guide. Processor Load Order Processors are located on the system board. The system board can support either one or two processors. CPU 0 is located to the right of the system board and CPU 1 (when installed) is located on the left of - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 28
4. If the CPU dust cover is installed, remove the CPU dust cover. CAUTION If the HP Server is to be operated with only a single processor installed, the CPU airflow blocker must be installed to ensure proper cooling. If a second processor is installed in location CPU 1, retain the airflow blocker - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 29
and Configuring Installing Processors and Memory CAUTION The zero insertion force (ZIF) socket for the processor is . Figure 3-14 Unlocking the Processor Locking Mechanism 5NLOCKED ,OCKED Front of server Step 6. Remove the pin cover and protective caps for the captive screws on the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 30
and Configuring Installing Processors and Memory Step 7. Place the processor and heatsink assembly over the processor socket. Use the four locator posts on the assembly to align with the locator holes on the system board. Make certain that the connector that will mate with the processor power pod is - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 31
and Configuring Installing Processors and Memory Step 8. Use the special processor tool (P/N 5069-5441) 180 degrees. Figure 3-16 Locking the Processor Assembly in Place 5NLOCKED ,OCKED Front of server IMPORTANT Before proceeding to step 9, make sure the processor is locked in place on the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 32
Installing and Configuring Installing Processors and Memory Step 10. Slide the power module on the system board metal mounting bracket forward to mate the power module connector with the processor connector. Figure 3-18 Connecting the Processor Power Pod &RONT - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 33
Installing and Configuring Installing Processors and Memory Step 12. Connect the power pod cable to the power connector on the system board. Figure 3-20 Connecting the Power Cable &RONT - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 34
Additional Memory Installing Additional Memory The hp Integrity rx1620 Server has 8 memory sockets for installing DDR SDRAM memory modules. These memory modules can either be 256MB, 512MB, 1GB, or 2GB size. The system supports combinations from 512 MB up to 16GB. Supported DIMM sizes Supported DIMM - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 35
Figure 3-21 DIMM Loading Order Rear Installing and Configuring Installing Additional Memory Front 2A Pair 4 1A 2B Pair with the loading order being slot 0, slot 1, slot 2 and slot 3. The memory subsystem supports chip spare functionality. Chip spare enables an entire SDRAM chip on a DIMM to be - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 36
Installing and Configuring Installing Additional Memory Each DIMM within a quad must be identical to all the other DIMMs in the quad. Figure 3-22 DIMM Locations DIMM DIMM DIMM DIMM Slot 1B Slot 2B Slot 1A Slot 2A DIMM DIMM DIMM DIMM Slot 0B Slot 3B Slot 0A Slot 3A Installing DIMMs To install - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 37
modules are not damaged during removal or installation, power off the server and unplug the power cord from the AC power outlet. Wait until the power on/off LED on the control panel turns off before removing or installing memory. Observe all ESD safety precautions before attempting this procedure - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 38
DC to ensure that the memory is functional Installing Additional PCI Cards The server may contain up to 2 PCI cards. PCI cards are located on the I/O riser assembly. WARNING Ensure that the system is powered-down and all power sources have been disconnected from the server prior to removing or - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 39
Installing and Configuring Installing Additional PCI Cards Step 2. Release the PCI I/O riser by turning the jackscrew. This action frees the PCI I/O riser from the system board. Figure 3-24 Using Jackscrew to Release PCI I/O Riser Chapter 3 39 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 40
Installing and Configuring Installing Additional PCI Cards Step 3. Remove the PCI I/O Riser from the chassis. Figure 3-25 Removing the PCI I/O Riser Assembly 40 Chapter 3 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 41
PCI Slot Cover Installing and Configuring Installing Additional PCI Cards Step 5. Grasp the edges of the PCI card being installed and gently press be installed in slot 1, the top slot of the PCI I/O riser assembly. The lower slot (slot 2) can only accept half length cards. Figure 3-27 Installing - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 42
available whenever the system is connected to a power source, even if the hp Integrity rx1620 Server main power switch is in the off position. Access to the management processor can be restricted by user accounts. User accounts can be password protected and provide a specific level of access to the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 43
Installing and Configuring Optional Management Processor Card (MP) Step 4. Remove the blank retaining tab out of its socket on the system chassis and remove the blank - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 44
Installing and Configuring Optional Management Processor Card (MP) Step 9. Screw in the two mounting screws that connect the MP card to the internal chassis post. Figure 3-29 Connecting the Management Processor Card 44 Chapter 3 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 45
Figure 3-30 Installing the External Mounting Posts Step 11. Replace the system cover and reconnect the power and external cables. Information required to access, configure, and utilize the management processor is provided under "Utilities" in the hp Integrity rx1620 Operations Guide. Chapter 3 45 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 46
Installing and Configuring Optional Management Processor Card (MP) 46 Chapter 3 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 47
This chapter provides troubleshooting instructions used in the maintenance of the hp Integrity rx1620 Server. Troubleshooting Tips WARNING Before removing a cover, always disconnect the AC power cord and unplug cables. Disconnect the AC power cord to avoid exposure to high energy levels - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 48
need to restore customer specific information. Possible Problems This section contains example HP Server problems and their possible solutions. The system will not power-up. Step 1. Review the installation procedures for the server. Refer to Chapter 3, "Installing and Configuring." Step 2. Check - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 49
processor has a power pod installed. Also verify that the processors are of the same type. Step 11. Check the boot order with the SCSI configuration utility. Step 12. If there are no obvious errors, reflash the BMC firmware. Refer to "Utilities" in the hp Integrity rx1620 Operations Guide. Step 13 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 50
and turn on the server. If your server now works, check the installation instructions received with the new board for correct installation method. If the new board is preventing the server from powering on, it is likely to have a serious electrical problem. Step 7. If the server still does not work - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 51
for proper ventilation for the server. The server should have at least three inches of space around the front and rear for proper airflow when installed in a rack. NOTE Temperature problems may be caused by a fluctuating power supply. Step 6. Check the system specifications and make sure the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 52
be lit. • Standby LED on system board is on steady. 3. Check for an EFI shell prompt (CTRL+B) at console. • No AC present • Power supply • Power distribution • System board • Display board • BMC "heartbeat" LED on system board is flashing.(if installed) should be lit solid green. 52 Chapter 4 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 53
• Processor support modules (also known as power pods). • Memory 3. Check for a red LED on the MP card if installed. If lit red, the problem is with the MP. • Processors • Processor support modules • Memory • System board • Console 4. Reduce to minimum configuration and troubleshoot from there - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 54
Hard Disk Drive Operation Table 4-1 Problem Symptoms Repair Actions (Continued) Problem or Symptom Cannot boot to initial system loader (ISL) Problem Indicators Normal Functioning Indicators Troubleshooting Steps Potential FRUs • Console messages indicating problems booting from the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 55
Troubleshooting Verifying Hard Disk Drive Operation NOTE On the hp Integrity rx1620 Server only the Activity LED is shows the correct activity indication for all disk drives that you installed: Step 1. Turn on power to the HP Server and display monitor. Step 2. During the boot sequence, watch the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 56
are experiencing, HP also provides diagnostic tools with each operating system. Power and System LEDs The Power and System LEDs indicate the state of the system. When the System LED is blinking yellow or red, a problem exists. NOTE When the optional management processor (MP) card is installed, the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 57
Troubleshooting Identifying and Diagnosing Hardware Problems Table 4-2 System LED States (Continued) System LED Blinking red (2/sec.) Fault indication: State System alert level 7 detected, LED will blink until the problem is resolved and the system boots successfully or until it is manually - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 58
Troubleshooting Identifying and Diagnosing Hardware Problems Step 5. For a complete explanation of configuring the management processor and using the MP commands, see "Utilities" in the hp Integrity rx1620 Operation Guide to Quit: Step 3. Select e to review the system events. The Event Log Navigation - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 59
Troubleshooting Identifying and Diagnosing Hardware Problems L Last entry J Jump to entry number H View mode configuration - Hex K View mode configuration - Keyword T View mode configuration - Text A Alert Level Filter options U Alert Level Unfiltered ? - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 60
Troubleshooting Identifying and Diagnosing Hardware Problems L Last entry J Jump to entry number V Text mode Enter new value, or [Q] to Quit: Step 6. To decode the blinking state of system LED, review the entire SEL and look at events with alert level 3 and above. For example: Log Entry 24: 14 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 61
is presented under "Utilities" in the hp Integrity rx1620 Operations Guide. Systems without a Management Processor Card The system LED states operate the same with systems having the optional management processor card. Table 4-3 Power and System LED States Power LED Off On (green) On (green - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 62
Troubleshooting Identifying and Diagnosing Hardware Problems • If a management processor card is installed, the boot process will be monitored by the management processor card. The diagnostic LEDs are disabled. Figure 4-2 Diagnostic LEDs LED 2 LED 4 System LED 1 LED 3 LED Power specific error - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 63
your HP Support Engineer. Table 4-6 Memory Warnings System LED Flashing Yellow Flashing Yellow Flashing Yellow LED 1 LED 2 LED 3 LED 4 Problem Solution Red Green Off Off Mismatched View the SEL for additional memory information. Review the pairs. information on installing memory in - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 64
.a a. Refer to the hp Integrity rx1620 Maintenance Guide for detailed instructions on the maintenance action. Table 4-9 Processor Warnings System LED Flashing Yellow Flashing Yellow LED 1 LED 2 LED 3 Red Red Green Red Red Off LED 4 Off Green Problem Solution Processor 0 Make sure - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 65
, contact your HP Support Engineer. Table 4-14 Memory Faults System LED Flashing Red Flashing Red Flashing Red LED 1 LED 2 Red Green Off Off Red Green LED 3 Off Off Green LED 4 Problem Solution Off Green Off Mismatched memory pairs. Fatal memory error. No memory installed. Review the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 66
Troubleshooting Identifying and Diagnosing Hardware Problems Table 4-14 Memory Faults (Continued) System LED Flashing Red LED 1 LED 2 Red Green LED 3 Green LED 4 Problem Solution Green Bad Memory. One or more DIMMs are bad or not seated properly. Reseat the DIMMs. If the error persists, - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 67
Troubleshooting Identifying and Diagnosing Hardware Problems a. Refer to the hp Integrity rx1620 Maintenance Guide for detailed instructions on the maintenance action. Table 4-18 Processor Faults System LED Flashing Red Flashing Red Flashing Red LED 1 LED 2 LED 3 Red Red Green Red Red Off - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 68
the BMC console commands or command line interface (CLI). The commands are similar to the management processor (MP) commands but are slightly less interactive. Detailed information on the CLI commands is provided under "Utilities" in the hp Integrity rx1620 Operations Guide. Command Line Interface - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 69
Command Line Interface Troubleshooting Example Using CLI This example uses the cli and the SEL to display error messages indicating that no memory is installed. cli>sl e # Sev Generator/Sensor Description Event ID Data, Timestamp 00A0 - SFW 00B0 7 CPU0 00C0 7 CPU0 00D0 - SFW 00E0 7 CPU0 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 70
Troubleshooting LAN LEDs LAN LEDs The front panel LAN LED indicates the system is communicating over the Gigabit or system management LAN: • Blinking green, the system - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 71
four LEDs on the rear panel if the management processor card is installed: Table 4-24 Optional Management Processor Card LAN C LEDs LAN LED Self-test Top Location 10BT 2nd from top 100BT 2nd from bottom Standby Power Bottom Color Yellow Off Green Blinking green Off Green Blinking green - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 72
LEDs There are three additional LEDs that can help when troubleshooting the system. These LEDs are located on the system board the system is plugged in, check the AC power cord, reseat the power supply, and if this does not work, replace the power supply. A few seconds after the system is plugged - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 73
hardware configuration. • Provide precise information to an HP support agent so they can solve problems quickly and effectively. HP e-DiagTools provides a user-friendly interface to the Offline Diagnostics Environment (ODE), that enables you to troubleshoot a system that is running without an OS or - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 74
Troubleshooting Running Diagnostic Software . 11/07/02 04:41p 0 .. 11/07/02 04:41p 1,024 HP 11/07/02 04:45p 1,024 BOOT 0 File(s) 0 bytes 4 Dir(s) c. Change launchmenu Step 5. If you are not familiar with e-DiagTools, review the documentation. From the main menu: a. Select View - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 75
Troubleshooting Running Diagnostic Software Tools Producing a Support Ticket To produce a complete record of your system's configuration and test results, you must create a support ticket. This is a simple text file that contains essential information and is designed to assist your local or HP - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 76
support tools platform that enables users to troubleshoot a system that cannot be tested using online tools. These may be accessed through the HP specific hardware module. To run ODE from the HP IPF Offline Diagnostics and Utilities DVD: Step 1. Insert the CD into the DVD drive and reset system power - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 77
the Support Plus: Diagnostics User's Guide, and elsewhere, as appropriate. Using Offline Diagnostic Tools There are three offline Diagnostic tools you can use to troubleshoot your hp Integrity rx1620 Server: • E-DiagTools-available on the IPF Offline Diagnostics and Utilities CD and the HP Service - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 78
diagnostic menu, launch ODE. Recommended Cleaning Procedures Suggested cleaning procedures for the hp Integrity rx1620 Server are provided in the following table. Be sure to turn off power to the server when cleaning it. Table 4-26 Cleaning Component Keyboard Monitor screen Mouse Cooling fans - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 79
Warranty and Technical Support Guide or visit us at http://www.hp.com/go/bizsupport. On our web page, enter the server model number (rx1620) and search the field. The following information is available on this web site: • Software and firmware updates • The latest drivers and utilities • Additional - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 80
Troubleshooting Where to Get Help Phone Support To contact HP customer support by phone, go to the HP IT Resource Center (ITRC) near you, at http://www.itrc.hp.com. Local phone numbers are listed in your native language for help. 80 Chapter 4 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 81
Connections AC Input Power The hp Integrity rx1620 Server comes with one power supply with a single AC input connector. The input for the connector is rated for 100 to 240 VAC at 13 Amps. WARNING Voltage is present at various locations within the server whenever an AC power source is connected - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 82
available whenever the system is connected to a power source, even if the hp Integrity rx1620 Server main power switch is in the off position. Access to the management processor can be restricted by user accounts. User accounts can be password protected and provide a specific level of access to the - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 83
installed correctly • Setting the LAN IP addresses Setting Terminal Parameters After powering Step 7. Select a supported terminal type. The Network Access to the Management Processor By connecting the management processor LAN port to an active network at the rear of the server. Step 2. Connect a - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 84
Windows. Consult your operating system documentation for more installation no user account network name, the management processor IP address, the management processor subnet mask, the management processor gateway address, and the web console be required for future troubleshooting. Figure 5-2 The - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 85
IP address. Step 5. Confirm the new address. Step 6. Enter the management processor Network Name. This is the host name for the management processor LAN. The name can be buffer Display Console history Certificate Generator Return to Redirected Console Mode Connect to another service processor Chapter - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 86
Display date Default Configuration Display FRUID Disconnect Remote or LAN Console MP Firmware upgrade Display Help for Menu or Command System Information Reset Modem Status Remote Power Control Configure Paging Power Restore Policy Configuration Power Management Module Status Reset Users 86 Chapter 5 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 87
External Core I/O Connections Table 5-1 Management Processor Commands and Descriptions (Continued) Command Description UC VT VFP WHO XD User Configuration Display software trace Virtual Front Panel Display Connected management processor Users MP Diagnostics and/or Reset Chapter 5 87 - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 88
to the installed operating system. If autoboot is not enabled, the system will enter the EFI Boot Manager. The EFI Boot Manager allows you to control the server's booting environment. For more information about the EFI Boot Manager, review the Utilities chapter of the Operations Guide. 88 Chapter - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 89
, 42 memory chip spare function, 35 Index DIMM locations, 35 installing additional, 34 supported sizes, 34 O ODE, 73, 76 Offline Diagnostics Environment, 73, 76 Offline Diagnostics Environment (ODE), 73 P PCI cards installing additional, 38 PCI slot full size, 38 half size, 38 Power, 56 Power and - HP Integrity rx1620 | Installation Guide, Second Edition - HP Integrity rx1620 - Page 90